| ▶ 전자기적합성 |
| IEC 60945 Ed. 4.0b:2002 |
Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results |
RE: 150 kHz ∼ 6 GHz CE: 10 kHz ∼ 30 MHz ESD: ±8 kV RS: 80 MHz ∼ 2 GHz 10 V/m EFT: ±2 kV Surge: ±2 kV CS: 150 kHz ∼ 80 MHz 10 V DIP: (0~100) % |
소재지 |
| KS C 9811:2019 |
산업, 과학, 의료용(ISM) 기기— 무선주파수방해특성— 허용기준및측정방법 |
CE : 10 kHz ∼ 30 MHz RE : 10 kHz ∼ 18 GHz |
소재지 |
| MIL-STD-461E:1999 |
DEPARTMENT OF DEFENSE INTERFACE STANDARD REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT 5.4 CE101, Conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, Conducted emissions, power leads, 10 kHz to 10 MHz 5.7 CS101, Conducted susceptibility, power leads, 30 Hz to 150 kHz 5.12 CS114, Conducted susceptibility, bulk cable injection, 4 kHz to 200 MHz 5.13 CS115, Conducted susceptibility, bulk cable injection, impulse excitation 5.14 CS116, Conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.15 CS117, conducted susceptibility, lightning induced transients, cables and power leads. 5.16 CS118, personnel borne electrostatic discharge. 5.17 RE101, Radiated emissions, magnetic field, 30 Hz to 100 kHz 5.18 RE102, Radiated emissions, electric field, 10 kHz to 18 GHz 5.20 RS101, Radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.21 RS103, Radiated susceptibility, electric field, 2 MHz to 40 GHz [exception] 2 MHz to 30 MHz, 200 V/m |
CE101: 30 Hz ∼10 kHz CE102: 10 kHz ∼10 MHz CS101: 30 Hz ∼150 kHz CS114: 10 kHz ∼200 MHz CS115: Impulse 5 A CS116: 10 kHz ∼100 MHz RE101: 30 Hz ∼100 kHz RE102: 10 kHz ∼18 GHz RS101: 30 Hz ∼100 kHz RS103: 2 MHz ∼40 GHz (Max 60V/m) |
소재지 |
| MIL-STD-461F:2007 |
DEPARTMENT OF DEFENSE INTERFACE STANDARD REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT 5.4 CE101, Conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, Conducted emissions, power leads, 10 kHz to 10 MHz 5.7 CS101, Conducted susceptibility, power leads, 30 Hz to 150 kHz 5.13 CS114, Conducted susceptibility, bulk cable injection 4 kHz to 200 MHz 5.14 CS115, Conducted susceptibility, bulk cable injection, impulse excitation 5.15 CS116, Conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.16 RE101, Radiated emissions, magnetic field, 30 Hz to 100 kHz 5.17 RE102, Radiated emissions, electric field, 10 kHz to 18 GHz 5.19 RS101, Radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.20 RS103, Radiated susceptibility, electric field, 2 MHz to 40 GHz [exception] 2 MHz to 30 MHz, 200 V/m |
CE101: 30 Hz ∼ 10 kHz CE102: 10 kHz ∼ 10 MHz CS101: 30 Hz ∼ 150 kHz CS114: 4 kHz ∼ 200 MHz CS115: Impulse 5 A CS116: 10 kHz ∼ 100 MHz RE101: 30 Hz ∼ 100 kHz RE102: 10 kHz ∼ 18 GHz RS101: 30 Hz ∼ 100 kHz RS103: 2 MHz ∼ 40 GHz (Max 60V/m) |
소재지 |
| MIL-STD-461G:2015 |
DEPARTMENT OF DEFENSE INTERFACE STANDARD REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT 5.4 CE101, Conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, Conducted emissions, power leads, 10 kHz to 10 MHz 5.7 CS101, Conducted susceptibility, power leads, 30 Hz to 150 kHz 5.12 CS114, Conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz 5.13 CS115, Conducted susceptibility, bulk cable injection, impulse excitation 5.14 CS116, Conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.15 RE101, Radiated emissions, magnetic field, 30 Hz to 100 kHz 5.16 RE102, Radiated emissions, electric field, 10 kHz to 18 GHz 5.18 RS101, Radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.19 RS103, Radiated susceptibility, electric field, 2 MHz to 40 GHz [exception] 2 MHz to 30 MHz, 200 V/m |
CE101: 30 Hz ∼10 kHz CE102: 10 kHz ∼10 MHz CS101: 30 Hz ∼150 kHz CS114: 4 kHz ∼200 MHz CS115: Impulse 5 A CS116: 10 kHz ∼100 MHz CS118: (±2 ~ ±15)kV RE101: 30 Hz ∼100 kHz RE102: 10 kHz ∼18 GHz RS101: 3 0 Hz ∼100 kHz RS103: 2 MHz ∼40 GHz (Max 60V/m) |
소재지 |
| ▶ 소프트웨어 |
| IEC 61508-3:2010 |
Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements Table B.1 |
- |
소재지 |
| ISO 26262-6:2018 |
Road vehicles — Functional safety — Part 6: Product development at the software level Table 6 |
- |
소재지 |
| ISO/IEC 25023:2016 |
Systems and software engineering - Systems and software Quality Requirements and Evaluation (SQuaRE) - Measurement of system and software product quality 8.2.1 functional completeness measures 8.2.2 functional correctness measures |
- |
소재지 |
| KS C IEC 61508-3:2010 |
전기/전자/프로그램 가능한 전자장치 안전 관련 시스템의 기능 안전성 —제3부: 소프트웨어 요구사항 Table B.1 |
- |
소재지 |
| KS R ISO 26262-6:2018 |
도로 차량 — 기능 안전 — 제6부: 소프트웨어 수준에서의 제품 개발 Table 6 |
- |
소재지 |
| KS X ISO/IEC 25023:2016 |
시스템 및 소프트웨어 공학 — 시스템 및 소프트웨어 품질 요구사항 및 평가(SQuaRE) — 시스템 및 소프트웨어 제품 품질 측정 8.2.1 기능 완전성 측정 8.2.2 기능 정확성 측정 |
- |
소재지 |