| ▶ 전자기적합성 |
| BS EN 55014-1:2017+A11:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 1: Emission (Exception) -. 3 phase equipment |
RE: 30 MHz∼ 1 GHz Disturbance Power: 30 MHz∼ 300 MHz CE: 0.15 MHz∼ 30 MHz Discontinuous disturbance: 0.15 MHz∼ 30 MHz |
소재지 |
| BS EN 55014-2:2015 |
Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Product family standard (Exception) -. 3 phase equipment |
ESD: ±2 kV ∼ ±30 kV RS: 3 V/m, (80 MHz ∼ 1 GHz) EFT/Burst: ±0.5 kV ∼ ±1 kV Surge: ±0.5 kV ∼ ±2 kV CS: 3 V, (0.15 MHz ∼ 230 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| BS EN 55032:2015+A11:2020 |
Electromagnetic compatibility of multimedia equipment-Emission requirements (Exception) -. 3 phase equipment -. Equipment input current ≥ 16 A per phase -. 3.17 DVB-S and ISDB of broadcast receiver equipment -. 3.1.9 broadcast satellite outdoor system |
CE : 9 kHz∼30 MHz RE : 30 MHz∼6 GHz |
소재지,부속시설-1 |
| BS EN 55035:2017+A11:2020 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements (Exception) -.3 phaseequipment -.Equipment in put current ≥16A per phase -.3.17 DVB-S and ISDB of broadcast receiver equipment -.3.1.9 broadcast satellite out door system |
ESD : ± 2 kV ∼ ± 8 kV RS : 3 V/m,(80 MHz ~ 1 GHz, 1.8 GHz, 2.6 GHz, 3.5 GHz, 5 GHz) EFT/Burst : ± 0.5 kV ~ ± 1 kV Surge : ± 0.5 kV ~ ± 4 kV CS : 3 V (0.15 MHz∼80 MHz) Magnetic : 1 A/m Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| BS EN 61000-4-11:2004+A1:2017 |
Electromagnetic compatibility(EMC)-Part 4-11: Testing and measurement techniques– Voltage dips, short interruptions and voltage variations immunity tests (Exception) -. 3 phase equipment |
max 16A |
소재지 |
| BS EN 61000-4-2:2009 |
Electromagnetic compatibility(EMC)-Part 4-2: Testing and measurement techniques-Electrostatic discharge immunity test (Exception) -. 3 phase equipment |
max 10 kV |
소재지 |
| BS EN 61000-4-3:2007+A2:2011 |
Electromagnetic compatibility(EMC)-Part 4-3: Testing and measurement techniques– Radiated, radio-frequency, electromagnetic field immunity test (Exception) -. 3 phase equipment |
max 10 V, 80 MHz∼1 GHz max 3 V, 1 GHz∼6 GHz |
소재지 |
| BS EN 61000-4-4:2013 |
Electromagnetic compatibility(EMC)-Part 4-4: Testing and measurement techniques– Electrical fast transient/burst immunity test (Exception) -. 3 phase equipment |
max 4 kV |
소재지 |
| BS EN 61000-4-5:2014+A1:2017 |
Electromagnetic compatibility(EMC)-Part 4-5: Testing and measurement techniques- Surge immunity test (Exception) -. 3 phase equipment |
max 4 kV |
소재지 |
| BS EN 61000-4-8:2010 |
Electromagnetic compatibility(EMC)-Part 4-8: Testing and measurement techniques- Power frequency magnetic field immunity test (Exception) -. 3 phase equipment |
Test level 30 A/m |
소재지 |
| CISPR 14-1:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission (Exception) -. 3 phase equipment |
RE: 30 MHz∼ 1 GHz Disturbance Power: 30 MHz∼ 300 MHz CE: 0.15 MHz∼ 30 MHz Discontinuous disturbance: 0.15 MHz∼ 30 MHz |
소재지 |
| CISPR 14-2:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard (Exception) -. 3 phase equipment |
ESD: ±2 kV ∼ ±30 kV RS: 3 V/m, (80 MHz ~ 1 GHz) EFT/Burst: ±0.5 kV ∼ ±1 kV Surge: ±0.5 kV ∼ ±2 kV CS: 3 V, (0.15 MHz ~ 230 MHz) Voltage dips/interruptions: ≤ 16 A, (0 % ~ 100 %) |
소재지 |
| CISPR 15:2018 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (Exception) -. 3 phase equipment |
RE: 9 kHz ∼ 1 GHz CE: 9 kHz ∼ 30 MHz Loop Ant max. ≤ 2.0 m |
소재지 |
| CISPR 32:2015+AMD1:2019 |
Amendment1 - Electromagnetic compatibility of multimedia equipment-Emission requirements (Exception) -. 3 phase equipment -. Equipment input current ≥ 16 A per phase -. 3.17 DVB-S and ISDB of broadcast receiver equipment -. 3.1.9 broadcast satellite outdoor system |
RE : 30 ㎒∼6 ㎓ CE : 0.15 ㎒∼30 ㎒ |
소재지,부속시설-1 |
| CISPR 35:2016 |
Electromagnetic compatibility of multimedia equipment – Immunity requirements (Exception) -.3 phase equipment -.Equipment in put current ≥16 A perphase -.3.17 DVB-S and ISDB of broadcast receiver equipment -.3.1.9 broadcast satellite outdoor system |
ESD : ± 2 kV ∼ ± 8 kV RS : 3 V/m,(80 MHz ~ 1 GHz, 1.8 GHz, 2.6 GHz, 3.5 GHz, 5 GHz) EFT : ± 0.5 kV ~ ± 1 kV Surge : ± 0.5 kV ~ ± 4 kV CS : 3 V, (0.15 MHz ∼ 80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| DS/EN 61000-4-6:2014/AC:2015 |
Electromagnetic compatibility(EMC)-Part 4-6: Testing and measurement techniques– Immunity to conducted disturbances, induced by radio-frequency fields |
max 10 V, 150 kHz∼230 MHz |
소재지 |
| ETSI EN 301 489-13:2002 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 13: Specific conditions for Citizens' Band (CB) radio and ancillary equipment (speech and non-speech) (Exception) -. 3 phase equipment |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| ETSI EN 301 489-17:2020 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised Standard for ElectroMagnetic Compatibility (Exception) -. 3 phase equipment |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| ETSI EN 301 489-1:2020 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility (Exception) -. 3 phase equipment -. Automotive Surge Test |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| ETSI EN 301 489-3:2019 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonised Standard for ElectroMagnetic Compatibility (Exception) -. 3 phase equipment |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| ETSI EN 301 489-50:2020 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50: Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment; Harmonised Standard for ElectroMagnetic Compatibility (Exception) -. 3 phase equipment |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| ETSI EN 301 489-52:2020 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication User Equipment (UE) radio and ancillary equipment; Harmonised Standard for ElectroMagnetic Compatibility (Exception) -. 3 phase equipment |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| ETSI EN 301 489-5:2019 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech) and Terrestrial Trunked Radio (TETRA); Harmonised Standard covering the essential requirements of article 3.1(b) of the Directive 2014/53/EU (Exception) -. 3 phase equipment |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| ETSI EN 301 489-9:2021 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 9: Specific conditions for wireless microphones, similar Radio Frequency (RF) audio link equipment, cordless audio and in-ear monitoring devices; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU (Exception) -. 3 phase equipment |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| IEC 61000-4-11:2020 |
Electromagnetic compatibility(EMC)-Part 4-11: Testing and measurement techniques– Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase (Exception) -. 3 phase equipment |
max 16A |
소재지 |
| IEC 61000-4-2:2008 |
Electromagnetic compatibility(EMC)-Part 4-2: Testing and measurement techniques-Electrostatic discharge immunity test (Exception) -. 3 phase equipment |
max 10 kV |
소재지 |
| IEC 61000-4-3:2020 |
Electromagnetic compatibility(EMC)-Part 4-3: Testing and measurement techniques– Radiated, radio-frequency, electromagnetic field immunity test (Exception) -. 3 phase equipment |
max 10 V, 80 MHz∼1 GHz max 3 V, 1 GHz∼6 GHz |
소재지 |
| IEC 61000-4-4:2012 |
Electromagnetic compatibility(EMC)-Part 4-4: Testing and measurement techniques– Electrical fast transient/burst immunity test (Exception) -. 3 phase equipment |
max 4 kV |
소재지 |
| IEC 61000-4-5:2014/AMD1:2017 |
Amendment 1 - Electromagnetic compatibility(EMC)-Part 4-5: Testing and measurement techniques - Surge immunity test (Exception) -. 3 phase equipment |
max 4 kV |
소재지 |
| IEC 61000-4-6:2013 |
Electromagnetic compatibility(EMC)-Part 4-6: Testing and measurement techniques– Immunity to conducted disturbances, induced by radio-frequency fields (Exception) -. 3 phase equipment |
max 10 V, 150 kHz∼230 MHz |
소재지 |
| IEC 61000-4-8:2009 |
Electromagnetic compatibility(EMC)-Part 4-8: Testing and measurement techniques- Power frequency magnetic field immunity test (Exception) -. 3 phase equipment |
Test level 30 A/m |
소재지 |
| IEC 61000-6-1:2016 |
Electromagnetic compatibility (EMC) – Part 6-1: Generic standards – Immunity standard for residential, commercial and light-industrial environments (Exception) -. 3 phase equipment |
ESD : ± 2 kV ∼ ± 8 kV RS : 3 V/m, (80 MHz to 1 GHz, 1.4 GHz to 6 GHz) EFT : ± 0.5 kV ~ ± 1 kV Surge : ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Magnetic : 3 A/m Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| IEC 61000-6-2:2016 |
Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity standard for industrial environments (Exception) -. 3 phase equipment |
ESD : ± 2 kV ∼ ± 30 kV RS : 10 V/m, (80 MHz to 1 GHz), 3 V/m, (1.4 GHz to 6 GHz) EFT/Burst: ± 1 kV ~ ± 2 kV Surge : ± 0.5 kV ~ ± 2 kV CS : 10 V (0.15 MHz∼80 MHz) Magnetic : 30 A/m Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| IEC 61000-6-3:2020 |
Electromagnetic compatibility (EMC)– Part 6-3: Generic standards – Emission standard for equipment in residential environments (Exception) -. 3 phase equipment |
RE: 30 MHz ∼ 6 GHz CE: 0.15 MHz ∼ 30 MHz Discontinuous disturbance: 0.15 MHz∼ 30 MHz |
소재지 |
| IEC 61000-6-4:2018 |
Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission standard for industrial environments (Exception) -. 3 phase equipment |
RE : 30 MHz ∼ 6 GHz CE : 0.15 MHz ∼ 30 MHz |
소재지 |
| KS C 9547:2020 |
일반 조명기기 - 전자파적합성(EMC) 내성 요구사항 (제외 항목) -. 3 상 기기 |
ESD: ±2 kV ∼ ±8 kV RS: 3 V/m, (80 MHz ~ 1 GHz) EFT/Burst: ±0.5 kV ∼ ±1 kV Surge: ±0.5 kV ∼ ±2 kV CS: 3 V, (0.15 MHz ~ 80 MHz) Voltage dips/interruptions: ≤ 16 A, (0 % ~ 100 %) |
소재지 |
| KS C 9610-4-11:2020 |
전자파적합성(EMC) - 제4-11부:시험 및 측정기술 - 전압 강하, 순간 정전, 전압 변동 내성 시험 (제외 항목) -. 3 상 기기 |
정격 입력 전류 (상당) ≥16 A |
소재지 |
| KS C 9610-4-2:2017 |
전자파적합성(EMC) - 제4-2부:시험 및 측정기술 - 정전기 방전 내성 시험 (제외 항목) -. 3 상 기기 |
ESD: ±2 kV ~ ±30 kV |
소재지 |
| KS C 9610-4-3:2017 |
전자파적합성(EMC) - 제4-3부:시험 및 측정기술 - 방사성 RF 전자기장 내성 시험 (제외 항목) -. 3 상 기기 |
RS: 10 V/m, (80 MHz ~ 1 GHz) 3 V/m, (1 GHz ~ 6 GHz) |
소재지 |
| KS C 9610-4-4:2020 |
전자파적합성(EMC) - 제4-4부:시험 및 측정기술 - 전기적 빠른 과도현상, 버스트 내성 시험 (제외 항목) -. 3 상 기기 |
EFT/Burst: ±0.5 kV ∼ ±4 kV |
소재지 |
| KS C 9610-4-5:2020 |
전자파적합성(EMC) - 제4-5부:시험 및 측정기술 - 서지 내성 시험 (제외 항목) -. 3 상 기기 |
Surge: ±0.5 kV ∼ ±4 kV |
소재지 |
| KS C 9610-4-6:2020 |
전자파적합성(EMC) - 제4-6부:시험 및 측정기술 - 전도성 RF 전자기장 내성 시험 (제외 항목) -. 3 상 기기 |
CS: 10 V, (0.15 MHz ~ 230 MHz) |
소재지 |
| KS C 9610-4-8:2017 |
전자파적합성(EMC) - 제 4-8부: 시험 및 측정기술 - 전원 주파수 자기장 내성 시험 (제외 항목) -. 3 상 기기 |
Magnetic: Max 30 A/m |
소재지 |
| KS C 9610-6-1:2019 |
전자파적합성(EMC) - 제6-1부:일반표준 - 주거, 상업 및 경공업 환경에서 사용하는 기기의 전자파 내성 표준 (제외 항목) -. 3 상 기기 |
ESD : ± 2 kV ∼ ± 8 kV RS : 3 V/m, (80 MHz ~ 1 GHz, 1.4 GHz ~ 6 GHz) EFT : ± 0.5 kV ~ ± 1 kV Surge : ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Magnetic : 3 A/m Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS C 9610-6-2:2019 |
전자파적합성(EMC) - 제6-2부:일반표준 - 산업 환경에서 사용하는 기기의 전자파 내성 표준 (제외 항목) -. 3 상 기기 |
ESD : ± 2 kV ∼ ± 8 kV RS : 10 V/m, (80 MHz ~ 1 GHz), 3 V/m, (1.4 GHz ~ 6 GHz) EFT : ± 1 kV ~ ± 2 kV Surge : ± 0.5 kV ~ ± 2 kV CS : 10 V, (0.15 MHz∼80 MHz) Magnetic : 30 A/m Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS C 9610-6-3:2023 |
전자파적합성(EMC) - 제6-3부:일반기준 - 주거용, 상업용 및 경공업 환경에서 사용하는 기기의 전자파 방해 표준 (제외 항목) -. 3 상 기기 |
RE : 30 MHz ∼ 6 GHz CE : 0.15 MHz ∼ 30 MHz Discontinuous disturbance: 0.15 MHz∼ 30 MHz |
소재지 |
| KS C 9610-6-4:2022 |
전자파적합성(EMC) - 제 6-4부:일반기준-산업 환경에서 사용하는 기기의 전자파 방해 표준 (제외 항목) -. 3 상 기기 |
RE : 30 MHz ∼ 6 GHz CE : 0.15 MHz ∼ 30 MHz |
소재지 |
| KS C 9814-1:2022 |
전자파적합성(EMC) - 가정용 전기기기,전동 공구 및 유사기기의 요구사항 제1부: 방출 (제외 항목) -. 3 상 기기 기기 입력 전류 ≥ 16 A |
RE: 30 MHz∼ 1 GHz Disturbance Power: 30 MHz∼ 300 MHz CE: 0.15 MHz∼ 30 MHz Discontinuous disturbance: 0.15 MHz∼ 30 MHz |
소재지 |
| KS C 9814-2:2022 |
전자파적합성(EMC) - 가정용 전기기기,전동 공구 및 유사기기의 요구사항 제2부: 내성 (제외 항목)
-. 3 상 기기 기기 입력 전류 ≥ 16 A |
ESD: ±2 kV ∼ ±30 kV RS: 3 V/m, (80 MHz ~ 1 GHz) EFT/Burst: ±0.5 kV ∼ ±1 kV Surge: ±0.5 kV ∼ ±2 kV CS: 3 V, (0.15 MHz ~ 230 MHz) Voltage dips/interruptions: ≤ 16 A, (0 % ~ 100 %) |
소재지 |
| KS C 9815:2023 |
조명 기기 및 유사 기기의 무선 방해 특성 측정 허용기준과 측정방법 (제외 항목) -. 3 상 기기 |
RE: 9 kHz ∼ 1 GHz CE: 9 kHz ∼ 30 MHz Loop Ant max. ≤ 2.0 m |
소재지 |
| KS C 9832:2023 |
멀티미디어 기기 전자파 방해 시험방법 <제외항목> -. 3 상 기기 -. 기기 입력 전류 ≥ 16 A -. 3.7 방송수신기기의 DVB-S 및 ISDB -. 3.24 위성방송 옥외 시스템 |
CE : 0.15 MHz ∼30 MHz RE : 30 MHz ∼ 6 GHz |
소재지 |
| KS C 9835:2019 |
멀티미디어 기기 전자파 내성 시험방법 <제외항목> -. 3 상 기기 -. 기기 입력 전류 ≥ 16 A -. 3.7 방송수신기기의 DVB-S 및 ISDB -. 3.24 위성방송 옥외 시스템 |
ESD : ± 2 kV ∼ ± 8 kV RS : 3 V/m,(80 MHz ~ 1 GHz, 1.8 GHz, 2.6 GHz, 3.5 GHz, 5 GHz) EFT : ± 0.5 kV ~ ± 1 kV Surge : ± 0.5 kV ~ ± 2 kV CS : 3 V (0.15 MHz∼80 MHz) Magnetic : 1 A/m Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS C 9992:2019 |
소방용품 전자파적합성 시험방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ∼ 1 GHz CE: 0.15 MHz ∼ 30 MHz ESD : ± 6 kV ∼ ± 8 kV RS : 10 V/m, (80 MHz ~ 1 GHz) EFT : ±1 kV ~ ±2 kV Surge : ±0.5 kV ~ ±2 kV CS : 10 V (0.15 MHz∼80 MHz) Magnetic: 30 A/m Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3124:2020 |
무선기기의 공통 전자파적합성 시험방법 <제외항목> -. 3 상 기기 -. 차량용서지시험 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3125:2020 |
특정 소출력 무선기기 전자파적합성 시험방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3126:2020 |
무선 데이터 통신 시스템용 특정 소출력 무선기기 전자파적합성 시험방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3127:2014 |
간이 무선국 전자파 적합성 시험 방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3129:2020 |
이동통신 단말기 및 보조기기의 전자파적합성 시험방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3130:2014 |
음성 및 음향 신호 전송용 특정 소출력 무선 기기 전자파 적합성 시험 방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3131:2014 |
생활 무전기 전자파 적합성 시험방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3132:2014 |
TRS 기기 전자파 적합성 시험방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3135:2020 |
이동통신 기지국, 중계기, 보조기기의 전자파적합성 시험방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |
| KS X 3137:2014 |
무선 호출용 기기의 전자파 적합성 시험 방법 (제외 항목) -. 3 상 기기 |
RE: 30 MHz ~ 6 GHz CE: 0.15 MHz ~ 30 MHz ESD : ± 2 kV ∼ ± 8 kV RS: 3 V/m, (80 MHz ~ 6 GHz) EFT/Burst: ± 0.5 kV ~ ± 1 kV Surge: ± 0.5 kV ~ ± 2 kV CS : 3 V, (0.15 MHz∼80 MHz) Voltage dips/interruptions: ≤16 A, (0 % ~ 100 %) |
소재지 |