home검색서비스>시험기관검색

시험기관검색KOLAS Search Service

시험은 특정한 제품,공정 또는 서비스를 대상으로 하나 또는 그 이상의 특성을 규정된 절차에 따라 측정하는 기술적인 작업, 설계, 제품, 서비스, 공정, 공장에 대한 조사 및 특정요건이나 전문적 판정, 일반요건을 근거로 한 적합성 판정을 말한다.

인정번호 (Accreditation No) KT590
기관명
(Organization Name)
주식회사 케이이알
공인유효기간 2026-02-03 ~ 2030-02-02
주소 세종특별자치시 연동면 원합강1길 50
소재지 세종특별자치시 연동면 원합강1길 50
담당자 김한식
전화 번호 042-825-9988
팩스 번호 044-863-9812
인정범위 전기시험
규격번호
(Test method)
규격명
(Standard designation)
시험범위
(Test Range)
사업장
(Site)
▶ 전자기적합성
MIL-STD-461F:2007 Requirements for the control of
electromagnetic interference characteristics
of subsystems and equipment
4. General requirements
5.4 CE101, conducted emissions, power
leads, 30 Hz to 10 kHz
5.5 CE102, conducted emissions, power
leads, 10 kHz to 10 MHz
5.6 CE106, conducted emissions, antenna
terminals, 10 kHz to 40 GHz
5.7 CS101, conducted susceptibility, power
leads, 30 Hz to 150 kHz
5.8 CS103, conducted susceptibility,
antenna port, intermodulation, 15 kHz
to 10 GHz
5.9 CS104, conducted susceptibility,
antenna port, rejection of undesired
signals, 30 Hz to 20 GHz
5.10 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz
5.13 CS114, conducted susceptibility, bulk
cable injection, 10 kHz to 200 MHz
5.14 CS115, conducted susceptibility, bulk
cable injection, impulse excitation
5.15 CS116, conducted susceptibility,
damped sinusoidal transient, cable
and power leads, 10 kHz to 100
MHz
5.16 RE101, radiated emissions, magnetic
field, 30 Hz to 100 kHz
5.17 RE102, radiated emissions, electric
field, 10 kHz to 18 GHz
5.19 RS101, radiated susceptibility,
magnetic field, 30 Hz to 100 kHz
5.20 RS103, radiated susceptibility, electric
field, 2 MHz to 40 GHz
5.21 RS105, radiated susceptibility, transient electromagnetic field
EUT power capacity
AC (0 ~ 440) V, 3Φ, 4 W,
(0 ~ 50) A, 60 Hz
AC (0 ~ 115) V, 3Φ, 4 W
(0 ~ 50) A 400 Hz
AC (0 ~ 220) V, 1Φ, 2 W
(0 ~ 100) A, 60 Hz
DC (0 ~ 40) V, 2 W
(0 ~ 128) A
5.4 CE101, 30 Hz to 10 kHz
5.5 CE102, 10 kHz to 10
MHz
5.6 CE106, 10 kHz to 40 GHz
5.7 CS101, 30 Hz to 150 kHz
5.8 CS103, 15 kHz to 10 GHz
5.9 CS104, 30 Hz to 20 GHz
5.10 CS105, 30 Hz to 20 GHz
5.13 CS114, 4 kHz to 200
MHz
5.14 CS115, 30 Hz, rated 5 A
5.15 CS116, 10 kHz, 100 kHz
, 1 MHz, 10 MHz, 30 MHz,
100 MHz
5.16 RE101, 30 Hz to 100
kHz
5.17 RE102, 10 kHz to 18
GHz
5.19 RS101, 30 Hz to 100
kHz
5.20 RS103, 2 MHz to 18
GHz, (0 ~ 60) V/m
5.21 RS105, 50 kV/m
소재지
MIL-STD-464C:2010 ELECTROMAGNETIC
ENVIRONMENTAL EFFECTS
REQUIREMENTS FOR
SYSTEM
5.1 Margins
5.2 Intra-system
electromagnetic
compatibility (EMC)
5.11 Electrical bonding
5.12 External grounds
Margins : safety critical & mission
Bonding : min. 1 mΩ
소재지
MIL-STD-331D: 2017 FUZES, IGNITION SAFETY DEVICES AND OTHER RELATED COMPONENTS, ENVIRONMENTAL AND PERFORMANCE TESTS FOR
5.2.6 Group F - Electric and Magnetic Influence Tests. Appendix F Test F2 High Altitude Electromagnetic Pulse
50 kV/m 소재지
IEEE Std 1502: 2020 IEEE Recommended Practice for Radar Cross-Section
Test Procedures
3.3.1 Indoor compact range
8 GHz ~ 18 GHz 소재지
IEEE Std 1128: 1998 IEEE Recommended Practice for Radio-Frequency
(RF) Absorber Evaluation in the Range of 30 MHz to 5 GHz
7.2.1 The arch method measurment procedure
1 GHz ~ 5 GHz 소재지
IEEE-STD-299:2006 IEEE Standard Method for Measuring the
Effectiveness of Electromagnetic Shielding
Enclosures
Shielding Effectiveness,
9 kHz to 18 GHz
소재지
MIL-STD-188-125-2 : 1999 HIGH-ALTITUDE ELECTROMAGNETIC
PULSE(HEMP) PROTECTION FOR
GROUND-BASED C4l FACILITIES
PERFORMING CRITICAL, TIME-URGENT
MISSIONS
Part 2. TRANSPORTABLE SYSTEMS
5.3 Subsystem HEMP shields
Subsystem HEMP shields,
10 kHz to 1 GHz
소재지
MIL-STD-188-125-1 : 1998 HIGH-ALTITUDE ELECTROMAGNETIC
PULSE(HEMP) PROTECTION FOR
GROUND-BASED C4l FACILITIES
PERFORMING CRITICAL, TIME-URGENT
MISSIONS
PART 1. FIXED FACILITIES
5.3 Facility HEMP shield
Facility HEMP shield, 10
kHz to 1 GHz
소재지
MIL-STD-461D : 1993 Requirements for the control of
electromagnetic interference emissions and susceptibility
5.3.1 CE101, Conducted Emissions, Power
Leads, 30 Hz to 10 kHz
5.3.2 CE102, Conducted Emissions, Power
Leads, 10 kHz to 10 MHz
5.3.3 CE106, Conducted Emissions,
Antenna Terminal, 10 kHz to 40 GHz
5.3.4 CS101, Conducted Susceptibility,
Power Leads, 30 Hz to 50 kHz
5.3.5 CS103, Conducted Susceptibility,
Antenna Port, Intermodulation, 15 kHz to
10 GHz
5.3.6 CS104, Conducted Susceptibility,
Antenna Port, Rejection of Undesired
Signals, 30 Hz to 20 GHz
5.3.7 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz
5.3.9 CS114, Conducted Susceptibility, Bulk
Cable Injection, 10 kHz to 400 MHz
5.3.10 CS115, Conducted Susceptibility,
Bulk Cable Injection, Impulse Excitation
5.3.11 CS116, Conducted Susceptibility,
Damped Sinusoidal Transients, Cables
and Power Leads, 10 kHz to 100 MHz
5.3.12 RE101, Radiated Emissions,
Magnetic Field, 30 Hz to 100 kHz
5.3.13 RE102, Radiated Emissions, Electric
Field, 10 kHz to 18 GHz
5.3.15 RS101, Radiated Susceptibility,
Magnetic Field, 30 Hz to 100 kHz
5.3.16 RS103, Radiated Susceptibility,
Electric Field, 10 kHz to 40 GHz
5.3.17 RS105, radiated susceptibility, transient electromagnetic field
EUT 전원 용량
AC (0 ~ 440) V, 3Φ, 4 W
(0 ~ 50) A, 60 Hz
AC (0 ~ 115) V, 3Φ, 4 W
(0 ~ 50) A, 400 Hz
AC (0 ~ 220) V, 1Φ, 2 W
(0 ~ 100) A, 60 Hz
DC (0 ~ 40) V, 2 W
(0 ~ 128) A
5.3.1 CE101, 30 ㎐ to 10 ㎑
5.3.2 CE102, 10 ㎑ to 10 ㎒
5.3.3 CE106, 10 ㎑ to 40 ㎓
5.3.4 CS101, 30 ㎐ to 150 ㎑
5.3.5 CS103, 15 ㎑ to 10 ㎓
5.3.6 CS104, 30 ㎐ to 20 ㎓
5.3.7 CS105, 30 ㎐ to 20 ㎓
5.3.9 CS114, 10 ㎑ to 400 ㎒
5.3.10 CS115, 30 ㎐ rate, 5 A
5.3.11 CS116, 10 ㎑, 100 ㎑
, 1 ㎒, 10 ㎒, 30 ㎒, 100 ㎒
5.3.12 RE101, 30 ㎐to 100 k㎐
5.3.13 RE102, 10 ㎑ to 18 ㎓
5.3.15 RS101, 30 ㎐ to 100 ㎑
5.3.16 RS103, 10 ㎑ to 18 ㎓,
0 ~ 60 V/m
5.3.17 RS105, 50 kV/m
소재지
MIL-STD-462D : 1993 Test method standard for measurement
of electromagnetic interference
characteristics
5. Measurement procedures
CE101, conducted emissions, power leads,
30 Hz to 10 kHz
CE102, conducted emissions, power leads,
10 kHz to 10 MHz
CE106, conducted emissions, antenna
terminal, 10 kHz to 40 GHz
CS101, conducted susceptibility, power
leads, 30 Hz to 50 kHz
CS103, conducted susceptibility, antenna
port, intermodulation, 15 kHz to 10 GHz
CS104, conducted susceptibility, antenna
port, rejection of undesired
signals, 30 kHz to 20 GHz
CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz
CS114, conducted susceptibility, bulk
cable injection, 10 kHz to 400 MHz
CS115, conducted susceptibility, bulk
cable injection, impulse excitation
CS116, conducted susceptibility, damped
sinusoidal transients, cables and power
leads, 10 kHz to 100 MHz
RE101, radiated emissions, magnetic Ffeld,
30 Hz to 100 kHz
RE102, radiated emissions, electric Field,
10 kHz to 18 GHz
RS101, radiated susceptibility, magnetic
field, 30 Hz to 100 kHz
RS103, radiated susceptibility, electric
field, 10 kHz to 40 GHz
RS105, radiated susceptibility, transient electromagnetic field
EUT 전원 용량
AC (0 ~ 440) V, 3Φ, 4 W
(0 ~ 50) A, 60 Hz
AC (0 ~ 115) V, 3Φ, 4 W
(0 ~ 50) A, 400 Hz
AC (0 ~ 220) V, 1Φ, 2 W
(0 ~ 100) A, 60 Hz
DC (0 ~ 40) V, 2 W
(0 ~ 128) A
CE101, 30 ㎐ to 10
㎑
CE102, 10 ㎑ to 10
㎒
CE106, 10 ㎑ to 40
㎓
CS101, 30 ㎐ to 150
㎑
CS103, 15 ㎑ to 10
㎓
CS104, 30 ㎐ to 20
㎓
CS105, 30 ㎐ to 20
㎓
CS114, 10 ㎑ to 400
㎒
CS115, 30 ㎐ rate, 5
A
CS116, 10 ㎑, 100 ㎑
,1 ㎒,
10 ㎒, 30 ㎒, 100 ㎒
RE101, 30 ㎐ to 100
k㎐
RE102, 10 ㎑ to 18
㎓
RS101, 30 ㎐ to 100
㎑
RS103 , 10 ㎑ to 18 ㎓,
0 ~ 60 V/m
RS105, 50 kV/m
소재지
MIL-STD-461G : 2015 Requirements for the control of electromagnetic
interference characteristics of subsystems and
equipment
5.4 CE101, Conducted Emissions, Power Leads,
30 Hz to 10 kHz
5.5 CE102, Conducted Emissions, Power Leads,
10 kHz to 10 MHz
5.6 CE106, Conducted Emissions, Antenna
Terminal, 10 kHz to 40 GHz
5.7 CS101, Conducted Susceptibility, Power
Leads, 30 Hz to 150 kHz
5.8 CS103, Conducted Susceptibility, Antenna
Port, Intermodulation, 15 kHz to 10 GHz
5.9 CS104, Conducted Susceptibility, Antenna
Port, Rejection of Undesired Signals,
30 Hz to 20 GHz
5.10 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz
5.13 CS114, Conducted Susceptibility, Bulk
Cable Injection, 10 kHz to 200 MHz
5.14 CS115, Conducted Susceptibility, Bulk
Cable Injection, Impulse Excitation
5.15 CS116, Conducted Susceptibility,
Damped Sinusoidal Transients, Cables and
Power Leads, 10 kHz to 100 MHz
5.16 CS118, Conducted Susceptibility,
Personnel Borne Electrostatic Discharge
5.17 RE101, Radiated Emissions, Magnetic
Field, 30 Hz to 100 kHz
5.18 RE102, Radiated Emissions, Electric Field,
10 kHz to 18 GHz
5.20 RS101, Radiated Susceptibility, Magnetic
Field, 30 Hz to 100 kHz
5.21 RS103, Radiated Susceptibility, Electric
Field, 2 MHz to 40 GHz
5.22 RS105, radiated susceptibility, transient electromagnetic field
EUT 전원 용량
AC (0 ~ 440) V, 3Φ, 4 W
(0 ~ 50) A, 60 Hz
AC (0 ~ 115) V, 3Φ, 4 W
(0 ~ 50) A, 400 Hz
AC (0 ~ 220) V, 1Φ, 2 W
(0 ~ 100) A, 60 Hz
DC (0 ~ 40) V, 2 W
(0 ~ 128) A
5.4 CE101, 30 Hz to 10 kHz
5.5 CE102, 10 kHz to 10 MHz
5.6 CE106, 10 kHz to 40 GHz
5.7 CS101, 30 Hz to 150 ㎑
5.8 CS103, 15 kHz to 10 GHz
5.9 CS104, 30 Hz to 20 GHz
5.10 CS105, 30 Hz to 20 GHz
5.12 CS114, 4 kHz to 200
MHz
5.13 CS115, 30 Hz rate, 5 A
5.14 CS116, 10 kHz, 100 kHz ,
1 MHz, 10 MHz, 30 MHz, 100
MHz
5.16 CS118 접촉방전 Max 10
kV, 기중방전 Max 15 kV
5.17 RE101, 30 Hz to 100 kHz
5.18 RE102, 10 kHz to 18
GHz
5.20 RS101, 30 Hz to 100 kHz
5.21 RS103, 2 MHz to 18
GHz, 0 ~ 60 V/m
5.22 RS105, 50 kV/m
소재지
MIL-STD-461E : 1999 Requirements for the control of
electromagnetic interference
characteristics of subsystems and
equipment
5.4 CE101, conducted emissions, power
leads, 30 Hz to 10 kHz
5.5 CE102, conducted emissions, power
leads, 10 kHz to 10 MHz
5.6 CE106, conducted emissions, antenna
terminal, 10 kHz to 40 GHz
5.7 CS101, conducted susceptibility,
power leads, 30 Hz to 150 kHz
5.8 CS103, conducted susceptibility,
antenna port, intermodulation, 15 kHz to
10 GHz
5.9 CS104, conducted susceptibility,
antenna port, rejection of undesired
signals, 30 Hz to 20 GHz
5.10 CS105, conducted susceptibility, antenna port, cross modulation, 30 Hz to 20 GHz
5.12 CS114, conducted susceptibility,
bulk cable injection, 10 kHz to 200 MHz
5.13 CS115, conducted susceptibility,
bulk cable injection, impulse excitation
5.14 CS116, conducted susceptibility,
damped sinusoidal transients, cables and
power leads, 10 kHz to 100 MHz
5.15 RE101, radiated emissions, magnetic
field, 30 Hz to 100 kHz
5.16 RE102, radiated emissions, electric
field, 10 kHz to 18 GHz
5.18 RS101, radiated susceptibility,
magnetic field, 30 Hz to 100 kHz
5.19 RS103, radiated susceptibility,
electric field, 2 MHz to 40 GHz
5.20 RS105, radiated susceptibility, transient electromagnetic field
EUT 전원 용량
AC (0 ~ 440) V, 3Φ, 4 W
(0 ~ 50) A, 60 Hz
AC (0 ~ 115) V, 3Φ, 4 W
(0 ~ 50) A, 400 Hz
AC (0 ~ 220) V, 1Φ, 2 W
(0 ~ 100) A, 60 Hz
DC (0 ~ 40) V, 2 W
(0 ~ 128) A
5.4 CE101, 30 Hz to 10 kHz
5.5 CE102, 10 kHz to 10
MHz
5.6 CE106, 10 kHz to 40
GHz
5.7 CS101, 30 Hz to 150 kHz
5.8 CS103, 15 kHz to 10
GHz
5.9 CS104, 30 Hz to 20 GHz
5.10 CS105, 30 Hz to 20 GHz
5.12 CS114, 10 kHz to 200
MHz
5.13 CS115, 30 Hz, rated 5
A
5.14 CS116, 10 kHz, 100 kHz
, 1 MHz, 10 MHz, 30 MHz,
100 MHz
5.15 RE101, 30 Hz to 100
kHz
5.16 RE102, 10 kHz to 18
GHz
5.18 RS101, 30 Hz to 100
kHz
5.19 RS103, 2 MHz to 18
GHz, (0 ~ 60) V/m
5.20 RS105, 50 kV/m
소재지
MIL-STD-464D:2020 ELECTROMAGNETIC
ENVIRONMENTAL EFFECTS
REQUIREMENTS FOR
SYSTEM
5.1 Margins
5.2 Intra-system
electromagnetic
compatibility (EMC)
5.11 Electrical bonding
5.12 External grounds
Margins : safety critical & mission
Bonding : min. 1 mΩ
소재지