| ▶ 유/무선 통신기기 |
| 3GPP TS 34.121-1:2019 |
Technical Specification Group Radio Access Network; User Equipment (UE) conformance specification; Radio transmission and reception (FDD); Part 1: Conformance specification |
(800 ~ 2 200) MHz |
소재지 |
| 3GPP TS 36.521-1:2025 |
3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Evolved Universal Terrestrial Radio Access (E-UTRA); User Equipment (UE) conformance specification Radio transmission and reception Part 1: Conformance Testing |
(0.9 ~ 19 000) MHz |
소재지 |
| 3GPP TS 36.521-3:2025 |
3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Evolved Universal Terrestrial Radio Access (E-UTRA); User Equipment (UE) conformance specification; Radio transmission and reception; Part 3: Radio Resource Management (RRM) conformance testing |
(0.9 ~ 19 000) MHz |
소재지 |
| 3GPP TS 38.521-1:2025 |
3rd Generation Partnership Project; Technical Specification Group Radio Access Network; NR; User Equipment (UE) conformance specification; Radio transmission and reception; Part 1: Range 1 Standalone; |
FR1: (410 ~ 7 125) MHz |
소재지 |
| 3GPP TS 38.521-2:2025 |
3rd Generation Partnership project; Technical Specification Group Radio Access Network; NR; User Equipment (UE) conformance specification; Radio transmission and reception; Part 2: Range 2 Standalone |
FR2: (24 250 ~ 29 500) MHz |
소재지 |
| 3GPP TS 38.521-3:2025 |
3rd Generation Partnership Project; Technical Specification Group Radio Access Network; NR; User Equipment (UE) conformance specification; Radio transmission and reception; Part 3: Range 1 and Range 2 Interworking operation with other radios
|
FR1: (410 ~ 7 125) MHz, FR2: (24 250 ~ 29 500) MHz |
소재지 |
| 3GPP TS 38.521-4:2025 |
3rd Generation Partnership Project; Technical Specification Group Radio Access Network; NR; User Equipment (UE) conformance specification; Radio transmission and reception; Part 4: Performance requirements
|
FR1: (410 ~ 7 125) MHz, FR2: (24 250 ~ 29 500) MHz |
소재지 |
| 3GPP TS 38.533:2025 |
3rd Generation Partnership Project; Technical Specification Group Radio Access Network; NR; User Equipment (UE) conformance specification; Radio Resource Management (RRM)
|
FR1: (410 ~ 7 125) MHz, FR2: (24 250 ~ 29 500) MHz |
소재지 |
| 3GPP TS 51.010-1:2024 |
3rd Generation Partnership Project; Technical Specification Group Radio Access Network; Digital cellular telecommunications system (Phase 2+); Mobile Station (MS) conformance specification; Part 1: Conformance specification |
(0 ~ 12.75) GHz |
소재지 |
| ETSI EN 301 511:2015 |
Global System for Mobile communications (GSM); Harmonized EN for mobile stations in the GSM 900 and GSM 1800 bands covering essential requirements under article 3.2 of the R&TTE directive |
(0 ~ 12.75) GHz |
소재지 |
| ETSI EN 301 511:2017 |
Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
(0 ~ 12.75) GHz |
소재지 |
| ETSI EN 301 908-13:2013 |
IMT cellular networks; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE) |
(0.9 ~ 19 000) MHz |
소재지 |
| ETSI EN 301 908-13:2015 |
IMT cellular networks; Harmonised EN covering the essential requirements of article 3.2 of the R&TTE Directive; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE) |
(0 ~ 20) GHz |
소재지 |
| ETSI EN 301 908-13:2017 |
IMT cellular networks; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE) |
(0 ~ 20) GHz |
소재지 |
| ETSI EN 301 908-13:2019 |
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE) |
(0 ~ 20) GHz |
소재지 |
| ETSI EN 301 908-13:2022 |
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE) |
(0 ~ 20) GHz |
소재지 |
| ETSI EN 301 908-2: 2015 |
IMT cellular networks; Harmonised EN covering the essential requirements of article 3.2 of the R&TTE Directive; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE) |
(0 ~ 20) GHz |
소재지 |
| ETSI EN 301 908-2:2013 |
IMT cellular networks; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment(UE)
(Exception) 4.2.2.2 Limits: Operating Band XV, XVI 4.2.4.2 Limits: Operating Band XV, XVI 4.2.7.2 Limits: Operating Band XV, XVI 4.2.10.2 Limits: Operating Band XV, XVI |
(800 ~ 2 200) MHz |
소재지 |
| ETSI EN 301 908-2:2017 |
IMT cellular networks; Harmonised Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE) |
(0 ~ 20) GHz |
소재지 |
| ETSI EN 301 908-2:2020 |
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE) |
(0 ~ 20) GHz |
소재지 |
| ▶ 전자기적합성 |
| EPRI TR 102323 Revision 2:2000 |
Guidelines for Electromagnetic Interference Testing of Power Plant Equipment
5-8 Low-Frequency Conducted Susceptibility 5-10 High-Frequency Conducted Susceptibility 5-12 Low-Frequency Radiated Susceptibility 5-14 High-Frequency Radiated Susceptibility 5-18 Low-Frequency Conducted Emissions 5-20 High-Frequency Conducted Emissions 5-22 Low-Frequency Radiated Emissions 5-24 High-Frequency Radiated Emissions |
5-8: 30 Hz to 50 kHz 5-10: 10 kHz to 200 MHz 5-12: 30 Hz to 100 kHz 5-14: 10 kHz to 10 GHz 5-18: 30 Hz to 10 kHz 5-20: 10 kHz to 10 MHz 5-22: 30 Hz to 100 kHz 5-24: 10 kHz to 10 GHz |
소재지 |
| EPRI TR 102323 Revision 3:2004 |
Guidelines for Electromagnetic Interference Testing of Power Plant Equipment
5-6 Low-Frequency Conducted Susceptibility 5-8 High-Frequency Conducted Susceptibility 5-10 Low-Frequency Radiated Magnetic Field Susceptibility 5-12 High-Frequency Radiated electric Field Susceptibility 5-19 Low-Frequency Conducted Emissions 5-21 High-Frequency Conducted Emissions 5-23 Low-Frequency Radiated Magnetic Field Emissions 5-24 High-Frequency Radiated Electric Field Emissions |
5-6: 30 Hz to 50 kHz 5-8: 10 kHz to 200 MHz 5-10: 30 Hz to 100 kHz 5-12: 10 kHz to 10 GHz 5-19: 30 Hz to 10 kHz 5-21: 10 kHz to 10 MHz 5-23: 30 Hz to 100 kHz 5-24: 10 kHz to 10 GHz |
소재지 |
| MIL-STD-461D:1993 |
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE EMISSIONS AND SUSCEPTIBILITY
5.3.1 CE101, Conducted emissions, power leads, 30 Hz to 10 kHz 5.3.2 CE102, Conducted emissions, power leads, 10 kHz to 10 MHz 5.3.4 CS101, Conducted susceptibility, power leads, 30 Hz to 50 kHz 5.3.9 CS114, Conducted susceptibility, bulk cable injection, 10 kHz to 400 MHz 5.3.10 CS115, Conducted susceptibility, bulk cable injection, impulse excitation 5.3.11 CS116, Conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.3.12 RE101, Radiated emissions, magnetic field,30 Hz to 100 kHz 5.3.13 RE102, Radiated emissions, electric field, 10 kHz to 18 GHz 5.3.15 RS101, Radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.3.16 RS103, Radiated susceptibility, electric field, 10 kHz to 40 GHz (Exception: below 100 MHz, 200 V/m) |
30 Hz to 10 kHz 10 kHz to 10 MHz 30 Hz to 50 kHz 10 kHz to 400 MHz 5 A 10 A, 10 kHz to 100 MHz 30 Hz to 100 kHz 10 kHz to 18 GHz 30 Hz to 100 kHz 10 kHz to 18 GHz |
소재지 |
| MIL-STD-461E:1999 |
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
5.4 CE101, conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, conducted emissions, power leads, 10 kHz to 10 MHz 5.7 CS101, conducted susceptibility, power leads, 30 Hz to 150 kHz 5.12 CS114, conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz 5.13 CS115, conducted susceptibility, bulk cable injection, impulse excitation 5.14 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.15 RE101, Radiated emissions, magnetic field, 30 Hz to 100 kHz 5.16 RE102, radiated emissions, electric field, 10 kHz to 18 GHz 5.18 RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.19 RS103, radiated susceptibility, electric field, 2 MHz to 40 GHz (Exception: below 100 MHz, 200 V/m) |
30 Hz to 10 kHz 10 kHz to 10 MHz 30 Hz to 150 kHz 10 kHz to 200 MHz 5 A 10 A, 10 kHz to 100 MHz 30 Hz to 100 kHz 10 kHz to 18 GHz 30 Hz to 100 kHz 10 kHz to 18 GHz |
소재지 |
| MIL-STD-461F:2007 |
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
5.4 CE101, conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, conducted emissions, power leads, 10 kHz to 10 MHz 5.7 CS101, conducted susceptibility, power leads, 30 Hz to 150kHz 5.11 CS106, conducted susceptibility, transients, power leads 5.13 CS114, conducted susceptibility, bulk cable injection,10 kHz to 200 MHz 5.14 CS115, Conducted susceptibility, bulk cable injection, impulse excitation 5.15 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.16 RE101, radiated emissions, magnetic field, 30 Hz to 100 kHz 5.17 RE102, radiated emissions, electric field, 10 kHz to 18 GHz 5.19 RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.20 RS103, radiated susceptibility, electric field, 2 MHz to 40 GHz (Exception: below 100 MHz, 200 V/m) |
30 Hz to 10 kHz 10 kHz to 10 MHz 30 Hz to 150 kHz 400 V 10 kHz to 200 MHz 5 A 10 A, 10 kHz to 100 MHz 30 Hz to 100 kHz 10 kHz to 18 GHz 30 Hz to 100 kHz 10 kHz to 18 GHz |
소재지 |
| MIL-STD-461G:2015 |
REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEM SAND EQUIPMENT 5.4 CE101, conducted emissions, audio frequency currents, power leads 5.5 CE102, conducted emissions, radio frequency potential, power leads 5.7 CS101, conducted susceptibility, power leads 5.12 CS114, conducted susceptibility, bulk cable injection 5.13 CS115, conducted susceptibility, bulk cable injection, impulse excitation 5.14 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads 5.16 CS118, personnel borne electrostatic discharge 5.17 RE101, radiated emissions, magnetic field 5.18 RE102, radiated emissions, electric field 5.20 RS101, radiated susceptibility, magnetic field 5.21 RS103, radiated susceptibility, electric field (Exception: below 100 MHz, 200 V/m) |
30 Hz to 10 kHz 10 kHz to 10 MHz 30 Hz to 150 kHz 10 kHz to 200 MHz 5 A 10 A,10 kHz to 100 MHz ±15 kV(Air), ±8 kV(Contact) 30 Hz to 100 kHz 10 kHz to 18 GHz 30 Hz to 100 kHz 10 kHz to 18 GHz |
소재지 |
| MIL-STD-462D:1993 |
MEASUREMENT OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS
5. CE101, CONDUCTED EMISSIONS, POWER LEADS, 30 Hz TO 10 kHz 5. CE102, CONDUCTED EMISSIONS, POWER LEADS, 10 kHz TO 10 MHz 5. CS101, CONDUCTED SUSCEPTIBILITY, POWER LEADS, 30 Hz TO 50 kHz 5. CS114, CONDUCTED SUSCEPTIBILITY, BULK CABLE INJECTION, 10 kHz TO 400 MHz 5. CS115, CONDUCTED SUSCEPTIBILITY, BULK CABLE INJECTION, IMPULSE EXCITATION 5. CS116, CONDUCTED SUSCEPTIBILITY, DAMPED SINUSOIDAL TRANSIENTS, CABLES AND POWER LEADS, 10 kHz TO 100 MHz 5. RE101, RADIATED EMISSIONS, MAGNETIC FIELD, 30 Hz TO 100 kHz 5. RE102, RADIATED EMISSIONS, ELECTRIC FIELD, 10 kHz TO 18 GHz 5. RS101, RADIATED SUSCEPTIBILITY, MAGNETIC FIELD, 30 Hz TO 100 kHz 5. RS103, RADIATED SUSCEPTIBILITY, ELECTRIC FIELD, 10 kHz TO 40 GHz (Exception: below 100MHz, 200 V/m) |
30 Hz to 10 kHz 10 kHz to 10MHz 30Hz to 50 kHz 10kHz to 400 MHz 5A 10A, 10 kHz to 100 MHz 30 Hz to 100 kHz 10 kHz to 18 GHz 30 Hz to 100 kHz 10 kHz to 18 GHz |
소재지 |
| REGULATORY GUIDE 1.180 Revision 1:2003 |
GUIDANCE FOR EVALUATING ELECTROMAGNETIC AND RADIO-FREQUENCY INTERFERENCE IN SAFETY-RELATED INSTRUMENTATION AND CONTROL SYSTEMS
3.1 CE101-Conducted Emissions, Low Frequency 3.2 CE102-Conducted Emissions, High Frequency 3.3 RE101-Radiated Emissions, Magnetic Field 3.4 RE102-Radiated Emissions, Electric Field 4.1.1 CS101-Conducted Susceptibility, Low Frequency 4.1.2 CS114-Conducted Susceptibility, High Frequency 4.2 EMI/RFI Conducted Susceptibility Testing- Signal Leads 4.3.1 RS101-Radiated susceptibility, Magnetic Fields 4.3.2 RS103-Radiated susceptibility, Electric Fields |
3.1 CE101: 30 Hz to 10 kHz 3.2 CE102: 10 kHz to 2 MHz 3.3 RE101: 30 Hz to 100 kHz 3.4 RE102: 2 MHz to 10 GHz 4.1.1 CS101: 30 Hz to 150 kHz 4.1.2 CS114: 10 kHz to 30 MHz 4.2 EMI/RFI-Signal Leads 10 kHz to 30 MHz for CS114, 2 A for CS115, 5 A for CS116 4.3.1 RS101: 30 Hz to 100 kHz 4.3.2 RS103: 30 MHz to 10 GHz |
소재지 |
| REGULATORY GUIDE 1.180:2000 |
GUIDANCE FOR EVALUATING ELECTROMAGNETIC AND RADIO-FREQUENCY INTERFERENCE IN SAFETY-RELATED INSTRUMENTATION AND CONTROL SYSTEMS
4.1 CE101-Conducted emissions, Low Frequency 4.2 CE102-Conducted emissions, High Frequency 4.3 CS101-Conducted susceptibility, Low Frequency 4.4 CS114-Conducted susceptibility, High Frequency 4.5 RE101-Radiated emissions, Magnetic field 4.6 RE102-Radiated emissions, Electric field 4.7 RS101-Radiated susceptibility, Magnetic Fields 4.8 RS103-Radiated susceptibility, Electric Fields |
4.1 CE101: 30 Hz to 10 kHz 4.2 CE102: 10 kHz to 10 MHz 4.3 CS101: 30 Hz to 50 kHz 4.4 CS114: 10 kHz to 400 MHz 4.5 RE101: 30 Hz to 100 kHz 4.6 RE102: 10 kHz to 1 GHz 4.7 RS101: 30 Hz to 100 kHz 4.8 RS103: 10 kHz to 1GHz |
소재지 |