| ▶ 전자기적합성 |
| RTCADO-160G:2010 |
Environmental Conditions and Test Procedures for Airborne Equipment Section 20, Radio Frequency Susceptibility (Radiated and Conducted) Section 21, Emission of Radio Frequency Energy Section 22, Lightning Induced Transient Susceptibility Section 25, Electrostatic Discharge |
CS : 10 kHz ∼ 400 MHz RS : 100 MHz ∼ 18 GHz (Max. 200 V/m) CE : 150 kHz ∼ 6 GHz RE : 100 kHz ∼ 152 MHz 간접낙뢰 : WF1, WF2, WF3, WF4, WF5, WF6 / Pin Injection, Single Stoke, Multiple Stroke, Multiple Burst ESD : ± (2 ∼ 15) kV |
소재지-1 |
| MIL-STD-461G:2015 |
DEPARTMENT OF DEFENSE INTERFACE STANDARD REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT 5.4 CE101, conducted emissions, audio frequency currents, power leads 5.5 CE102, conducted emissions, radio frequency potential, power leads 5.6 CE106, conducted emissions, antenna port 5.7 CS101, conducted susceptibility, power leads 5.11 CS109, conducted susceptibility, structure current 5.12 CS114, conducted susceptibility, bulk cable injection 5.13 CS115, conducted susceptibility, bulk cable injection, impulse excitation 5.14 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads 5.15 CS117, conducted susceptibility, lightning induced transients, cables and power leads 5.16 CS118, personnel borne electrostatic discharge 5.17 RE101, radiated emissions, magnetic field 5.18 RE102, radiated emissions, electric field 5.20 RS101, radiated susceptibility, magnetic field 5.21 RS103, radiated susceptibility, electric field
2 MHz ∼ 100 MHz, 200 V/m |
CE101: 30 Hz ∼ 10 kHz CE102: 10 kHz ∼ 10 MHz CE106: 10 kHz ~ 40 GHz CS101: 30 Hz ∼ 150 kHz CS109: 60 Hz ∼ 100 kHz CS114: 4 kHz ∼ 200 MHz CS115: Impulse 5 A CS116: 10 kHz ∼ 100 MHz CS117: WF1, WF2, WF3, WF4, WF5, WF6 / Multiple Stroke, Multiple Burst CS118: ± (2 ∼ 15) kV RE101: 30 Hz ∼ 100 kHz RE102: 10 kHz ∼ 18 GHz RS101: 30 Hz ∼ 100 kHz RS103: 2 MHz ∼ 18 GHz (Max. 200 V/m) |
소재지-1 |
| MIL-STD-461F:2007 |
DEPARTMENT OF DEFENSE INTERFACE STANDARD REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT 5.4 CE101, conducted emissions, power leads, 30 Hz to 10 kHz 5.5 CE102, conducted emissions, power leads, 10 kHz to 10 MHz 5.6 CE106, conducted emissions, antenna terminal, 10 kHz to 40 GHz 5.7 CS101, conducted susceptibility, power leads, 30 Hz to 150 kHz 5.11 CS106, conducted susceptibility, transients, power leads 5.12 CS109, conducted susceptibility, structure current, 60 Hz to 100 kHz 5.13 CS114, conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz 5.14 CS115, Conducted susceptibility, bulk cable injection, impulse excitation 5.15 CS116, conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz 5.16 RE101, radiated emissions, magnetic field, 30 Hz to 100 kHz 5.17 RE102, radiated emissions, electric field, 10 kHz to 18 GHz 5.19 RS101, radiated susceptibility, magnetic field, 30 Hz to 100 kHz 5.20 RS103, radiated susceptibility, electric field, 2 MHz to 40 GHz
2 MHz ∼ 100 MHz, 200 V/m |
CE101: 30 Hz ∼ 10 kHz CE102: 10 kHz ∼ 10 MHz CE106: 10 kHz ∼ 40 GHz CS101: 30 Hz ∼ 150 kHz CS106: 400 Vpeak CS109: 60 Hz ∼ 100 kHz CS114: 4 kHz ∼ 200 MHz CS115: Impulse 5 A CS116: 10 kHz ∼ 100 MHz RE101: 30 Hz ∼ 100 kHz RE102: 10 kHz ∼ 18 GHz RS101: 30 Hz ∼ 100 kHz RS103: 2 MHz ∼ 18 GHz (Max. 200 V/m) |
소재지-1 |
| ▶ 에너지효율 |
| KS B 8292 : 2023 |
물-물 지열원 열펌프 유닛 (제외항목) 브라인-물 열펌프 유닛 |
정격용량 : 최대 530 kW |
소재지 |
| KS B 6275 : 2018 |
워터 칠링 유닛 6.2 냉각 능력 6.3 냉각 소비 전력 6.4 히트 펌프 가열 능력 6.5 히트 펌프 가열 소비 전력 6.6 전열 장치의 소비 전력 6.13 자동 서리제거 기능 6.14 저온 성능 |
냉각능력 : 최대 100 kW |
소재지 |
| ▶ 환경 및 신뢰성 |
| MIL-STD-810G:2008 |
Department of Defense Test Method Standard : Environmental Engineering Considerations and Laboratory Tests
- Method 500.5 Low Pressure (Altitude)
- Method 501.5 High Temperature
- Method 502.5 Low Temperature
- Method 505.5 Solar Radiation (Sunshine)
- Method 507.5 Humidity
- Method 511.5 Explosive Atmosphere
- Method 513.6 Acceleration
- Method 514.6 Vibration |
Method 500.5 : Altitude (0 ~ 12 200) m Pro III ProIV
Method 501.5 & 502.5 : Temperature (-60 ~ 120) ℃
Method 505.5 : Solar Radiation (0 ~ 1 120) W/m2
Method 507.5 : Humidity (15 ~ 95) % R.H.
Method511.5 Altitude (0 ~ 13 000) m
Method 513.6 : Acceleration (0 ~ 980) m/s2
Method514.6 : Frequency (10 ~ 2 000) Hz |
소재지-1 |
| MIL-STD-810G w/Change 1: 2014 |
Department of Defense Test Method Standard : Environmental Engineering Considerations and Laboratory Tests
- Method 500.6 Low Pressure (Altitude)
- Method 501.6 High Temperature
- Method 502.6 Low Temperature
- Method 505.6 Solar Radiation (Sunshine)
- Method 507.6 Humidity
- Method 511.6 Explosive Atmosphere
- Method 513.7 Acceleration
- Method 514.7 Vibration |
Method 500.6 : Altitude (0 ~ 12 200) m Pro III Pro IV
Method 501.6 & 502.6 : Temperature (-60 ~ 120) ℃
Method 505.6 : Solar Radiation (0 ~ 1 120) W/㎡
Method 507.6 : Humidity (15 ~ 95) % R.H.
Method 511.6 : Altitude (0 ~ 13 000) m
Method 513.7 : Acceleration (0 ~ 980) ㎨
Method 514.7 : Frequency (10 ~ 2 000) Hz |
소재지-1 |
| MIL-STD-810H: 2019 |
Department of Defense Test Method Standard : Environmental Engineering Considerations and Laboratory Tests
- Method 500.6 Low Pressure (Altitude)
- Method 501.7 High Temperature
- Method 502.7 Low Temperature
- Method 505.7 Solar Radiation (Sunshine)
- Method 507.6 Humidity
- Method 511.7 Explosive Atmosphere
- Method 513.8 Acceleration
- Method 514.8 Vibration |
Method 500.6 : Altitude (0 ~ 12 200) m Pro III Pro IV
Method 501.7 & 502.7 : Temperature (-60 ~ 120) ℃
Method 505.7 : Solar Radiation (0 ~ 1 120) W/㎡
Method 507.6 : Humidity (15 ~ 95) % R.H.
Method 511.7 : Altitude (0 ~ 13 000) m
Method 513.8 : Acceleration (0 ~ 980) ㎨
Method 514.8 : Frequency (10 ~ 2 000) Hz |
소재지-1 |
| RTCA/DO-160G: 2010 |
Environmental Conditions and Test Procedures for Airborne Equipment
- Section 4.0 Temperature and Altitude
- Section 6.0 Humidity
- Section 8.0 Vibration
- Section 9.0 Explosive Proofness |
4.0: Temperature (-60 ~ 120) ℃ Altitude (0 ~ 12 200) m Pro III Pro IV
6.0: Humidity (15 ~ 95) % R.H.
8.0: Frequency (10 ~ 2 000) Hz
9.0: Temperature (0 ~ 100) ℃ |
소재지-1 |