| ▶ 전자기적합성 |
| ISO 7637-3:2016 |
Road vehicles — Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines |
12 V System 24 V System |
소재지 |
| EN 61000-3-3:2013+A2:2021 |
Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection [Exception] 3 phase equipment |
≤16 A per phase |
소재지 |
| EN 61000-3-2:2014 |
Limits for harmonic current emissions (equipment input current ≤16 A per phase) [Exception] Annex A for three phase equipment |
≤16 A per phase ODD: 3 ~ 39 order EVEN: 2 ~ 40 order |
소재지 |
| EN 61000-3-3:2013 |
Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection [Exception] 3 phase equipment |
≤16 A per phase |
소재지 |
| EN 55011:2016/A11:2020 |
Industrial, scientific and medical equipment-Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] - Rated power of ≥ 20 KVA - 30 m measuring distance of Electromagnetic radiation disturbance |
1) Disturbance voltage -Rated power of ≤ 20 KVA
2) Conducted disturbance -Rated power of ≤ 20 KVA
3) Electromagnetic radiation disturbance -Rated power of ≤ 20 KVA |
소재지 |
| ISO 7637-2:2011 |
Road vehicles — Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only |
12 V System 24 V System |
소재지 |
| ISO 11452-9:2021 |
Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Potable transmitters |
Frequency : 142 MHz ~ 6.0 GHz |
소재지 |
| ISO 11452-8:2015 |
Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields |
Frequency : DC ~ 150 kHz |
소재지 |
| ISO 11452-4:2020 |
Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy —Part 4: Harness excitation methods [Exception] 6.2. TWC Test method |
Frequency : 100 kHz ~ 400 MHz |
소재지 |
| ISO 11452-2:2019 |
Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure |
Frequency : 80 MHz ~ 6 GHz |
소재지 |
| CISPR 25:2021 |
Vehicles, Boats and Internal Combustion Engines - Radio Disturbance Characteristics Limits and Methods of Measurement for the Protection of On-Board Receivers [Exception] 5. Measurement of emissions received by an antenna on the same vehicle 6.6 Radiated emissions from components/modules - Stripline method |
1) Conducted Electromagnetic Fields (Voltage) -Frequency : 100 kHz ~ 150 MHz
2) Conducted Electromagnetic Fields (Current) -Frequency : 10 kHz ~ 400 MHz
2) Radiated Electromagnetic Fields -Frequency : 9 kHz ~ 6.0 GHz |
소재지 |
| KS C 9832:2019 |
멀티미디어기기 전자파 장해방지 시험방법 [제외항목] 3상 전원제품 |
방사 : 30 MHz ~ 6 GHz 전도 : 150 kHz ~ 30 MHz |
소재지 |
| KS C 9835:2019 |
멀티미디어기기 전자파 내성 시험방법 |
1) 정전기 방전 (ESD) -접촉 ±(2,4,6,8,특수) kV -공기 ±(2,4,8,15,특수) kV 특수 레벨은 최대 ±30 kV 2) 방사 전자기장 -주파수 80 MHz ~ 1 GHz -레벨 (1 ~ 10) V/m 3) 고속 과도 전압(BURST) -전원 포트 : ±(0.5,1,2,4,특수) kV -입출력 포트 : ±(0.25,0.5,1,2,특수) kV 특수 레벨은 최대 ±4.5 kV 반복 주기 5 kHz 또는 100 kHz 4) 서지: 전원 및 통신 포트 대상 1.2/50-8/20 us : ±(0.5,1,2,4,특수) kV 특수 레벨은 최대 ±15 kV 5) 전도성 장애 내성 -주파수 0.15 MHz ~ 80 MHz -레벨 (1 ~ 10) V 6) 자기장 시험 레벨 (1,3,10,30,100) A/m 7) 전압 강하 및 정전 0 % ~ 100 % 감소 |
소재지 |
| IEC 61000-3-2:2018+A2:2024 |
Limits for harmonic current emissions (equipment input current ≤16 A per phase) [Exception] Annex A for three phase equipment |
≤16 A per phase ODD: 3 ~ 39 order EVEN: 2 ~ 40 order |
소재지 |
| CISPR 35:2016 |
Electromagnetic compatibility of multimedia equipment – Immunity requirements [Exception] three phase equipment |
ESD: ±8 kV RS: 80 MHz ~ 6 GHz EFT: ±1 kV SURGE: ±4 kV CS: 150 kHz ~ 80 MHz M/F: 1 A/m V-DIP: 30 %, 100 % |
소재지 |
| FCC Part 15:2016 |
Radio Frequencies Devices [Exception] Section 15.118 Cable ready consumer electronics equipment. Section 15.249 Operation within the bands 902–928 MHz, 2400-2483.5 MHz,5725-5875 MHz, and 24.0-24.24.25GHz. Section 15.252 Operation of wideband vehicular radar systems within the bands 16.2-17.7 GHz and 23.12-29 GHz. Section 15.253 Operation within the bands 46.7-46.9 ㎓ and 76.0-77.0 ㎓. Section 15.255 Operation within the bands 57-64 ㎓. Section 15.257 Operation within the bands 92-95 ㎓. Subpart D-Unlicensed Personal Communication Service Devices Subpart E-Unlicensed National Information Infrastructure Devices Subpart F-Ultra-Wideband Operation Subpart G-Access Broadband Over Power Line (Access BPL) |
9 kHz ~ 40 GHz |
소재지 |
| IEC 61000-3-3:2013+A2:2021 |
Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection [Exception] 3 phase equipment |
≤16 A per phase |
소재지 |
| CISPR 11:2015+A1:2016+A2:2019 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] - Rated power of ≥ 20 KVA - 30 m measuring distance of Electromagnetic radiation disturbance |
1) Disturbance voltage -Rated power of ≤ 20 KVA
2) Conducted disturbance -Rated power of ≤ 20 KVA
3) Electromagnetic radiation disturbance -Rated power of ≤ 20 KVA |
소재지 |
| EN IEC 61000-3-2:2019 |
Limits for harmonic current emissions(equipment input current ≤ 16 A per phase) [Exception] Annex A for three phase equipment |
≤ 16 A per phase ODD: 3 - 39 order EVEN: 2 - 40 order |
소재지 |
| CISPR 32:2015+A1:2019 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
0.15 MHz ~ 18 GHz |
소재지 |
| EN IEC 61000-6-1:2019 |
Generic standards – Immunity for residential, commercial and light-industrial environments |
1) Electrostatic Discharge(ESD) -Contact ±4 kV -Air ±8 kV 2) Radiated Electromagnetic Fields -Frequency : 80 MHz ~ 1.0 GHz -Level : 3 V/m –80 % AM(1 kHz) -Frequency : 1.4 GHz ~ 6.0 GHz -Level : 3 V/m –80 % AM(1 kHz)
3) Electrical Fast Transients(BURST) 0.5 kV, 5/50 Tr/Th ns, Repetition freqency : 5 kHz or 100 kHz
4) Radio-frequency common mode -Frequency : 0.15 MHz ~ 80 MHz -Level : 3 V, -80 % AM(1 kHz)
5) Power-frequency magnetic field (50, 60) Hz, 3 A/m |
소재지 |
| EN IEC 61000-6-2:2019 |
Generic standards – Immunity standard for industrial environments |
1) Electrostatic Discharge(ESD) -Contact ±4 kV -Air ±8 kV
2) Radiated Electromagnetic Fields -Frequency : 80 MHz ~ 1.0 GHz -Level : 10 V/m -80 % AM(1 kHz) -Frequency : 1.4 GHz ~ 6.0 GHz -Level : 3 V/m -80 % AM(1 kHz)
3) Electrical Fast Transients(BURST) 0.5 kV, 5/50 Tr/Th ns, Repetition freqency : 5 kHz or 100 kHz
4) Radio-frequency common mode -Frequency : 0.15 MHz ~ 80 MHz -Level : 10 V, -80 % AM(1 kHz)
5) Power-frequency magnetic field (50, 60) Hz, 30 A/m |
소재지 |
| EN IEC 61000-6-4:2019 |
Generic standards – Emission standard for industrial environments |
1) Emission test-Enclosure port -30 MHz to 6 GHz
2) Emission test-Low voltage AC mains port -0.15 MHz to 30 MHz |
소재지 |
| EN 55032:2015+A11:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE : 30 MHz ~ 6 GHz CE : 150 kHz ~ 30 MHz |
소재지 |
| EN 55035:2017+A11:2020 |
Electromagnetic compatibility of multimedia equipment – Immunity requirements [Exception] three phase equipment |
1) Electrostatic Discharge(ESD) -Contact ±4 kV -Air ±8 kV
2) Radiated Electromagnetic Fields -Frequency : 80 MHz ~ 1.0 GHz -Level : 3 V/m –80 % AM(1 kHz) -Frequency : 1.8 GHz, 2.6 GHz, 3.5 GHz, 5 GHz -Level : 3 V/m –80 % AM(1 kHz)
3) Electrical Fast Transients(BURST) 1 kV ,0.5 kV, 5/50 Tr/Th ns, Repetition freqency : 5 kHz
4) Surges ±0.5 kV, ±1 kV, ±2 kV
5) Radio-frequency common mode -Frequency : 0.15 MHz ~ 10 MHz -Level : 3 V, -80 % AM(1 kHz) -Frequency : 10 MHz ~ 30 MHz -Level : 3 to 1 V, -80 % AM(1 kHz) -Frequency : 30 MHz ~ 80 MHz -Level : 1 V, -80 % AM(1 kHz)
6) Power-frequency magnetic field (50, 60) Hz, 1 A/m
7) Voltage dips -Residual voltage(<5 %, 70 %) |
소재지 |
| EN 55011:2016 |
Industrial, scientific and medical equipment-Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] - Rated power of ≥ 20 KVA - 30 m measuring distance of Electromagnetic radiation disturbance |
1) Disturbance voltage -Rated power of ≤ 20 KVA
2) Conducted disturbance -Rated power of ≤ 20 KVA
3) Electromagnetic radiation disturbance -Rated power of ≤ 20 KVA |
소재지 |
| EN 61000-6-3:2007+A1:2011/AC:2012 |
Generic standards – Emission for residential, commercial and light - industrial environments [Exception] Emission test-Low voltage AC mains port 0 kHz to 2 kHz |
1) Emission test-Enclosure port -30 MHz to 6 GHz
2)Emission test-Low voltage AC mains port -0.15 MHz to 30 MHz |
소재지 |
| ISO 10605:2023 |
Road vehicles — Test methods for electrical disturbances from electrostatic discharge |
1) Electrostatic Discharge(ESD) -Contact: ± 25 kV -Air: ± 25 kV |
소재지 |
| EN IEC 61000-3-2:2019+A2:2024 |
Limits for harmonic current emissions (equipment input current ≤16 A per phase) [Exception] Annex A for three phase equipment |
≤16 A per phase ODD: 3 ~ 39 order EVEN: 2 ~ 40 order |
소재지 |
| ▶ 유/무선 통신기기 |
| EN 50566:2017+A1:2023 |
Product Standard to demonstrate the compliance of wireless communication devices with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 30 MHz to 6 GHz:hand-held and body mounted devices in close proximity to the human body |
2.4 GHz ~ 6 GHz |
소재지 |
| EN 50360:2017+A1:2023 |
Product standard to demonstrate the compliance of wireless communication devices, with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 300 MHz to 6 GHz:devices used next to the ear |
2.4 GHz ~ 6 GHz |
소재지 |
| EN 62209-2:2010+A1:2019 |
Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices – Human models, instrumentation, and procedures Part 2:Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body(frequency range of 30 MHz to 6 GHz) |
2.4 GHz ~ 6 GHz |
소재지 |
| EN 50663:2017 |
Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz) |
2.4 GHz ~ 6 GHz |
소재지 |