| ▶ 산업용 전기기기 |
| EN 60204-1:2018 |
Safety of machinery-Electrical equipment of machines Part 1 : General requirements 18.2.2 Test 1 - Verification of the continuity of the protective bonding circuit 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit : Max. 10 A Insulation resistance : DC 500 V, (1 ~ 5 000) ㏁ Volatage test : AC (1 ~ 5) kV Protection against residual voltage : Max. 500 V |
소재지 |
| IEC 60204-1:2016+AMD1:2021 |
Safety of machinery-Electrical equipment of machines Part 1 : General requirements 18.2.2 Test 1 - Verification of the continuity of the protective bonding circuit 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit : Max. 10 A Insulation resistance : DC 500 V, (1 ~ 5 000) ㏁ Volatage test : AC (1 ~ 5) kV Protection against residual voltage : Max. 500 V |
소재지 |
| KS C IEC 60204-1:2016 |
기계류의 안전성-기계의 전기장비-제1부:일반요구사항 18.2.2 시험 1 - 보호 접지 회로의 연속성 검증 18.3 절연 저항 시험 18.4 전압 시험 18.5 잔류 전압 보호 |
보호본딩회로의 연속성 검증 : 최대 10 A 절연저항 : 직류 500 V, (1 ~ 5 000) ㏁ 전압시험 : 교류 (1~5) kV 잔류 전압에 대한 보호 : 최대 500 V |
소재지 |
| ▶ 가정용 전기기기 |
| KC 62368-1:2025 |
오디오/비디오 및 정보통신기술기기 제1부: 안전 요구 사항 (제외항목) - Cl. 4.8 코인/버튼 단전지를 포함하는 기기 - Cl. 5.3.2 전기 에너지원 및 보호수단에 접근 가능성/테스트프로브 V.1, V.4 - Cl. 5.4.1.4 재질 부품 및 시스템에 대한 최대 동작 온도/삼상 전원 제품 - Cl. 5.4.1.5.3 열 사이클링 시험절차 - Cl. 5.4.1.10 전도성 금속부가 직접 장착되어있는 열가소성 부위/연화온도(Vicat)시험 - Cl. 5.4.2, 5.4.3, 5.4.4 Annex X 공간거리, 연면거리, 고체절연/IEC 60112에 따는 비교 트래킹 인덱스/맨드릴 시험 - Cl. 5.5.8 주전원과 동축 케이블로 구성된 외부 회로 사이의 절연 - Cl. 5.6.4.1 과전류 보호장치와 회로의 결정 (부속서 R)/ 1 500A 단락회로 공급원 - Cl. 8.5.4.3 미디어 파기에 대한 전기기계장치를 갖고 있는 기기 - Cl. 8.5.5 고압 램프 - Cl. 8.6.4 유리 경사면 시험 - Cl. 8.8 핸들(손잡이) 강도 - Cl. 9.6 무선 전력 전송기에 대한 요구 사항 - Cl. 10 방사(선) - 부속서 C 자외선(UV radiation) - 부속서 E 오디오 증폭기를 포함한 기기에 대한 시험조건/광대역 잡음 측정용 대역 통과 필터, 핑크 노이즈 신호 발생기 - 부속서 G.5.3.4 FIW(완전 절연 권선)을 사용한 변압기 - 부속서 G.7 주전원 코드/IEC 60227 에 따른 시험장비 - 부속서 G.9 집적회로(IC) 전류 제한기 - 부속서 G.10 저항 - 부속서 G.13.6 코팅 인쇄기판 - 부속서 G.15 가압 액체로 채워진 부품/수압 시험, 튜빙 및 피팅 호환성 시험 - 부속서 G.16 캐패시터 방전 기능을 포함한 집적회로(ICX) - 부속서 J 중간절연 없이 사용하기 위한 절연권선 전선 - 부속서 M.7 납축전지 및 니켈-카드뮴 배터리의 폭발 위험 - 부속서 M.8 수성 전해액 배터리의 외부 스파크 원으로부터 내부 점화에 대한 보호 - 부속서 R 제한 단락 회로 시험 - 부속서 S 내열 및 내화성 시험 - 부속서 T.10 유리 파쇄 시험 - 부속서 U CRTs의 기계적 강도 및 내파 영향에 대한 보호 - 부속서 V.1.2 시험방법1- 관절 시험 프로브로 표면 및 개구부 시험/시험 프로브 V.1 - 부속서 V.1.5 시험방법4- 슬롯 개구부/시험 프로브 V.4 - 부속서 Y.2 자외선에 대한 내성 - 부속서 Y.3 부식에 대한 내성 - 부속서 Y.4 개스킷 - 부속서 Y.5 옥외용 엔클로우저 내의 기기 보호 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| IEC 62368-1:2023 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements (Exception) -Cl. 4.8 Equipment containing coin / button cell batteries -Cl. 5.3.2 Accessibility to electrical energy sources and safeguards/Test probe V1, V4 -Cl. 5.4.1.4 Maximum operating temperatures for materials, components and systems/Three phase voltage supply system -Cl. 5.4.1.5.3 Thermal cycling test procedure -Cl. 5.4.1.10: Thermoplastic parts on which conductive metallic parts are directly mounted/Vicat test B50 of ISO 306 -Cl. 5.4.2 Clearances/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Cl. 5.4.3 Creepage distances/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Cl. 5.4.4 Solid insulation/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Cl. 5.5.8 Insulation between the mains and an external circuit consisting of a coaxial cable -Cl. 5.6.4 Requirements for protective bonding conductors/Annex R Source with at least 1 500 A short circuit -Cl. 8.5.4.3 Equipment having an electromechanical device for destruction of media -Cl. 8.5.5 High pressure lamps -Cl. 8.6.4 Glass slide test -Cl. 8.8 Handle strength -Cl. 9.6 Requirements for wireless power transmitters -Cl. 10 Radiation -Annex C UV radiation -Annex E Test conditions for equipment containing audio amplifiers/Band-pass filter for wide-band noise measurement, pink noise signal generator -Annex G.5.3.4 Transformers using fully insulated winding wire (FIW) -Annex G.7 Main supply cords -Annex G.9 Integrated circuit (IC) current limiters -Annex G.10 Resistors -Annex G.13.6 Test on coated printed boards -Annex G.15 Pressurized liquid filled components/Tubing and fittings compatibility test/Vibration test -Annex G.16 IC that includes a capacitor discharge function (ICX) -Annex J Insulated winding wires for use without interleaved insulation -Annex M.7 Risk of explosion from lead acid and NiCd batteries -Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte -Annex R Limited Short-circuit test -Annex S Test for resistance to heat and fire -Annex T.10 Glass fragmentation test -Annex U Mechanical strength of CRTs and protection against the effects of implosion -Annex V.1.2 Test method 1-Surfaces and openings tested with jointed test probes/Test probe V.1 -Annex V.1.5 Test method 4-Slot openings/Test probe V.4 -Annex X Alternative method for determining clearances for insulation in circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Annex Y.2 Resistance to UV radiation -Annex Y.3 Resistance to corrosion -Annex Y.4 Gaskets -Annex Y.5 Protection of equipment within an outdoor enclosure |
(Single pulse, Frequency: 48 ㎐ - 68 ㎐) 1. Input: Max. 250 V, Max. 20 A 2. Insulation distances: Max. 150 mm / 0.01 mm 3. Insulation resistance: DC 500 V / Max. 5 GΩ 4. Dielectric strength: Max 5 kV 5. Protective earth: Max. 30 A / 0.1 mΩ 6. Heating: Max. 200 ℃ / 0.1 ℃ |
소재지 |
| EN IEC 62368-1:2020/A11:2020 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements (Exception) -Cl. 4.8 Equipment containing coin / button cell batteries -Cl. 5.3.2 Accessibility to electrical energy sources and safeguards/Test probe V1, V4 -Cl. 5.4.1.4 Maximum operating temperatures for materials, components and systems/Three phase voltage supply system -Cl. 5.4.1.5.3 Thermal cycling test procedure -Cl. 5.4.1.10: Thermoplastic parts on which conductive metallic parts are directly mounted/Vicat test B50 of ISO 306 -Cl. 5.4.2 Clearances/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Cl. 5.4.3 Creepage distances/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Cl. 5.4.4 Solid insulation/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Cl. 5.5.8 Insulation between the mains and an external circuit consisting of a coaxial cable -Cl. 5.6.4 Requirements for protective bonding conductors/Annex R Source with at least 1 500 A short circuit -Cl. 8.5.4.3 Equipment having an electromechanical device for destruction of media -Cl. 8.5.5 High pressure lamps -Cl. 8.6.4 Glass slide test -Cl. 8.8 Handle strength -Cl. 9.6 Requirements for wireless power transmitters -Cl. 10 Radiation -Annex C UV radiation -Annex E Test conditions for equipment containing audio amplifiers/Band-pass filter for wide-band noise measurement, pink noise signal generator -Annex G.5.3.4 Transformers using fully insulated winding wire (FIW) -Annex G.7 Main supply cords -Annex G.9 Integrated circuit (IC) current limiters -Annex G.10 Resistors -Annex G.13.6 Test on coated printed boards -Annex G.15 Pressurized liquid filled components/Tubing and fittings compatibility test/Vibration test -Annex G.16 IC that includes a capacitor discharge function (ICX) -Annex J Insulated winding wires for use without interleaved insulation -Annex M.7 Risk of explosion from lead acid and NiCd batteries -Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte -Annex R Limited Short-circuit test -Annex S Test for resistance to heat and fire -Annex T.10 Glass fragmentation test -Annex U Mechanical strength of CRTs and protection against the effects of implosion -Annex V.1.2 Test method 1-Surfaces and openings tested with jointed test probes/Test probe V.1 -Annex V.1.5 Test method 4-Slot openings/Test probe V.4 -Annex X Alternative method for determining clearances for insulation in circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)/Impulse test generator/Test equipment for tracking index per IEC 60112/Mandrel test -Annex Y.2 Resistance to UV radiation -Annex Y.3 Resistance to corrosion -Annex Y.4 Gaskets -Annex Y.5 Protection of equipment within an outdoor enclosure |
(Single pulse, Frequency: 48 ㎐ - 68 ㎐) 1. Input: Max. 250 V, Max. 20 A 2. Insulation distances: Max. 150 mm / 0.01 mm 3. Insulation resistance: DC 500 V / Max. 5 GΩ 4. Dielectric strength: Max 5 kV 5. Protective earth: Max. 30 A / 0.1 mΩ 6. Heating: Max. 200 ℃ / 0.1 ℃ |
소재지 |
| EN IEC 60335-1:2023/A11:2023 |
Household and similar electrical appliances Safety- Part1: General requirements -Safety requirements (Exception) -Cl. 14 Transient overvoltages -Cl. 15.1 IP test -Cl. 19.11.4 EMS test -Cl. 22.3 Construction(torque) -Cl. 22.16 Automatic cord reels -Cl. 22.32 Crack test -Cl. 22.46 Annex R -Cl. 22.47~48 Water mains appliance -Cl. 23.3 Cord durability -Cl. 24.1.1 Annex F -Cl. 24.1.3~24.1.6 Cycle test -Cl. 24.1.9 Contactor and relay test -Cl. 25.14 Supply cord flexing test -Cl. 25.25 Plug dimension -Cl. 32 Radiation, toxicity and similar hazards Annex E Needle-flame test Annex F Capacitors Annex H Switches Annex J Coated printed circuit boards Annex N Proof tracking test Annex R Software evaluation |
(Single pulse, Frequency: 48 ㎐ - 68 ㎐) 1. Input: Max. 250 V, Max. 20 A 2. Insulation distances: Max. 150 mm / 0.01 mm 3. Insulation resistance: DC 500 V / Max. 5 GΩ 4. Dielectric strength: Max 5 kV 5. Protective earth: Max. 30 A / 0.1 mΩ 6. Heating: Max. 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-8:2016 |
가정용 및 이와 유사한 전기기기의 안전성 제2-8부 : 면도기, 이발기 및 이와 유사한 전기 기기의 개별 요구 사항 (제외항목) -Cl. 6.2 IP 시험 -Cl. 24.1.3 스위치 시험 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-14:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-14부 : 주방기기의 개별 요구사항 (제외항목) -Cl. 15.101 무선 블렌더 받침대의 연결장치 -Cl. 19.102 커피 분쇄기 및 곡물 분쇄기 -Cl. 20 안정성 및 기계적 위협 -Cl. 24.1.3 스위치 동작 사이클 시험 -Cl. 25 전원 접속과 외부 유연성 코드 - 부속서 AA 원심 과즙기 회전 체에 대한 대체 시험 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-15:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-15부 : 액체 가열용 전기기기의 개별요구사항 <제외항목> -Cl. 6.2 IP 시험 -Cl. 19.13 압력안전장치 -Cl. 19.102 2개의 자동 리셋 열 차단 장치 -Cl. 22 구조 -Cl. 24.1.3 증류 또는 증기 작동 스위치 -Cl. 24.1.4 자동 리셋 열 차단 장치 -Cl. 24.101 자동복귀형 온도 과승방지 장치 내구성 시험 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-23:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-23부:피부 손질 또는 모발 손질용 전기기기의 개별 요구사항 (제외항목) -Cl. 3.1.9 헬멧형 모발 건조기, 유연성 덮개가 부착된 모발 건조기 시험 -Cl. 6.2 IP 시험 -Cl. 11.101 회전 이음쇠 -Cl. 19.2 저밀도 유리 섬유 절연 -Cl. 19.102 폴리에틸렌 시트 -Cl. 25.101 회전 이음쇠 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-65:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-65부:공기 청정기의 개별 요구사항 (제외항목) -Cl. 16.101 고전압 변압기 -Cl. 22.103 자외선 복사 방출 -Cl. 22.106 유기재료의 UV-C 내성 -Cl. 23.101 내부 배선의 UV-C 내성 -Cl. 24.1.3 인터로크 스위치 -Cl. 32 방사선, 유독성 및 이와 유사한 위험 -부속서 AA 자외선 복사 전처리 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-1:2022(2022-02) |
가정용 및 이와 유사한 전기기기의 안전성 제1부 : 일반요구사항 (제외항목) -Cl. 14 과도과전압 -Cl. 15.1 IP 시험 -Cl. 19.11.4 EMS 시험 -Cl. 22.3 구조(토크) -Cl. 22.16 자동식 코드릴 내구성 시험 -Cl. 22.32 균열시험 -Cl. 22.46 소프트웨어 평가 -Cl. 22.47~48 수도관에 연결되는 기기 시험 -Cl. 22.57 UV-C 방사선 시험 -Cl. 23.3 굽힘 시험 -Cl. 24.1.1 부속서 F 관련사항만 제외 -Cl. 24.1.3~24.1.6 자체 부품 내구성 시험 제외 -Cl. 24.1.9 접촉기와 릴레이 시험 -Cl. 25.14 코드 굴곡 시험 -Cl. 25.25 플러그 치수 -Cl. 32 방사선, 유독성 및 이와 유사한 위험 부속서 E 니들 프레임 시험 부속서 F 커패시터 부속서 H 스위치 부속서 J 피복된 인쇄 회로기판 부속서 N 내트래킹 시험 부속서 R 소프트웨어 평가 부속서 T 비금속 재료에 대한 UV-C 방사 효과 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-1:2022(2022-06) |
가정용 및 이와 유사한 전기기기의 안전성 제1부 : 일반요구사항 (제외항목) -Cl. 14 과도과전압 -Cl. 15.1 IP 시험 -Cl. 19.11.4 EMS 시험 -Cl. 22.3 구조(토크) -Cl. 22.16 자동식 코드릴 내구성 시험 -Cl. 22.32 균열시험 -Cl. 22.46 소프트웨어 평가 -Cl. 22.47~48 수도관에 연결되는 기기 시험 -Cl. 22.57 UV-C 방사선 시험 -Cl. 23.3 굽힘 시험 -Cl. 24.1.1 부속서 F 관련사항만 제외 -Cl. 24.1.3~24.1.6 자체 부품 내구성 시험 제외 -Cl. 24.1.9 접촉기와 릴레이 시험 -Cl. 25.14 코드 굴곡 시험 -Cl. 25.25 플러그 치수 -Cl. 32 방사선, 유독성 및 이와 유사한 위험 부속서 E 니들 프레임 시험 부속서 F 커패시터 부속서 H 스위치 부속서 J 피복된 인쇄 회로기판 부속서 N 내트래킹 시험 부속서 R 소프트웨어 평가 부속서 T 비금속 재료에 대한 UV-C 방사 효과 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-1:2016 |
가정용 및 이와 유사한 전기기기의 안전성 제1부 : 일반요구사항 (제외항목) -Cl. 14 과도과전압 -Cl. 15.1 IP 시험 -Cl. 19.11.4 EMS 시험 -Cl. 22.3 구조(토크) -Cl. 22.16 자동식 코드릴 내구성 시험 -Cl. 22.32 균열시험 -Cl. 22.46 소프트웨어 평가 -Cl. 22.47~48 수도관에 연결되는 기기 시험 -Cl. 23.3 굽힘 시험 -Cl. 24.1.1 부속서 F 관련사항만 제외 -Cl. 24.1.3~24.1.6 자체 부품 내구성 시험 제외 -Cl. 24.1.9 접촉기와 릴레이 시험 -Cl. 25.14 코드 굴곡 시험 -Cl. 25.25 플러그 치수 -Cl. 32 방사선, 유독성 및 이와 유사한 위험 부속서 E 니들 프레임 시험 부속서 F 커패시터 부속서 H 스위치 부속서 J 피복된 인쇄 회로기판 부속서 N 내트래킹 시험 부속서 R 소프트웨어 평가 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| IEC 60335-1:2020/AMD1:2025 |
Household and similar electrical appliances Safety- Part1: General requirements (Exception) -Cl. 14 Transient overvoltages -Cl. 15.1 IP test -Cl. 19.11.4 EMS test -Cl. 22.3 Construction(torque) -Cl. 22.16 Automatic cord reels -Cl. 22.32 Crack test -Cl. 22.46 Software evaluation -Cl. 22.47~48 Water mains appliance -Cl. 22.57 UV-C radiation test -Cl. 23.3 Cord durability -Cl. 24.1.1 Annex F -Cl. 24.1.3~24.1.6 Cycle test -Cl. 24.1.9 Contactor and relay test -Cl. 25.14 Supply cord flexing test -Cl. 25.25 Plug dimension -Cl. 32 Radiation, toxicity and similar hazards Annex E Needle-flame test Annex F Capacitors Annex H Switches Annex J Coated printed circuit boards Annex N Proof tracking test Annex R Software evaluation Annex T UV-C radiation effect on non-metallic materials |
(Single pulse, Frequency: 48 ㎐ - 68 ㎐) 1. Input: Max. 250 V, Max. 20 A 2. Insulation distances: Max. 150 mm / 0.01 mm 3. Insulation resistance: DC 500 V / Max. 5 GΩ 4. Dielectric strength: Max 5 kV 5. Protective earth: Max. 30 A / 0.1 mΩ 6. Heating: Max. 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-80:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-80부: 전기 팬(fan)의 개별요구사항 (제외항목) -Cl. 5.7 열대 기후에서 사용하는 팬 -Cl. 6.2 IP 시험 -Cl. 20.101 쇼어 경도, 날개 주변부의 속도 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-80:2020 |
가정용 및 이와 유사한 전기기기의 안전성 제2-80부: 전기 팬(fan)의 개별요구사항 (제외항목) -Cl. 5.7 열대 기후에서 사용하는 팬 -Cl. 6.2 IP 시험 -Cl. 20.101 쇼어 경도, 날개 주변부의 속도 -Cl. 22.102 천장형 팬의 안전 장치 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| KC 60335-2-80:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-80부: 전기 팬(fan)의 개별요구사항 (제외항목) -Cl. 5.7 열대 기후에서 사용하는 팬 -Cl. 6.2 IP 시험 -Cl. 20.101 쇼어 경도, 날개 주변부의 속도 -Cl. 22.102 천장형 팬의 안전 장치 |
(단상, 주파수: 48 ㎐ - 68 ㎐) 1. 입력: 최대 250 V, 최대 20 A 2. 절연거리: 최대 150 mm / 0.01 mm 3. 절연저항: DC 500 V / 최대 5 GΩ 4. 내전압: 최대 5 kV 5. 보호접지: 최대 30 A / 0.1 mΩ 6. 온도상승: 최대 200 ℃ / 0.1 ℃ |
소재지 |
| ▶ 에너지효율 |
기후에너지환경부 고시 제2026-26호 (2026.01.23.) |
효율관리 기자재 운용규정 제4조 12. 선풍기 20. 어댑터·충전기 |
전압 : 250 V 이하 전류 : 20 A 이하 |
소재지 |