| ▶ 전자기적합성 |
| MIL-STD-461F:2007 |
Requirements for the control of electromagnetic interference characteristics of subsystems and equipment 4. General requirements 5.4 CE101, conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, conducted emissions, power leads, 10 kHz to 10 MHz 5.6 CE106, conducted emissions, antenna terminals, 10 kHz to 40 GHz 5.7 CS101, conducted susceptibility, power leads, 30 Hz to 150 kHz 5.8 CS103, conducted susceptibility, antenna port, intermodulation, 15 kHz to 10 GHz 5.9 CS104, conducted susceptibility, antenna port, rejection of undesired signals, 30 Hz to 20 GHz 5.10 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz 5.13 CS114, conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz 5.14 CS115, conducted susceptibility, bulk cable injection, impulse excitation 5.15 CS116, conducted susceptibility, damped sinusoidal transient, cable and power leads, 10 kHz to 100 MHz 5.16 RE101, radiated emissions, magnetic field, 30 Hz to 100 kHz 5.17 RE102, radiated emissions, electric field, 10 kHz to 18 GHz 5.19 RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.20 RS103, radiated susceptibility, electric field, 2 MHz to 40 GHz 5.21 RS105, radiated susceptibility, transient electromagnetic field |
EUT power capacity AC (0 ~ 440) V, 3Φ, 4 W, (0 ~ 50) A, 60 Hz AC (0 ~ 115) V, 3Φ, 4 W (0 ~ 50) A 400 Hz AC (0 ~ 220) V, 1Φ, 2 W (0 ~ 100) A, 60 Hz DC (0 ~ 40) V, 2 W (0 ~ 128) A 5.4 CE101, 30 Hz to 10 kHz 5.5 CE102, 10 kHz to 10 MHz 5.6 CE106, 10 kHz to 40 GHz 5.7 CS101, 30 Hz to 150 kHz 5.8 CS103, 15 kHz to 10 GHz 5.9 CS104, 30 Hz to 20 GHz 5.10 CS105, 30 Hz to 20 GHz 5.13 CS114, 4 kHz to 200 MHz 5.14 CS115, 30 Hz, rated 5 A 5.15 CS116, 10 kHz, 100 kHz , 1 MHz, 10 MHz, 30 MHz, 100 MHz 5.16 RE101, 30 Hz to 100 kHz 5.17 RE102, 10 kHz to 18 GHz 5.19 RS101, 30 Hz to 100 kHz 5.20 RS103, 2 MHz to 18 GHz, (0 ~ 60) V/m 5.21 RS105, 50 kV/m |
소재지 |
| MIL-STD-464C:2010 |
ELECTROMAGNETIC ENVIRONMENTAL EFFECTS REQUIREMENTS FOR SYSTEM 5.1 Margins 5.2 Intra-system electromagnetic compatibility (EMC) 5.11 Electrical bonding 5.12 External grounds |
Margins : safety critical & mission Bonding : min. 1 mΩ |
소재지 |
| MIL-STD-331D: 2017 |
FUZES, IGNITION SAFETY DEVICES AND OTHER RELATED COMPONENTS, ENVIRONMENTAL AND PERFORMANCE TESTS FOR 5.2.6 Group F - Electric and Magnetic Influence Tests. Appendix F Test F2 High Altitude Electromagnetic Pulse |
50 kV/m |
소재지 |
| IEEE Std 1502: 2020 |
IEEE Recommended Practice for Radar Cross-Section Test Procedures 3.3.1 Indoor compact range |
8 GHz ~ 18 GHz |
소재지 |
| IEEE Std 1128: 1998 |
IEEE Recommended Practice for Radio-Frequency (RF) Absorber Evaluation in the Range of 30 MHz to 5 GHz 7.2.1 The arch method measurment procedure |
1 GHz ~ 5 GHz |
소재지 |
| IEEE-STD-299:2006 |
IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures |
Shielding Effectiveness, 9 kHz to 18 GHz |
소재지 |
| MIL-STD-188-125-2 : 1999 |
HIGH-ALTITUDE ELECTROMAGNETIC PULSE(HEMP) PROTECTION FOR GROUND-BASED C4l FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS Part 2. TRANSPORTABLE SYSTEMS 5.3 Subsystem HEMP shields |
Subsystem HEMP shields, 10 kHz to 1 GHz |
소재지 |
| MIL-STD-188-125-1 : 1998 |
HIGH-ALTITUDE ELECTROMAGNETIC PULSE(HEMP) PROTECTION FOR GROUND-BASED C4l FACILITIES PERFORMING CRITICAL, TIME-URGENT MISSIONS PART 1. FIXED FACILITIES 5.3 Facility HEMP shield |
Facility HEMP shield, 10 kHz to 1 GHz |
소재지 |
| MIL-STD-461D : 1993 |
Requirements for the control of electromagnetic interference emissions and susceptibility 5.3.1 CE101, Conducted Emissions, Power Leads, 30 Hz to 10 kHz 5.3.2 CE102, Conducted Emissions, Power Leads, 10 kHz to 10 MHz 5.3.3 CE106, Conducted Emissions, Antenna Terminal, 10 kHz to 40 GHz 5.3.4 CS101, Conducted Susceptibility, Power Leads, 30 Hz to 50 kHz 5.3.5 CS103, Conducted Susceptibility, Antenna Port, Intermodulation, 15 kHz to 10 GHz 5.3.6 CS104, Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals, 30 Hz to 20 GHz 5.3.7 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz 5.3.9 CS114, Conducted Susceptibility, Bulk Cable Injection, 10 kHz to 400 MHz 5.3.10 CS115, Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation 5.3.11 CS116, Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz 5.3.12 RE101, Radiated Emissions, Magnetic Field, 30 Hz to 100 kHz 5.3.13 RE102, Radiated Emissions, Electric Field, 10 kHz to 18 GHz 5.3.15 RS101, Radiated Susceptibility, Magnetic Field, 30 Hz to 100 kHz 5.3.16 RS103, Radiated Susceptibility, Electric Field, 10 kHz to 40 GHz 5.3.17 RS105, radiated susceptibility, transient electromagnetic field |
EUT 전원 용량 AC (0 ~ 440) V, 3Φ, 4 W (0 ~ 50) A, 60 Hz AC (0 ~ 115) V, 3Φ, 4 W (0 ~ 50) A, 400 Hz AC (0 ~ 220) V, 1Φ, 2 W (0 ~ 100) A, 60 Hz DC (0 ~ 40) V, 2 W (0 ~ 128) A 5.3.1 CE101, 30 ㎐ to 10 ㎑ 5.3.2 CE102, 10 ㎑ to 10 ㎒ 5.3.3 CE106, 10 ㎑ to 40 ㎓ 5.3.4 CS101, 30 ㎐ to 150 ㎑ 5.3.5 CS103, 15 ㎑ to 10 ㎓ 5.3.6 CS104, 30 ㎐ to 20 ㎓ 5.3.7 CS105, 30 ㎐ to 20 ㎓ 5.3.9 CS114, 10 ㎑ to 400 ㎒ 5.3.10 CS115, 30 ㎐ rate, 5 A 5.3.11 CS116, 10 ㎑, 100 ㎑ , 1 ㎒, 10 ㎒, 30 ㎒, 100 ㎒ 5.3.12 RE101, 30 ㎐to 100 k㎐ 5.3.13 RE102, 10 ㎑ to 18 ㎓ 5.3.15 RS101, 30 ㎐ to 100 ㎑ 5.3.16 RS103, 10 ㎑ to 18 ㎓, 0 ~ 60 V/m 5.3.17 RS105, 50 kV/m |
소재지 |
| MIL-STD-462D : 1993 |
Test method standard for measurement of electromagnetic interference characteristics 5. Measurement procedures CE101, conducted emissions, power leads, 30 Hz to 10 kHz CE102, conducted emissions, power leads, 10 kHz to 10 MHz CE106, conducted emissions, antenna terminal, 10 kHz to 40 GHz CS101, conducted susceptibility, power leads, 30 Hz to 50 kHz CS103, conducted susceptibility, antenna port, intermodulation, 15 kHz to 10 GHz CS104, conducted susceptibility, antenna port, rejection of undesired signals, 30 kHz to 20 GHz CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz CS114, conducted susceptibility, bulk cable injection, 10 kHz to 400 MHz CS115, conducted susceptibility, bulk cable injection, impulse excitation CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz RE101, radiated emissions, magnetic Ffeld, 30 Hz to 100 kHz RE102, radiated emissions, electric Field, 10 kHz to 18 GHz RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz RS103, radiated susceptibility, electric field, 10 kHz to 40 GHz RS105, radiated susceptibility, transient electromagnetic field |
EUT 전원 용량 AC (0 ~ 440) V, 3Φ, 4 W (0 ~ 50) A, 60 Hz AC (0 ~ 115) V, 3Φ, 4 W (0 ~ 50) A, 400 Hz AC (0 ~ 220) V, 1Φ, 2 W (0 ~ 100) A, 60 Hz DC (0 ~ 40) V, 2 W (0 ~ 128) A CE101, 30 ㎐ to 10 ㎑ CE102, 10 ㎑ to 10 ㎒ CE106, 10 ㎑ to 40 ㎓ CS101, 30 ㎐ to 150 ㎑ CS103, 15 ㎑ to 10 ㎓ CS104, 30 ㎐ to 20 ㎓ CS105, 30 ㎐ to 20 ㎓ CS114, 10 ㎑ to 400 ㎒ CS115, 30 ㎐ rate, 5 A CS116, 10 ㎑, 100 ㎑ ,1 ㎒, 10 ㎒, 30 ㎒, 100 ㎒ RE101, 30 ㎐ to 100 k㎐ RE102, 10 ㎑ to 18 ㎓ RS101, 30 ㎐ to 100 ㎑ RS103 , 10 ㎑ to 18 ㎓, 0 ~ 60 V/m RS105, 50 kV/m |
소재지 |
| MIL-STD-461G : 2015 |
Requirements for the control of electromagnetic interference characteristics of subsystems and equipment 5.4 CE101, Conducted Emissions, Power Leads, 30 Hz to 10 kHz 5.5 CE102, Conducted Emissions, Power Leads, 10 kHz to 10 MHz 5.6 CE106, Conducted Emissions, Antenna Terminal, 10 kHz to 40 GHz 5.7 CS101, Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz 5.8 CS103, Conducted Susceptibility, Antenna Port, Intermodulation, 15 kHz to 10 GHz 5.9 CS104, Conducted Susceptibility, Antenna Port, Rejection of Undesired Signals, 30 Hz to 20 GHz 5.10 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz 5.13 CS114, Conducted Susceptibility, Bulk Cable Injection, 10 kHz to 200 MHz 5.14 CS115, Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation 5.15 CS116, Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads, 10 kHz to 100 MHz 5.16 CS118, Conducted Susceptibility, Personnel Borne Electrostatic Discharge 5.17 RE101, Radiated Emissions, Magnetic Field, 30 Hz to 100 kHz 5.18 RE102, Radiated Emissions, Electric Field, 10 kHz to 18 GHz 5.20 RS101, Radiated Susceptibility, Magnetic Field, 30 Hz to 100 kHz 5.21 RS103, Radiated Susceptibility, Electric Field, 2 MHz to 40 GHz 5.22 RS105, radiated susceptibility, transient electromagnetic field |
EUT 전원 용량 AC (0 ~ 440) V, 3Φ, 4 W (0 ~ 50) A, 60 Hz AC (0 ~ 115) V, 3Φ, 4 W (0 ~ 50) A, 400 Hz AC (0 ~ 220) V, 1Φ, 2 W (0 ~ 100) A, 60 Hz DC (0 ~ 40) V, 2 W (0 ~ 128) A 5.4 CE101, 30 Hz to 10 kHz 5.5 CE102, 10 kHz to 10 MHz 5.6 CE106, 10 kHz to 40 GHz 5.7 CS101, 30 Hz to 150 ㎑ 5.8 CS103, 15 kHz to 10 GHz 5.9 CS104, 30 Hz to 20 GHz 5.10 CS105, 30 Hz to 20 GHz 5.12 CS114, 4 kHz to 200 MHz 5.13 CS115, 30 Hz rate, 5 A 5.14 CS116, 10 kHz, 100 kHz , 1 MHz, 10 MHz, 30 MHz, 100 MHz 5.16 CS118 접촉방전 Max 10 kV, 기중방전 Max 15 kV 5.17 RE101, 30 Hz to 100 kHz 5.18 RE102, 10 kHz to 18 GHz 5.20 RS101, 30 Hz to 100 kHz 5.21 RS103, 2 MHz to 18 GHz, 0 ~ 60 V/m 5.22 RS105, 50 kV/m |
소재지 |
| MIL-STD-461E : 1999 |
Requirements for the control of electromagnetic interference characteristics of subsystems and equipment 5.4 CE101, conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, conducted emissions, power leads, 10 kHz to 10 MHz 5.6 CE106, conducted emissions, antenna terminal, 10 kHz to 40 GHz 5.7 CS101, conducted susceptibility, power leads, 30 Hz to 150 kHz 5.8 CS103, conducted susceptibility, antenna port, intermodulation, 15 kHz to 10 GHz 5.9 CS104, conducted susceptibility, antenna port, rejection of undesired signals, 30 Hz to 20 GHz 5.10 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz 5.12 CS114, conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz 5.13 CS115, conducted susceptibility, bulk cable injection, impulse excitation 5.14 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.15 RE101, radiated emissions, magnetic field, 30 Hz to 100 kHz 5.16 RE102, radiated emissions, electric field, 10 kHz to 18 GHz 5.18 RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.19 RS103, radiated susceptibility, electric field, 2 MHz to 40 GHz 5.20 RS105, radiated susceptibility, transient electromagnetic field |
EUT 전원 용량 AC (0 ~ 440) V, 3Φ, 4 W (0 ~ 50) A, 60 Hz AC (0 ~ 115) V, 3Φ, 4 W (0 ~ 50) A, 400 Hz AC (0 ~ 220) V, 1Φ, 2 W (0 ~ 100) A, 60 Hz DC (0 ~ 40) V, 2 W (0 ~ 128) A 5.4 CE101, 30 Hz to 10 kHz 5.5 CE102, 10 kHz to 10 MHz 5.6 CE106, 10 kHz to 40 GHz 5.7 CS101, 30 Hz to 150 kHz 5.8 CS103, 15 kHz to 10 GHz 5.9 CS104, 30 Hz to 20 GHz 5.10 CS105, 30 Hz to 20 GHz 5.12 CS114, 10 kHz to 200 MHz 5.13 CS115, 30 Hz, rated 5 A 5.14 CS116, 10 kHz, 100 kHz , 1 MHz, 10 MHz, 30 MHz, 100 MHz 5.15 RE101, 30 Hz to 100 kHz 5.16 RE102, 10 kHz to 18 GHz 5.18 RS101, 30 Hz to 100 kHz 5.19 RS103, 2 MHz to 18 GHz, (0 ~ 60) V/m 5.20 RS105, 50 kV/m |
소재지 |
| MIL-STD-464D:2020 |
ELECTROMAGNETIC ENVIRONMENTAL EFFECTS REQUIREMENTS FOR SYSTEM 5.1 Margins 5.2 Intra-system electromagnetic compatibility (EMC) 5.11 Electrical bonding 5.12 External grounds |
Margins : safety critical & mission Bonding : min. 1 mΩ |
소재지 |