| ▶ 계측기기 |
| EN 61010-1:2010+A1:2019 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements [Exception] 6.7.1.3 CREEPAGE DISTANCES -The test for tracking index 6.8.3.3 Impulse voltage test 9.3.2 Constructional requirements - Flammability tests 10.5.3 Insulating materials 2) The Vicat softening test of ISO 306, method A120 11.6 Specially protected equipment 11.7 Fluid pressure & leakage 12.2 Equipment producing ionizing radiation 12.3 Ultraviolet (UV) radiation 12.4 Microwave Radiation 12.5 Sonic and ultrasonic pressure 12.6 Laser sources 13.2.3 Implosion of cathode ray tubes 14.7 Printed wiring boards - Flammability tests 14.8 Circuits or components used as TRANSIENT OVERVOLTAGE limiting devices Annex G Leakage and rupture from fluids under pressure Annex H Qualification of conformal coatings for protection against pollution |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ |
소재지 |
| EN IEC 61010-2-010:2020 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-010: Particular requirements for laboratory equipment for the heating of materials |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ |
소재지 |
| EN IEC 61010-2-051:2021+A11:2021 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-051: Particular requirements for laboratory equipment for mixing and stirring |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지 |
| EN IEC 61010-2-081:2020 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지 |
| EN IEC 61010-2-201:2018 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-201: Particular requirements for control equipment [Exception] 4.4.1.101 Switching devices tests |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ |
소재지 |
| IEC 61010-1:2010+A1:2016 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements [Exception] 6.7.1.3 CREEPAGE DISTANCES -The test for tracking index 6.8.3.3 Impulse voltage test 9.3.2 Constructional requirements - Flammability tests 10.5.3 Insulating materials 2) The Vicat softening test of ISO 306, method A120 11.6 Specially protected equipment 11.7 Fluid pressure & leakage 12.2 Equipment producing ionizing radiation 12.3 Ultraviolet (UV) radiation 12.4 Microwave Radiation 12.5 Sonic and ultrasonic pressure 12.6 Laser sources 13.2.3 Implosion of cathode ray tubes 14.7 Printed wiring boards - Flammability tests 14.8 Circuits or components used as TRANSIENT OVERVOLTAGE limiting devices Annex G Leakage and rupture from fluids under pressure Annex H Qualification of conformal coatings for protection against pollution |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ |
소재지 |
| IEC 61010-2-010:2019 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-010: Particular requirements for laboratory equipment for the heating of materials |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ |
소재지 |
| IEC 61010-2-051:2018 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-051: Particular requirements for laboratory equipment for mixing and stirring |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지 |
| IEC 61010-2-081:2019 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지 |
| IEC 61010-2-201:2017 |
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-201: Particular requirements for control equipment [Exception] 4.4.1.101 Switching devices tests |
Input voltage(AC): Max. 500 V, (DC): Max. 60 V, Input Frequency: (50/60) Hz, Leakage current: Max. 500 mA, Dielectric strength test: Max. 5 kV, Humidity: Max. 95 % R.H. Earth continuity: 60 A, Temperature: Max. 200 ℃ |
소재지 |
| ▶ 산업용 전기기기 |
| EN 60204-1:2018 |
Safety of machinery-Electrical equipment of machines Part 1 : General requirements 18.2.2 Test 1 - Verification of the continuity of the protective bonding circuit 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit : (0.2 ~ 10) A Insulation resistance : DC 500 V, (1 ~ 190) ㏁ Voltage test : AC (1 ~ 5) kV Protection against residual voltage : Max. 500 V |
소재지 |
| IEC 60204-1:2016+AMD1:2021 |
Safety of machinery-Electrical equipment of machines Part 1 : General requirements 18.2.2 Test 1 - Verification of the continuity of the protective bonding circuit 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit : (0.2 ~ 10) A Insulation resistance : DC 500 V, (1 ~ 190) ㏁ Voltage test : AC (1 ~ 5) kV Protection against residual voltage : Max. 500 V |
소재지 |
| KS C IEC 60204-1:2016 |
기계류의 안전성-기계의 전기장비-제1부:일반요구사항 18.2.2 시험 1 - 보호 접지 회로의 연속성 검증 18.3 절연 저항 시험 18.4 전압 시험 18.5 잔류 전압 보호 |
보호본딩회로의 연속성 검증 : (0.2 ~ 10) A 절연저항 : DC 500 V, (1 ~ 190) ㏁ 전압시험 : AC (1 ~ 5) kV 잔류 전압에 대한 보호 : 최대 500 V |
소재지 |
| NFPA 79:2021 |
Electrical Standard for Industrial Machinery 18.2 Continuity of the Effective Ground-Fault Current Path 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit : (0.2 ~ 10) A Insulation resistance : DC 500 V, (1 ~ 900) ㏁ Voltage test : AC (1 ~ 5) kV Protection against residual voltage : Max. 500 V |
소재지 |
| NFPA 79:2024 |
Electrical Standard for Industrial Machinery 18.2 Continuity of the Effective Ground-Fault Current Path 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit : (0.2 ~ 10) A Insulation resistance : DC 500 V, (1 ~ 900) ㏁ Voltage test : AC (1 ~ 5) kV Protection against residual voltage : Max. 500 V |
소재지 |
| SEMI S2-0724 |
ENVIRONMENTAL, HEALTH, AND SAFETY GUIDELINE FOR SEMICONDUCTOR MANUFACTURING EQUIPMENT 13.6.2 Earthing Continuity and Continuity of the Protectvie Bonding Circuit Test |
Continuity of the protective bonding circuit : (0.2 ~ 10) A |
소재지 |
| SEMI S2-0821 |
ENVIRONMENTAL, HEALTH, AND SAFETY GUIDELINE FOR SEMICONDUCTOR MANUFACTURING EQUIPMENT 13.6.2 Earthing Continuity and Continuity of the Protectvie Bonding Circuit Test |
Continuity of the protective bonding circuit : (0.2 ~ 10) A |
소재지 |
| SEMI S22-0718E |
SAFETY GUIDELINE FOR THE ELECTRICAL DESIGN OF SEMICONDUCTOR MANUFACTURING EQUIPMENT 22.3 Earthing Continuity and Continuity of the Protectvie Bonding Circuit Test , 22.6 Dielectric Test |
Continuity of the protective bonding circuit : (0.2 ~ 10) A, Dielectric Test : AC (1 ~ 5) kV |
소재지 |
| 고용노동부 고시 제2020-37호(2020.01.15) |
위험기계-기구 자율안전확인 고시(접지연속성 시험, 절연저항 시험, 내전압 시험, 잔류전압 시험) 제2장 연삭기 또는 연마기 별표 1의 제37호 시험, 제3장 산업용 로봇 별표 2의 제36호 시험, 제4장 혼합기 별표 3의 제26호 시험, 제5장 파쇄기 또는 분쇄기 별표 4의 제29호 시험, 제6장 식품가공기계(파쇄-절단-혼합-제면기) 별표 5의 제67호 시험, 제7장 컨베이어 별표 6의 제39호 시험, 제8장 자동차정비용 리프트 별표 7의 제36호 시험, 제9장 공작기계(선반, 드릴기, 평삭-형삭기, 밀링) 별표 8의 제99호 시험, 제10장 목재가공기계(둥근톱, 대패, 루타기, 띠톱, 모떼기 기계) 별표 9의 제92호 시험, 제11장 인쇄기 별표 10의 제38호 시험 |
보호본딩회로의 연속성 검증 : (0.2 ~ 10) A 절연저항 : DC 500 V, (1 ~ 900) ㏁ 전압시험 : AC (1 ~ 5) kV 잔류 전압에 대한 보호 : 최대 500 V |
소재지 |
| ▶ 전자기적합성 |
| CISPR 11:2015+A1:2016+A2:2019 |
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics - Limits and methods of measurement (Exception)Radiated emission |
CE : 150 ㎑ ~ 30 ㎒ 1 Phase 90 V ~ 270 V, 36 A |
소재지 |
| CISPR 11:2024 |
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics - Limits and methods of measurement (Exception)Radiated emission |
CE : 150 ㎑ ~ 30 ㎒ 1 Phase 90 V ~ 270 V, 36 A |
소재지 |
| EN 55011:2016+A11:2020 |
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics - Limits and methods of measurement (Exception) radiated emission |
CE : 150 ㎑ ~ 30 ㎒ 1 Phase 90 V ~ 270 V, 36 A |
소재지 |
| EN 55011:2016+A2:2021 |
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception:radiated emission] |
CE : 150 ㎑ ~ 30 ㎒ 1 Phase 90 V ~ 270 V, 36 A
|
소재지 |
| EN 61000-4-11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
0 % ~ 100 %, below 16A |
소재지 |
| EN 61000-4-2:2009 |
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
MAX ±8 ㎸ |
소재지 |
| EN 61000-4-4:2012 |
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
MAX ± 4 ㎸ |
소재지 |
| EN 61000-4-5:2014 |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques – Surge immunity test (Exception) - 6.3.3) Coupling/decoupling networks for interconnection lines - Annex A |
Max ±4 ㎸ |
소재지 |
| EN 61000-4-5:2014/A1:2017 |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques – Surge immunity test |
Max ±4 ㎸ |
소재지 |
| EN 61000-4-6:2014 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
Frequency: 150 ㎑ ~ 80 ㎒, less than 10 V |
소재지 |
| EN 61000-4-6:2023 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
Frequency: 150 ㎑ ~ 80 ㎒, less than 10 V |
소재지 |
| EN 61000-6-2:2019 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards – Immunity standard for Industrial environments (Exception) Power-frequency magnetic field, Radio-frequency electromagnetic field(Amplitude modulated) |
Electrostatic discharge : MAX ±8 ㎸, Fast transients : MAX ±4 ㎸, Surges : MAX ±4 ㎸, Radio-frequency common mode : 150 ㎑ ~ 80 ㎒, less than 10 V, Voltage dips, Voltage interruptions : 0 % ~ 100 %, below 16 A |
소재지 |
| EN 61000-6-4:2019 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments (Exception)Radiated disturbances. |
CE : 150 ㎑ ~ 30 ㎒ 1 Phase 90 V ~ 270 V, 36 A |
소재지 |
| IEC 61000-4-11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
0 % ~ 100 %, below 16A |
소재지 |
| IEC 61000-4-2:2008 |
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
MAX ±8 ㎸ |
소재지 |
| IEC 61000-4-4:2012 |
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
MAX ± 4 ㎸ |
소재지 |
| IEC 61000-4-5:2014 |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques – Surge immunity test [Exception: - 6.3.3) Coupling/decoupling networks for interconnection lines - Annex A] |
Max ±4 ㎸ |
소재지 |
| IEC 61000-4-5:2014/A1:2017 |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques – Surge immunity test |
Max ±4 ㎸ |
소재지 |
| IEC 61000-4-6:2013 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
Frequency: 150 ㎑ ~ 80 ㎒, less than 10 V |
소재지 |
| IEC 61000-4-6:2023 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
Frequency: 150 ㎑ ~ 80 ㎒, less than 10 V |
소재지 |
| IEC 61000-6-2:2016 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards – Immunity standard for Industrial environments (Exception) Power-frequency magnetic field, Radio-frequency electromagnetic field(Amplitude modulated) |
Electrostatic discharge : MAX ±8 ㎸, Fast transients : MAX ±4 ㎸, Surges : MAX ±4 ㎸, Radio-frequency common mode : 150 ㎑ ~ 80 ㎒, less than 10 V, Voltage dips, Voltage interruptions : 0 % ~ 100 %, below 16 A |
소재지 |
| IEC 61000-6-4:2018 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments (Exception)Radiated disturbances. |
CE : 150 ㎑ ~ 30 ㎒ 1 Phase 90 V ~ 270 V, 36 A |
소재지 |
| KS C 9610-4-11:2020 |
전자파적합성(EMC) - 제 4-11부: 시험 및 측정 기술 - 전압 강하, 순간 정전, 전압 변동 내성 시험 |
0 % ~ 100 %, 16 A 미만 |
소재지 |
| KS C 9610-4-2:2017 |
전자파적합성(EMC) - 제 4-2부: 시험 및 측정 기술 - 정전기 방전 내성 시험 |
최대 ±8 ㎸ |
소재지 |
| KS C 9610-4-4:2020 |
전자파적합성(EMC) - 제 4-4부: 시험 및 측정 기술 - 전기적 빠른 과도현상, 버스트 내성 시험 |
최대 ±4 ㎸ |
소재지 |
| KS C 9610-4-5:2023 |
전자파적합성(EMC) - 제 4-5부: 시험 및 측정 기술 - 서지 내성 시험 (제외항목) - 6.3.3 상호접속선로에 대한 결합/감결합 회로망 - 부속서 A |
최대 ±4 ㎸ |
소재지 |
| KS C 9610-4-6:2020 |
전자파적합성(EMC) - 제 4-6부: 시험 및 측정 기술 - 전도성 RF 전자기장 내성 시험 |
0.15 ㎒ ~ 80 ㎒, 10 V 이하 |
소재지 |
| KS C 9811:2019 |
산업, 과학, 의료용(ISM) 기기 - 무선 주파수 방해 특성 - 허용기준 및 측정방법 (제외)전자파 방사성 방해 |
전도성 방해 전압 : 150 ㎑ ~ 30 ㎒, 단상 90 V ~ 270 V, 36 A |
소재지 |
| S2-W-5:2024 |
기계·기구 등에 관한 공통 기술기준[전자파분야] (제외항목) 방사장해시험, 방사내성시험 |
전도장해시험 : 150 ㎑ ~ 30 ㎒, 정전기 방전 내성시험 : 최대 ±8 ㎸, 전기적빠른과도현상시험 : 최대 ±2 ㎸, 서지내성시험 : 최대 ±2 ㎸, 전도내성시험 : 150 ㎑ ~ 1 000 ㎒, 10 V 이하, 전압변동, 순간전압강하 및 순간 정전 내성시험 : 0 % ~ 100 %, 16 A 미만 |
소재지 |