| ▶ 계측기기 |
| EN 61010-1:2010+A1:2019 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 1: General requirements [Exception] Cl. 9.3.1: Flammability tests Cl. 10.5.3: Insulating material 2) The Vicat softening test of ISO 306, method A120 Cl. 11.7: Fluid pressure and leakage Cl. 12: Protection against radiation, including laser sources, and against sonic and ultrasonic pressure Cl. 13.2.3: Implosion of cathode ray tubes Annex H: Qualification of conformal coatings for protection against POLLUTION |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 61010-2-040:2015 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials [Exception] Cl. 12.5.1: Sound level Cl. 13.1: Poisonous and injurious gases and substances Cl. 13.101: Other HAZARDS arising from the use of toxic sterilants |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 61010-2-011:2021+A11:2021 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 2-011: Particular requirements for REFRIGERATING EQUIPMENT [Exception] Cl. 11.7.104.4: Scratch test Cl. 11.7.104.5: Unprotected refrigerating systems Cl. 11.7.104.6: Stagnation of leaked FLAMMABLE REFRIGERANT Cl. 11.7.104.8: Transport temperature test |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 61010-2-040:2021 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials [Exception] Cl. 12.5.1: Sound level Cl. 13.1: Poisonous and injurious gases and substances Cl. 13.101: Other HAZARDS arising from the use of toxic sterilants |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 61010-2-051:2021+A11:2021 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 61010-2-081:2020 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 61010-2-101:2022+A11:2022 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment [Exception] 12 Protection against radiation, including laser sources, and against sonic and ultrasonic pressure 13 Protection against liberated gases, explosion and implosion |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 61010-2-201:2018 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 1: General requirements [Exception] Cl. 9.3.1: Flammability tests Cl. 10.5.3: Insulating material 2) The Vicat softening test of ISO 306, method A120 Cl. 11.7: Fluid pressure and leakage Cl. 12: Protection against radiation, including laser sources, and against sonic and ultrasonic pressure Cl. 13.2.3: Implosion of cathode ray tubes Annex H: Qualification of conformal coatings for protection against POLLUTION |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-1:2010 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 1: General requirements [Exception] Cl. 9.3.1: Flammability tests Cl. 10.5.3: Insulating material 2) The Vicat softening test of ISO 306, method A120 Cl. 11.7: Fluid pressure and leakage Cl. 12: Protection against radiation, including laser sources, and against sonic and ultrasonic pressure Cl. 13.2.3: Implosion of cathode ray tubes Annex H: Qualification of conformal coatings for protection against POLLUTION |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-1:2010+A1:2016 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 1: General requirements [Exception] Cl. 9.3.1: Flammability tests Cl. 10.5.3: Insulating material 2) The Vicat softening test of ISO 306, method A120 Cl. 11.7: Fluid pressure and leakage Cl. 12: Protection against radiation, including laser sources, and against sonic and ultrasonic pressure Cl. 13.2.3: Implosion of cathode ray tubes Annex H: Qualification of conformal coatings for protection against POLLUTION |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-2-011:2019 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 2-011: Particular requirements for REFRIGERATING EQUIPMENT [Exception] Cl. 11.7.104.4: Scratch test Cl. 11.7.104.5: Unprotected refrigerating systems Cl. 11.7.104.6: Stagnation of leaked FLAMMABLE REFRIGERANT Cl. 11.7.104.8: Transport temperature test |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-2-040:2015 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials [Exception] Cl. 12.5.1: Sound level Cl. 13.1: Poisonous and injurious gases and substances Cl. 13.101: Other HAZARDS arising from the use of toxic sterilants |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-2-040:2020 |
Safety requirements for electrical equipment for measurement, control, and laboratory use-Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials [Exception] Cl. 12.5.1: Sound level Cl. 13.1: Poisonous and injurious gases and substances Cl. 13.101: Other HAZARDS arising from the use of toxic sterilants |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-2-051:2018 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-2-081:2019 |
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-2-101:2018 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment [Exception] 12 Protection against radiation, including laser sources, and against sonic and ultrasonic pressure 13 Protection against liberated gases, explosion and implosion |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 61010-2-201:2017 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-201: Particular requirements for control equipment |
Input voltage(AC): Max. 500 V Input current(A): Max. 20 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| ▶ 산업용 전기기기 |
| ES-6130-0001:2022 |
충전장치
[제외항목] 6.5.17 전자기적합성(EMC) 시험 |
입력 전압 (AC): 최대 380 V 입력 주파수: 60 Hz 출력 전압(DC): 최대 150 V 출력 전류(DC): 최대 120 A |
소재지-2 |
| KS C 4310:2021 |
무정전 전원장치
[제외항목] 8.4.3 오류 제거 능력-일반모드 8.4.4 오류 제거 능력-충전 에너지 모드 8.5 UPS 출력의 동적 특성 시험 8.6 UPS 출력 특성-기준 비선형 부하 8.7 충전 및 재충전 에너지 |
입력 및 출력 전압 (AC): 최대 440 V 입력 및 출력 주파수: 60 Hz 정격용량 : 단상 100 kVA 이하, 삼상 100 kVA 이하 |
소재지-2 |
| KS C 4402:2003 |
충전용 정류장치
[제외항목] 10.4.8 제어 장치 특성 확인 10.4.13 전기 자기 적합성 시험 |
입력 전압 (AC): 최대 380 V 입력 주파수: 60 Hz 출력 전압(DC): 최대 150 V 출력 전류(DC): 최대 120 A |
소재지-2 |
| KS C IEC 60146-1-1:2002 |
반도체 컨버터 – 일반 요구사항 및 선전류 컨버터 - 제1-1부: 기본 요구사항
[제외항목] 7.5.1.2 유도성 직류 전압 변동 8.2.4 조합체 및 장치의 전력 손실 결정 8.2.11 내외란 시험 8.2.13 무선주파 발생 간섭 및 노이즈 8.2.14 가청 소음 8.2.16 추가시험 |
입력 전압 (AC): 최대 380 V 입력 주파수: 60 Hz 출력 전압(DC): 최대 150 V 출력 전류(DC): 최대 120 A |
소재지-2 |
| KS C IEC 62040-3:2011 |
무정전 전원장치(UPS) - 제3부 : 성능 및 시험방법
[제외항목] 6.4.1.9 예비 발전기 호환성 시험 6.4.1.10 전자기적 호환성 6.4.2.6 직류 성분 6.4.2.10.3 오류제거 능력-일반모드 6.4.2.10.4 오류제거 능력-충전 에니지 모드 6.4.2.11 동적 성능 6.4.3 출력-비선형 부하 6.4.4 충전 및 재충전 에너지 6.5 형식 시험 절차(환경적) 6.6 UPS 기능별 장치 시험(완성품 UPS에서 시험하지 않은) |
입력 및 출력 전압 (AC): 최대 440 V 입력 및 출력 주파수: 60 Hz 정격용량 : 단상 100 kVA 이하, 삼상 100 kVA 이하 |
소재지-2 |
| ▶ 가정용 전기기기 |
| EN 60065:2014 |
Audio, video and similar electronic apparatus — Safety requirements
(Exception) 1.1.2 433 V a.c. in the case of apparatus for connection to a supply other than single-phase 6.1 Ionizing radiation 6.2 Laser radiation 7.2 Heat resistance of insulating material 8.21 Mandrel test 10.2 Surge test 12.3 Remote control devices held in hand 12.5 Antenna coaxial sockets mounted on the apparatus 14.1 Resistors 14.2 Capacitors and RC-units 14.7 Switches 16 External Flexible cord (Test equipment according IEC 60227) 18. Mechanical strength of picture tubes and protection against effects of implosion Annex H insulated winding wires for use without interleaved insulation |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| EN 60065:2014/A11:2017 |
Audio, video and similar electronic apparatus — Safety requirements
(Exception) 1.1.2 433 V a.c. in the case of apparatus for connection to a supply other than single-phase 6.1 Ionizing radiation 6.2 Laser radiation 7.2 Heat resistance of insulating material 8.21 Mandrel test 10.2 Surge test 12.3 Remote control devices held in hand 12.5 Antenna coaxial sockets mounted on the apparatus 14.1 Resistors 14.2 Capacitors and RC-units 14.7 Switches 16 External Flexible cord (Test equipment according IEC 60227) 18. Mechanical strength of picture tubes and protection against effects of implosion Annex H insulated winding wires for use without interleaved insulation |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 |
Household and similar electrical appliances - Safety - Part 1: General requirements [Exception] Cl. 14: Transient overvoltages Cl. 19.11.4: Electromagnetic phenomena test Cl. 22.16: Test for automatic cord reels Cl. 22.32: Oxygen bomb aging test for natural or synthetic rubber Cl. 24.1: Test for components Annex B: 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F: Capacitors Annex H: Switches Annex J: Coated printed circuit boards Annex R: Software evaluation Annex T: UV-C radiation effect on non-metallic materials |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021 |
Household and similar electrical appliances - Safety - Part 2-15: Particular requirements for appliances for heating liquids |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-21:2021 + A1:2021 |
Household and similar electrical appliances - Safety - Part 2-21: Particular requirements for storage water heaters |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-23:2003 + A1:2008 + A11:2010 + AC:2012 + A2:2015 |
Household and similar electrical appliances - Safety - Part 2-23: Particular requirements for appliances for skin or hair care |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-24:2010 + A1:2019 + A2:2019 +A11:2020 |
Household and similar electrical appliances - Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers [Exception] Cl. 22.107.3: Salt mist test Cl. 22.108: Tests of IEC 60079-15 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-25:2021+A11:2021 |
Household and similar electrical appliances - Safety - Part 2-25: Particular requirements for microwave ovens, including combination microwave ovens [Exception] Annex BB: Microwave ovens intended to be used on board ships |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-6:2015 + A1:2020 + A11:2020 |
Household and similar electrical appliances - Safety - Part 2-6 : Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances [Exception] Cl. 32: Radiation, toxicity and similar hazards |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-65:2003 + A1:2008 + A11:2012 |
Household and similar electrical appliances – Safety – Part 2-65: Particular requirements for air-cleaning appliances [Exception] 16.101 High voltage transformer 23 Internal wiring 32 Radiation, toxicity and similar hazards Annex AA: UV radiation test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-65:2003 + A1:2008 + A11:2012 + A12:2022 + A2:2022 |
Household and similar electrical appliances – Safety – Part 2-65: Particular requirements for air-cleaning appliances [Exception] 16.101 High voltage transformer 23 Internal wiring 32 Radiation, toxicity and similar hazards Annex AA: UV radiation test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-7:2010 + A1:2013 +A11:2013 + A2:2019 |
Household and similar electrical appliances - Safety - Part 2-7 : Particular requirements for washing machines [Exception] Cl. 18: Endurance Cl. 22.6: Construction Annex BB: Ageing test for elastomeric parts |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-80:2003+A1:2004+A2:2009 |
Household and similar electrical appliances - Safety - Part 2-80: Particular requirements for fans [Exception] Cl.3.1.9 Duct fans Normal operation |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60335-2-9:2003 + A1:2004 + A2:2006 + A12:2007 + A13:2010 |
Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances [Exception] Cl. 31: Salt mist test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN 60950-1:2006/AMD2:2013 |
Information technology equipment - Safety - Part 1: General requirements
(Exception) 2.10.3.9 Measurement of transient levels 2.10.5.4 Semiconductor devices 3.2.5.1 AC Power supply cords 4.2.8 Cathode ray tube 4.3.12 Flammable liquids 4.3.13.2 Ionizing radiation 4.3.13.3 Effect of UV radiation on materials 4.3.13.4 Human exposure to UV radiation 4.3.13.5.1 Laser 7.4.2 Voltage surge test A.3 Hot flaming oil test Annex AA Mandrel test |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| EN IEC 60335-2-11:2022+A11:2022 |
Household and similar electrical appliances - Safety - Part 2-11: Particular requirements for tumble dryers [Exception] Annex BB: Tests of IEC 60079-15 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 60335-2-23:2023 + A11:2023 + A1:2023 |
Household and similar electrical appliances - Safety - Part 2-23: Particular requirements for appliances for skin or hair care |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 60335-2-24:2022 + A11:2022 |
Household and similar electrical appliances - Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers [Exception] Cl. 22.107.3: Salt mist test Cl. 22.108: Tests of IEC 60079-15 Annex EE: Test for material encasing and in contact with thermal insulation |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 60335-2-89:2022 |
Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances and ice-makers with an incorporated or remote refrigerant unit or motor-compressor [Exception] 22.101 lampholders 22.111, 22.112 & 22.113 flammable refrigerants 22.116 & Annex CC leak of refrigerants 22.119 capped valves and capped service |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 60335-2-9:2023 + A11:2023 |
Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances [Exception] Cl. 31: Salt mist test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 62368-1:2020/A11:2020 |
Audio/video, information and communication technology equipment –Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.1.4, 9.2.5 Maximum operating temperatures for materials, components and systems / Three phase voltage supply systems 5.4.1.5.3 Thermal cycling test procedure 5.4.2, 5.4.3, 5.4.4 Clearances, creepage distance, solid insulation / Test equipment for tracking index per IEC 60112 5.4.2, 5.4.3, 5.4.4, Annex X Clearances, creepage distance, solid insulation / Test equipment for tracking index per IEC 60112 / Mandrel (figure 25 to 28), metal foil, equipment suitable for electrical strength test loads Stop watch, weight 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex G.5.3.4 Test for FIW Annex G.7 Annex G.9 Annex G.10 Annex G.13.6.2 Annex G.15.3.1 Annex G.15.3.3 Annex J Annex M.7 Annex M.8.2 Annex R Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Annex Y.2 Ultraviolet light conditioning test Annex Y.3 Construction requirements for outdoor enclosures (test) Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression test Annex Y.4.5 Oil resistance (test) |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| EN IEC 62368-1:2020+A11:2020 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements [Exception] Cl. 5.4.1.10.2: Vicat test B50 of ISO 306 Cl. 5.4.4.6.5: Mandrel test Cl. 5.6.4.1: Determination of the overcurrent protective device and circuit (Annex R Limited shortcircuit test) Cl. 10: Radiations Annex C: UV radiation Annex G.5.3.4: Transformers using fully insulated winding wire (FIW) Annex G.7.1: Test of IEC 60227 Annex G.9: Integrated circuit(IC) current limiters Annex G.15: Pressurized liquid filled components Annex J: Insulated winding wires for use without interleaved insulation Annex M.7: Risk of explosion from lead acid and NiCd batteries Annex M.8: Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R: Limited short-circuit test Annex S.3: Flammability test for the bottom of a fire enclosure Annex U: Mechanical strength of CRTs and protection against the effects of implosion Annex Y.2: Resistance to UV radiation Annex Y.3: Resistance to corrosion Annex Y.4: Gaskets |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 62368-1:2024/A11:2024 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements [Exception] Cl. 5.4.1.10.2: Vicat test B50 of ISO 306 Cl. 5.4.4.6.5: Mandrel test Cl. 5.6.4.1: Determination of the overcurrent protective device and circuit (Annex R Limited shortcircuit test) Cl. 10: Radiations Annex C: UV radiation Annex G.5.3.4: Transformers using fully insulated winding wire (FIW) Annex G.7.1: Test of IEC 60227 Annex G.9: Integrated circuit(IC) current limiters Annex G.15: Pressurized liquid filled components Annex J: Insulated winding wires for use without interleaved insulation Annex M.7: Risk of explosion from lead acid and NiCd batteries Annex M.8: Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R: Limited short-circuit test Annex S.3: Flammability test for the bottom of a fire enclosure Annex U: Mechanical strength of CRTs and protection against the effects of implosion Annex Y.2: Resistance to UV radiation Annex Y.3: Resistance to corrosion Annex Y.4: Gaskets |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| EN IEC 62368-3:2020 |
Audio/video, information and communication technology equipment - Part 3: Safety aspects for DC power transfer through communication cables and ports |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60065:2014 |
Audio, video and similar electronic apparatus — Safety requirements
(Exception) 1.1.2 433 V a.c. in the case of apparatus for connection to a supply other than single-phase 6.1 Ionizing radiation 6.2 Laser radiation 7.2 Heat resistance of insulating material 8.21 Mandrel test 10.2 Surge test 12.3 Remote control devices held in hand 12.5 Antenna coaxial sockets mounted on the apparatus 14.1 Resistors 14.2 Capacitors and RC-units 14.7 Switches 16 External Flexible cord (Test equipment according IEC 60227) 18. Mechanical strength of picture tubes and protection against effects of implosion Annex H insulated winding wires for use without interleaved insulation |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| IEC 60335-1:2010 |
Household and similar electrical appliances - Safety - Part 1: General requirements [Exception] Cl. 14: Transient overvoltages Cl. 19.11.4: Electromagnetic phenomena test Cl. 22.16: Test for automatic cord reels Cl. 22.32: Oxygen bomb aging test for natural or synthetic rubber Cl. 24.1: Test for components Annex B: 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F: Capacitors Annex H: Switches Annex J: Coated printed circuit boards Annex R: Software evaluation Annex T: UV-C radiation effect on non-metallic materials |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-1:2010+A1:2013 |
Household and similar electrical appliances - Safety - Part 1: General requirements [Exception] Cl. 14: Transient overvoltages Cl. 19.11.4: Electromagnetic phenomena test Cl. 22.16: Test for automatic cord reels Cl. 22.32: Oxygen bomb aging test for natural or synthetic rubber Cl. 24.1: Test for components Annex B: 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F: Capacitors Annex H: Switches Annex J: Coated printed circuit boards Annex R: Software evaluation Annex T: UV-C radiation effect on non-metallic materials |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-1:2010+A1:2013+A2:2016 |
Household and similar electrical appliances - Safety - Part 1: General requirements [Exception] Cl. 14: Transient overvoltages Cl. 19.11.4: Electromagnetic phenomena test Cl. 22.16: Test for automatic cord reels Cl. 22.32: Oxygen bomb aging test for natural or synthetic rubber Cl. 24.1: Test for components Annex B: 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F: Capacitors Annex H: Switches Annex J: Coated printed circuit boards Annex R: Software evaluation Annex T: UV-C radiation effect on non-metallic materials |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-1:2020 |
Household and similar electrical appliances – Safety – Part 1: General requirements
[Exception] 5.19 Measurements of cell voltages or battery voltages 8.1.4 Protection against access to live parts - note 2 14 Impulse test voltage over 6 000 V 19.11.4.7 Mains signal test in accordance with IEC 61000-4-13 21.2 Scratch test 22.7 Pressure test 22.16 Test for automatic cord reels 22.32 Oxygen bomb aging test for natural or synthetic rubber 22.46 Software evaluation 22.48 Relevant test of IEC 61770 23 Internal wiring (flexing test) 24 Components (test) 25 Supply connection and external flexible cords (flexing test) Annex B Annex C Annex F Annex G Annex H Annex J Annex N Annex R Annex T Annex U |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| IEC 60335-1:2020 |
Household and similar electrical appliances - Safety - Part 1: General requirements [Exception] Cl. 14: Transient overvoltages Cl. 19.11.4: Electromagnetic phenomena test Cl. 22.16: Test for automatic cord reels Cl. 22.32: Oxygen bomb aging test for natural or synthetic rubber Cl. 24.1: Test for components Annex B: 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F: Capacitors Annex H: Switches Annex J: Coated printed circuit boards Annex R: Software evaluation Annex T: UV-C radiation effect on non-metallic materials |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-11:2024 |
Household and similar electrical appliances - Safety - Part 2-11: Particular requirements for tumble dryers [Exception] Annex BB: Tests of IEC 60079-15 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-113:2016 |
Household and similar electrical appliances - Safety - Part 2-113: Particular requirements for beauty care appliances incorporating lasers and intense light sources [Exception] Cl. 32.101: Laser emission level test Cl. 32.102: Stray optical radiation emission level test Annex R: Software evaluation |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-113:2016+A1:2021 |
Household and similar electrical appliances - Safety - Part 2-113: Particular requirements for beauty care appliances incorporating lasers and intense light sources [Exception] Cl. 32.101: Laser emission level test Cl. 32.102: Stray optical radiation emission level test Annex R: Software evaluation |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-15:2012 |
Household and similar electrical appliances - Safety - Part 2-15: Particular requirements for appliances for heating liquids |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-15:2012+A1:2016 |
Household and similar electrical appliances - Safety - Part 2-15: Particular requirements for appliances for heating liquids |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-15:2024 |
Household and similar electrical appliances - Safety - Part 2-15: Particular requirements for appliances for heating liquids |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-17:2012/AMD1:2015 |
Household and similar electrical appliances - Safety - Part 2-17: Particular requirements for blankets, pads, clothing and similar flexible heating appliances
[Exception] 21.104 Mechanical strength of mattresses 21.106 Mechanical strength of flexible part 21.107 Drop test of pads 21.109, 21.110 Mechanical strength for the enclosure of moisture-proof appliances Annex CC Clothing |
Input Voltage: Max. 250 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| IEC 60335-2-21:2022 |
Household and similar electrical appliances - Safety - Part 2-21: Particular requirements for storage water heaters |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-23:2016 |
Household and similar electrical appliances - Safety - Part 2-23: Particular requirements for appliances for skin or hair care |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-23:2016+A1:2019 |
Household and similar electrical appliances - Safety - Part 2-23: Particular requirements for appliances for skin or hair care |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-24:2025 |
Household and similar electrical appliances - Safety - Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers [Exception] Cl. 22.107.3: Salt mist test Cl. 22.108: Tests of IEC 60079-15 Annex EE: Test for material encasing and in contact with thermal insulation |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-25:2024 |
Household and similar electrical appliances - Safety - Part 2-25: Particular requirements for microwave ovens, including combination microwave ovens [Exception] Annex BB: Microwave ovens intended to be used on board ships |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-6:2014 |
Household and similar electrical appliances - Safety - Part 2-6 : Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances [Exception] Cl. 32: Radiation, toxicity and similar hazards |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-6:2024 |
Household and similar electrical appliances - Safety - Part 2-6 : Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances [Exception] Cl. 32: Radiation, toxicity and similar hazards |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-65:2002 |
Household and similar electrical appliances – Safety – Part 2-65: Particular requirements for air-cleaning appliances [Exception] 16.101 High voltage transformer 23 Internal wiring 32 Radiation, toxicity and similar hazards Annex AA: UV radiation test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-65:2002+A1:2008 |
Household and similar electrical appliances – Safety – Part 2-65: Particular requirements for air-cleaning appliances [Exception] 16.101 High voltage transformer 23 Internal wiring 32 Radiation, toxicity and similar hazards Annex AA: UV radiation test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-65:2023 |
Household and similar electrical appliances – Safety – Part 2-65: Particular requirements for air-cleaning appliances [Exception] 16.101 High voltage transformer 23 Internal wiring 32 Radiation, toxicity and similar hazards Annex AA: UV radiation test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-7:2024 |
Household and similar electrical appliances - Safety - Part 2-7 : Particular requirements for washing machines [Exception] Cl. 18: Endurance Cl. 22.6: Construction Annex BB: Ageing test for elastomeric parts |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-80:2024 |
Household and similar electrical appliances - Safety - Part 2-80: Particular requirements for fans [Exception] Cl.3.1.9 Duct fans Normal operation |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-89:2019 |
Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances and ice-makers with an incorporated or remote refrigerant unit or motor-compressor [Exception] 22.101 lampholders 22.111, 22.112 & 22.113 flammable refrigerants 22.116 & Annex CC leak of refrigerants 22.119 capped valves and capped service |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60335-2-9:2019 |
Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances [Exception] Cl. 31: Salt mist test |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 60950-1:2005+AMD1:2009+AMD2:2013 |
Information technology equipment - Safety - Part 1: General requirements
(Exception) 2.10.3.9 Measurement of transient levels 2.10.5.4 Semiconductor devices 3.2.5.1 AC Power supply cords 4.2.8 Cathode ray tube 4.3.12 Flammable liquids 4.3.13.2 Ionizing radiation 4.3.13.3 Effect of UV radiation on materials 4.3.13.4 Human exposure to UV radiation 4.3.13.5.1 Laser 7.4.2 Voltage surge test A.3 Hot flaming oil test Annex AA Mandrel test |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| IEC 62368-1:2014 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements [Exception] Cl. 5.4.1.10.2: Vicat test B50 of ISO 306 Cl. 5.4.4.6.5: Mandrel test Cl. 5.6.4.1: Determination of the overcurrent protective device and circuit (Annex R Limited shortcircuit test) Cl. 10: Radiations Annex C: UV radiation Annex G.7.1: Test of IEC 60227 Annex G.9: Integrated circuit(IC) current limiters Annex G.15: Pressurized liquid filled components Annex J: Insulated winding wires for use without interleaved insulation Annex M.7: Risk of explosion from lead acid and NiCd batteries Annex M.8: Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R: Limited short-circuit test Annex S.3: Flammability test for the bottom of a fire enclosure Annex U: Mechanical strength of CRTs and protection against the effects of implosion |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 62368-1:2018 |
Audio/video, information and communication technology equipment –Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.1.4, 9.2.5 Maximum operating temperatures for materials, components and systems / Three phase voltage supply systems 5.4.1.5.3 Thermal cycling test procedure 5.4.2, 5.4.3, 5.4.4 Clearances, creepage distance, solid insulation / Test equipment for tracking index per IEC 60112 5.4.2, 5.4.3, 5.4.4, Annex X Clearances, creepage distance, solid insulation / Test equipment for tracking index per IEC 60112 / Mandrel (figure 25 to 28), metal foil, equipment suitable for electrical strength test loads Stop watch, weight 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex G.5.3.4 Test for FIW Annex G.7 Annex G.9 Annex G.10 Annex G.13.6.2 Annex G.15.3.1 Annex G.15.3.3 Annex J Annex M.7 Annex M.8.2 Annex R Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Annex Y.2 Ultraviolet light conditioning test Annex Y.3 Construction requirements for outdoor enclosures (test) Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression test Annex Y.4.5 Oil resistance (test) |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ Temperature: (-30 ∼ 200) °C Humidity: Max. 95 % R.H. |
소재지 |
| IEC 62368-1:2018 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements [Exception] Cl. 5.4.1.10.2: Vicat test B50 of ISO 306 Cl. 5.4.4.6.5: Mandrel test Cl. 5.6.4.1: Determination of the overcurrent protective device and circuit (Annex R Limited shortcircuit test) Cl. 10: Radiations Annex C: UV radiation Annex G.5.3.4: Transformers using fully insulated winding wire (FIW) Annex G.7.1: Test of IEC 60227 Annex G.9: Integrated circuit(IC) current limiters Annex G.15: Pressurized liquid filled components Annex J: Insulated winding wires for use without interleaved insulation Annex M.7: Risk of explosion from lead acid and NiCd batteries Annex M.8: Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R: Limited short-circuit test Annex S.3: Flammability test for the bottom of a fire enclosure Annex U: Mechanical strength of CRTs and protection against the effects of implosion Annex Y.2: Resistance to UV radiation Annex Y.3: Resistance to corrosion Annex Y.4: Gaskets |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 62368-1:2023 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements [Exception] Cl. 5.4.1.10.2: Vicat test B50 of ISO 306 Cl. 5.4.4.6.5: Mandrel test Cl. 5.6.4.1: Determination of the overcurrent protective device and circuit (Annex R Limited shortcircuit test) Cl. 10: Radiations Annex C: UV radiation Annex G.5.3.4: Transformers using fully insulated winding wire (FIW) Annex G.7.1: Test of IEC 60227 Annex G.9: Integrated circuit(IC) current limiters Annex G.15: Pressurized liquid filled components Annex J: Insulated winding wires for use without interleaved insulation Annex M.7: Risk of explosion from lead acid and NiCd batteries Annex M.8: Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R: Limited short-circuit test Annex S.3: Flammability test for the bottom of a fire enclosure Annex U: Mechanical strength of CRTs and protection against the effects of implosion Annex Y.2: Resistance to UV radiation Annex Y.3: Resistance to corrosion Annex Y.4: Gaskets |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| IEC 62368-3:2017 |
Audio/video, information and communication technology equipment - Part 3: Safety aspects for DC power transfer through communication cables and ports |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-1:2022 |
가정용 및 이와 유사한 전기기기의 안전성 - 제1부 : 일반요구사항 [제외항목] Cl. 14: 과도 과전압 Cl. 19.11.4: 전자기 현상 시험 Cl. 22.16: 자동식 코드 릴 시험 Cl. 22.32: 천연 또는 합성고무+J61의 산소 노화시험 Cl. 24.1: 부품 시험 부속서 B: 21.B.101 (KS C IEC 60068-2-31의 자유 낙하 반복시험, 절차 2) 부속서 F: 커패시터 부속서 H: 스위치 부속서 J: 피복된 인쇄 회로기판 부속서 R: 소프트웨어 평가 부속서 T: 비금속 재료에 대한 UV-C 방사 효과 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-1:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제1부: 일반 요구사항
[제외항목] 8.1.4 충전부에 대한 접근 방지 - 비고 2 14 6,000V를 초과하는 임펄스 시험 전압 19.11.4.7 IEC 61000-4-13에 따른 주전원 신호 시험 21.2 스크래치 테스트 22.7 압력 시험 22.16 자동 코드 릴에 대한 시험 22.32 천연고무 또는 합성고무의 산소폭탄 노화시험 22.46 소프트웨어 평가 22.48 IEC 61770 관련 시험 23 내부배선(굴곡시험) 24개 구성요소(테스트) 25 공급 연결 및 외부 유연성 코드(굴곡 테스트) 부속서 B 21 기계적 강도 부록 C 부록 F 부속서 G 부록 H 부속서 I 부속서 J 부속서 N 부속서 R 부록 T |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 20 kV 누설전류: 최대 10 mA 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4 000 MΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60335-2-11:2021 |
가정용 및 이와 유사한 전기기기의 안전성 제2-11부: 회전식 건조기의 개별요구사항 [제외항목] 부속서 CC: IEC 60079-15 시험 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-15:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-15부: 액체가열용 전기기기의 개별 요구사항 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-17:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-17부: 모포, 패드 및 이와 유사한 유연성을 가진 전열기기의 개별요구사항
[제외항목] 21.103 패드의 기계적 강도 시험 21.104 매트리스의 기계적 강도 시험 21.106 유연부에 대한 기계적 강도 시험 21.107 패드 낙하 시험 21.109, 21.110 방수 기능 기기의 외곽에 대한 기계적 강도 시험 부속서 CC 의류 |
입력전압: 최대 250 V 입력전류: 최대 20 A 동작전압: 최대 peak 20 kV 누설전류: 최대 10 mA 접지연속성: 최대 12 V, 최대 60 A 절연내력: 최대 5 kV, 최대 100 mA 절연저항: 최대 4 000 MΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60335-2-21:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-21부: 전기온수기의 개별 요구사항 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-23:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-23부: 피부 손질 또는 모발 손질용 전기기기의 개별 요구사항 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-24:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-24부: 전기냉장고, 아이스크림기기 및 제빙기의 개별요구사항 [제외항목] Cl. 22.107.3: 염수분무 시험 Cl. 22.108: IEC 60079-15 시험 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-25:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-25부: 전자레인지의 개별요구사항 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-6:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-6부: 거치형 조리레인지, 호브, 오븐 및 이와 유사한 기기의 개별요구사항 [제외항목] Cl. 32: 방사선, 유독성 및 이와 유사한 위험성 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-65:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-65부: 공기청정기의 개별 요구사항
[제외항목] 16.101 고전압 변압기 23 내부 배선 32 방사선, 유독성 및 이와 유사한 위험 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 20 kV 누설전류: 최대 10 mA 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4 000 MΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60335-2-65:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-65부: 공기청정기의 개별 요구사항 [제외항목] 16.101 고전압 변압기 23 내부 배선 32 방사선, 유독성 및 이와 유사한 위험 부속서 AA: 자외선 복사 전처리 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-7:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-7부: 전기세탁기의 개별 요구사항 [제외항목] Cl. 18: 내구성 Cl. 22.6: 구조 부속서 BB: 탄성체 부분에 대한 노화 시험 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 60335-2-80:2022 |
가정용 및 이와 유사한 전기기기의 안전성 - 제2-80부: 전기팬(fan)의 개별 요구사항 [제외항목] Cl.3.1.9 덕트형 팬의 통상 동작 |
입력 전압(AC): 최대 500 V 입력 주파수: (50/60) Hz 입력 전류(A): 최대 20 A 누설전류: 최대 500 mA 절연내력: 10 kV 습도: 최대 95 % R.H. 접지연속성: 6 V, 60 A 온도: 최대 200 ℃ 길이: 최대 1 500 mm |
소재지-2 |
| KC 60335-2-9:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-9부: 그릴, 토스터기 및 이와 유사한 휴대용 조리기기의 개별 요구사항 [제외항목] Cl. 31 : 염수분무시험 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KC 62368-1:2025 |
Audio/video, information and communication technology equipment –Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.1.4, 9.2.5 Maximum operating temperatures for materials, components and systems / Three phase voltage supply systems 5.4.1.5.3 Thermal cycling test procedure 5.4.2, 5.4.3, 5.4.4 Clearances, creepage distance, solid insulation / Test equipment for tracking index per IEC 60112 5.4.2, 5.4.3, 5.4.4, Annex X Clearances, creepage distance, solid insulation / Test equipment for tracking index per IEC 60112 / Mandrel (figure 25 to 28), metal foil, equipment suitable for electrical strength test loads Stop watch, weight 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex G.5.3.4 Test for FIW Annex G.7 Annex G.9 Annex G.10 Annex G.13.6.2 Annex G.15.3.1 Annex G.15.3.3 Annex J Annex M.7 Annex M.8.2 Annex R Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Annex Y.2 Ultraviolet light conditioning test Annex Y.3 Construction requirements for outdoor enclosures (test) Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression test Annex Y.4.5 Oil resistance (test) |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 20 kV 누설전류: 최대 10 mA 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4 000 MΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 62368-1:2025 |
오디오/비디오 및 정보통신기술기기 제1부 : 안전 요구 사항 [제외항목] Cl. 5.4.1.10.2: KS M ISO 306의 연화 온도(Vicat) 시험 B50 Cl. 5.4.4.6.5: 맨드릴(mandrel) 시험 Cl. 5.6.4.1: 과전류 보호수단 및 회로의 결정 (부속서 R) Cl. 10: 방사(선) 부속서 C: 자외선 부속서 G.5.3.4: FIW(완전 절연 권선) 을 사용한 변압기 부속서 G.7.1: KS C IEC 60227에 따른 시험 부속서 G.9: 집적회로(IC) 전류 제한기 부속서 G.15: 가압 액체로 채워진 부품 부속서 J: 중간절연 없이 사용하기 위한 절연권선 전선 부속서 M.7: 납축전지 및 니켈-카드뮴 배터리의 폭발 위험 부속서 M.8: 수성 전해액 배터리의 외부 스파크 원으로부터 내부 점화에 대한 보호 부속서 R: 제한 단락 회로 시험 부속서 S.3: 방화용 엔클로우저의 바닥에 대한 난연성 시험 부속서 U: CRTs의 기계적 강도 및 내파 영향에 대한 보호 부속서 Y.2: 자외선에 대한 내성 부속서 Y.3: 부식에 대한 내성 부속서 Y.4: 개스킷 |
Input voltage(AC): Max. 500 V Input Frequency: (50/60) Hz Input current(A): Max. 20 A Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 1 500 mm |
소재지-2 |
| KS C IEC 60065:2014 |
오디오, 비디오기기 및 이와 유사한 전자기기의 안전 (제외항목) 1.1.2 단상 이외의 전원에 연결되는 기기에 있어서는 교류 433 V 6.1 이온화 방사 6.2 레이저 방사 7.2 절연물의 내열성 8.21 비분리 얇은 시트 절연의 시험 규정 10.1 서지 시험 12.3 손으로 조작하는 원격 조정장치 12.5 기기에 부착된 안테나 동축 접속기 14.1 저항 14.2 커패시터 및 R-C 유닛 14.6 스위치 16 외부 유연성 코드 18 브라운관의 기계적 강도 및 폭축의 영향에 대한 보호 부속서 H(규정) 사이에 끼우는 절연 없이 사용하는 절연된 권선용 전선 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 20 kV 누설전류: 최대 10 mA 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4 000 MΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 60950-1:2013 |
정보기술 기기의 안전성-제1부:일반 요구사항
(제외항목) 2.10.3.9 과도 전압 측정 2.10.5.4 반도체 장치 3.2.5.1 AC 전원 코드 4.2.8 브라운관 4.3.12 가연성 액체 4.3.13.2 이온화 방사 4.3.13.3 재질에 대한 자외선 영향 4.3.13.4 자외선의 인체 노출 4.3.13.5.1 레이저(레이저 다이오드 포함) 7.4.2 전압 서지 시험 A.3 점화유 시험 부속서 AA(규정) 맨드릴 시험 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 20 kV 누설전류: 최대 10 mA 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4 000 MΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| ▶ 유/무선 통신기기 |
| EN 300 328 V2.2.2:2019 |
Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum |
30 MHz ~ 12.75 GHz |
소재지-1 |
| QCVN 54:2020/BTTTT |
National technical regulation on wideband data transmission equipment operating in the 2.4 GHz band. |
30 MHz ~ 12.75 GHz |
소재지-1 |
| ▶ 조명기기 |
| EN 60598-2-2:2012 |
Luminaires - Part 2-2: Particular requirements - Recessed luminaires |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN 60598-2-3:2003+AMD1:2011 |
Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN 60598-2-4:2018 |
Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. Cap gauge: E26, E27, B22d |
소재지 |
| EN 60598-2-5:2015 |
Luminaires - Part 2-5: Particular requirements - Floodlights |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN 60968:2015 |
Self-ballasted lamps for general lighting services - Safety requirements |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. Cap gauge: E26, E27, B22d |
소재지 |
| EN 61347-1:2015 |
Lamp control gear - Part 1: General and safety requirements
(Exception) 13 Thermal endurance test for windings of ballasts Annex H.4 Magnetic effects |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN 61347-1:2015/AMD1:2021 |
Lamp control gear - Part 1: General and safety requirements
(Exception) 13 Thermal endurance test for windings of ballasts Annex B, Annex C, Annex D, Annex G, Annex H.4 Magnetic effects, Annex I |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN 61347-2-13:2014+AMD1:2017 |
Lamp control gear - Part2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
(Exception) Annex H.4 Magnetic effects |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN 62031:2008+AMD1:2013+AMD2:2015 |
LED modules for general lighting - Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN 62471:2008 |
Photobiological safety of lamps and lamp systems |
Input Voltage: Max 600 V Input Current: Max 20 A Spectral irradiance : (200 ~ 2 400) nm Spectral radiance : (300 ~ 1 400) nm |
소재지 |
| EN 62471-5:2015 |
Photobiological safety of lamps and lamp systems — Part 5: Image projectors |
Input Voltage: Max 600 V Input Current: Max 20 A Spectral irradiance : (200 ~ 2 400) nm Spectral radiance : (300 ~ 1 400) nm |
소재지 |
| EN 62776:2015 |
Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-40 ∼ 200) °C Humidity: Max 95 % R.H. Total Luminousflux: Max 250 000 lm Color Rendering: Max 100 Color Temperature: Max 10 000 K Spectral radiance : (300 ~ 1 400) nm Total Luminousflux: Max 1 200 lm |
소재지 |
| EN IEC 60598-1:2021 |
Luminaires - Part 1: General requirements and tests
(Exception) 4.10.4 Y1, Y2 capacitors 12.5 Thermal test (C1, C2) |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN IEC 60598-1:2021/AMD:2022 |
Luminaires - Part 1: General requirements and tests
(Exception) 4.10.4 Y1, Y2 capacitors 12.5 Thermal test (C1, C2)
Annex B, Annex C, Annex E |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN IEC 60598-2-1:2021 |
Luminaires - Part 2: Particular requirements Section one - Fixed general purpose luminaires |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN IEC 62031:2020 |
LED modules for general lighting - Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| EN IEC 62031:2020/A11:2021 |
LED modules for general lighting - Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-1:2014+AMD1:2017 |
Luminaires - Part 1: General requirements and tests
(Exception) 4.10.4 Y1, Y2 capacitors 12.5 Thermal test (C1, C2) |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-1:2020 |
Luminaires - Part 1: General requirements and tests
(Exception) 4.10.4 Y1, Y2 capacitors 12.5 Thermal test (C1, C2)
Annex B, Annex C, Annex E |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-2-1:1979/AMD1:1987 |
Luminaires - Part 2: Particular requirements Section one - Fixed general purpose luminaires |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-2-1:2020 |
Luminaires - Part 2: Particular requirements - Fixed general purpose luminaires |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-2-2:2011 |
Luminaires - Part 2-2: Particular requirements - Recessed luminaires |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-2-3:2002+AMD1:2011 |
Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-2-4:2017 |
Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60598-2-5:2015 |
Luminaires - Part 2-5: Particular requirements - Floodlights |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 60968:2015 |
Self-ballasted lamps for general lighting services - Safety requirements |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. Cap gauge: E26, E27, B22d |
소재지 |
| IEC 61347-1:2015+AMD1:2017 |
Lamp control gear - Part 1: General and safety requirements
(Exception) 13 Thermal endurance test for windings of ballasts Annex B, Annex C, Annex D, Annex G, Annex H.4 Magnetic effects, Annex I |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. Cap gauge: E26, E27, B22d |
소재지 |
| IEC 61347-2-13:2014+AMD1:2016 |
Lamp control gear - Part2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
(Exception) Annex H.4 Magnetic effects |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 62031:2018 |
LED modules for general lighting - Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 62471:2006 |
Photobiological safety of lamps and lamp systems |
Input Voltage: Max 600 V Input Current: Max 20 A Spectral irradiance : (200 ~ 2 400) nm Spectral radiance : (300 ~ 1 400) nm |
소재지 |
| IEC 62471-5:2015 |
Photobiological safety of lamps and lamp systems — Part 5: Image projectors |
Input Voltage: Max 600 V Input Current: Max 20 A Spectral irradiance : (200 ~ 2 400) nm Spectral radiance : (300 ~ 1 400) nm |
소재지 |
| IEC 62560:2011 |
Self-ballasted LED-lamps for general lighting services by voltage > 50 V -Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 62560:2011/AMD1:2015 |
Self-ballasted LED-lamps for general lighting services by voltage > 50 V -Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-30 ∼ 200) °C Humidity: Max 95 % R.H. |
소재지 |
| IEC 62776:2014 |
Double-capped LED lamps designed to retrofit linear fluorescent lamps - Safety specifications |
Input Voltage: Max 600 V Input Current: Max 20 A Working Voltage: Max peak 100 kV Leakage Current: Max 10 mA Temperature: Max 200 °C Earth Continuity: 12 V, 60 A Electric strength: 5 kV, 100 mA Insulation Resistance: Max 4.5 GΩ Temperature: (-40 ∼ 200) °C Humidity: Max 95 % R.H. Total Luminousflux: Max 250 000 lm Color Rendering: Max 100 Color Temperature: Max 10 000 K Spectral radiance : (300 ~ 1 400) nm Total Luminousflux: Max 1 200 lm |
소재지 |
| K 62471-1:2009 |
램프와 램프장치의 광생물학적 안전성 |
입력전압: 최대 600 V 입력전류: 최대 20 A 분광복사조도 : (200 ~ 2 400) nm 분광복사휘도 : (300 ~ 1 400) nm |
소재지 |
| K 62471-2:2012 |
램프와 램프 시스템의 광 생물학적 안전 -제2부: 광학적 비 레이저 방사선의 안전에 관한 제조 지침 |
입력전압: 최대 600 V 입력전류: 최대 20 A 분광복사조도 : (200 ~ 2 400) nm 분광복사휘도 : (300 ~ 1 400) nm |
소재지 |
| KC 60598-1:2025 |
등기구 제1부: 일반요구사항 및 시험
(제외항목) 4.10.4 보호 저항 장치 12.5 열시험 (C1, C2)
부속서 B, 부속서 C, 부속서 E |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60598-2-1:2022 |
등기구 - 제2-1부: 고정형 등기구 개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60598-2-2:2022 |
등기구 - 제2-2부: 매입형 등기구 개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60598-2-4:2022 |
등기구 제2-4부: 이동형 등기구 개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60598-2-5:2022 |
등기구 제2-5부: 투광등기구-개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 60968:2015 |
안정기 내장형 램프 - 안전요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. 캡치수검출: E26, E27, B22d |
소재지 |
| KC 60968:2022 |
안정기 내장형 램프 - 안전요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. 캡치수검출: E26, E27, B22d |
소재지 |
| KC 61347-1:2022 |
램프구동장치 - 제1부: 일반 및 안전요구사항
(제외항목) 13 권선의 열 내구성 Annex H.4 자기 영향 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. 캡치수검출: E26, E27, B22d |
소재지 |
| KC 61347-2-13:2022 |
램프 구동장치 제2-13부: LED 모듈 구동장치(DC/AC) - 개별 요구사항
(제외항목) 부속서 H.4 자기 영향 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KC 62031:2025 |
일반 조명용 LED 모듈 - 안전 요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. Spectral range: (200 ~ 1800)nm |
소재지 |
| KS C 7651:2022 |
컨버터 내장형 LED 램프 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K Spectral range: (200 ~ 1800)nm 캡 치수 검출 : E26, B22d |
소재지 |
| KS C 7652:2022 |
컨버터 외장형 LED 램프
(제외항목) 6.2.3 치수 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K Spectral range: (200 ~ 1800)nm 캡 치수 검출 : E26, B22d |
소재지 |
| KS C 7653:2024 |
매입형 및 고정형 LED 등기구 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K Spectral range: (200 ~ 1800)nm |
소재지 |
| KS C 7655:2024 |
LED 모듈 전원공급용 컨버터
(제외항목) 5.1 일반 요구사항 및 검사 중 제어단자에 공급되는 제어 신호 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C 7656:2021 |
이동형 LED/OLED 등기구 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K 분광복사조도 : (250 ~ 2 500) nm 분광복사휘도 : (300 ~ 1 400) nm |
소재지 |
| KS C 7657:2021 |
LED 센서 등기구 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K Spectral range: (200 ~ 1800)nm |
소재지 |
| KS C 7658:2024 |
LED 가로등 및 보안등기구 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| KS C 7659:2013 |
문자 간판용 LED 모듈의 안전 및 성능 요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| KS C 7712:2024 |
LED 투광 등기구 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| KS C 7713:2021 |
LED 경관등 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| KS C 7716:2024 |
LED 터널 등기구 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| KS C 7717:2021 |
LED 횡단보도등 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| KS C 7719:2020 |
LED 손전등 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-40 ∼ 200) °C 항습: 최대 95 % R.H. 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| KS C IEC 60598-1:2014 |
등기구 제1부: 일반요구사항 및 시험
(제외항목) 4.10.4 보호 저항 장치 12.5 열시험 (C1, C2)
부속서 B, 부속서 C, 부속서 E |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 60598-2-1:2020 |
등기구 - 제2-1부: 고정형 등기구 개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 60598-2-13:2016 |
등기구 — 제2-13부: 지중매입형 등기구 개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: Max 95 % R.H. |
소재지 |
| KS C IEC 60598-2-2:2011 |
등기구 - 제2-2부: 매입형 등기구 개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 60598-2-3:2014 |
등기구 제2-3부: 가로등기구-개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 60598-2-4:2017 |
등기구-제2-4부:이동형 등기구-개별 요구 사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 60598-2-5:2015 |
등기구 제2-5부: 투광등기구-개별요구사항 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 61347-1:2015 |
램프구동장치 - 제1부: 일반 및 안전요구사항
(제외항목) 13 권선의 열 내구성 부속서 B, 부속서 C, 부속서 D, 부속서 G, 부속서 H.4 자기 영향, 부속서 I |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. 캡치수검출: E26, E27, B22d |
소재지 |
| KS C IEC 61347-2-13:2014 |
램프 구동장치 제2-13부: LED 모듈 구동장치(DC/AC) - 개별 요구사항
(제외항목) Annex H.4 자기 영향 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 62031:2018 |
일반 조명용 LED 모듈 - 안전 규격 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 100 kV 누설전류: 최대 10 mA 온도: 최대 200 °C 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4.5 GΩ 항온: (-30 ∼ 200) °C 항습: 최대 95 % R.H. |
소재지 |
| KS C IEC 62471:2006 |
램프와 램프장치의 광생물학적 안전성 |
입력전압: 최대 600 V 입력전류: 최대 20 A 분광복사조도 : (200 ~ 2 400) nm 분광복사휘도 : (300 ~ 1 400) nm |
소재지 |
| KS C IEC 62471-2:2009 |
램프 및 램프 시스템의 광 생물학적 안전 ― 제2부: 광학적 비 레이저 방사선의 안전에 관한 지침 |
입력전압: 최대 600 V 입력전류: 최대 20 A 분광복사조도 : (200 ~ 2 400) nm 분광복사휘도 : (300 ~ 1 400) nm |
소재지 |
| KS C IEC 62471-5:2015 |
램프 및 램프 시스템의 광 생물학적 안전 — 제5부: 이미지 프로젝터 |
입력전압: 최대 600 V 입력전류: 최대 20 A 분광복사조도 : (200 ~ 2 400) nm 분광복사휘도 : (300 ~ 1 400) nm |
소재지 |
| KS C IEC TR 62778:2014 |
KS C IEC 62471을 응용한 광원 및 등기구의 청색광 위해성 평가 |
입력전압: 최대 600 V 입력전류: 최대 20 A 분광복사휘도 : (300 ~ 1 400) nm |
소재지 |
| 경찰청, LED 교통신호등 표준지침(2022. 4. 27.) |
LED 교통신호등 표준지침 (제외항목) 3.(1) 온도 순환 시험 3.(5) 내진성 시험 4.(10) 임피던스 시험 5.(3) 휘도 균일도 시험 5.(4) 썬팬텀 시험 |
입력전압: 교류 88 V ~ 242 V, 직류 40 V ~ 56 V 온도: (-30 ~ 70) ℃ 내수성: 연직에서 60°, 물의 양 (10 ~ 20) mm/min 진동: 1 G, 33 Hz 절연저항: 직류 500 V, 5 MΩ 내전압: 1 500 V 광도: (0 ~ 11 000 000) cd 색도: 0.009 ~ 0.720 |
소재지 |
| 경찰청, NPA-TSC-2010-R27(2021. 10. 05.) |
교통신호제어기 표준규격서 (제외항목) 7.2.1.5 충격시험 7.2.1.6.5 비파괴 내전압 시험 7.2.1.6.6 전원공급장치(POWER SUPPLY) 출력용량 측정 시험 7.2.2 기능검사 |
입력전압: 190 V ~ 250 V 온도: (-34 ~ 74) ℃ 진동: (5 ~ 33) Hz, 0.5 g 절연저항: 직류 500 V, 10 MΩ 내전압: 1 500 V 뢰임펄스 내전압: 1.2 × 50 ㎲, 5 000 V |
소재지 |
| 경찰청, 가변형 교통안전표지 표준지침(2022. 4. 27.) |
가변형 교통안전표지 표준지침 (제외항목) 10.2.4 충격시험 10.2.8 휘도 및 휘도비 시험 10.2.10 빔 폭(Beam Width) 시험 |
입력전압: 90 V ~ 250 V 온도: (-34 ~ 74) ℃ 내수성: 수직에서 60°, 살수량 (10 ~ 20) mm/min 진동: (5 ~ 33) Hz, 0.5 g 절연저항: 직류 500 V, 10 MΩ 내전압: 1 500 V 조도: (0 ~ 40 000) lx 광도: (0 ~ 11 000 000) cd |
소재지 |
| 경찰청, 경찰-6310-98-0001-차(2022. 8. 1.) |
무인교통단속장비 경찰규격서 (제외항목) 6. 비파괴 내전압 시험 |
입력전압: 교류 190 V ~ 250 V 온도: (-30 ~ 60) ℃ 내수성: 수직에서 60°, 살수량 (10 ~ 20) mm/min 진동: (5 ~ 55) Hz, 0.5 g 절연저항: 직류 500 V, 100 MΩ 내전압: 2 500 V 뢰임펄스 내전압: 1.2 × 50 ㎲, 5 000 V 최대파장: 2 500 nm |
소재지 |
| 경찰청, 바닥형 보행신호등 보조장치 표준지침(2022. 7. 20.) |
바닥형 보행신호등 보조장치 표준지침 |
입력전압: 90 V ~ 250 V 온도: (-34 ~ 74) ℃ 미끄럼 저항: (0 ~ 150) BPN 방수방진: IP68 내수성: 연직에서 60°, 살수량 (10 ~ 20) mm/min 진동: (10 ~ 55) Hz, 9.8 m/s2 충격에너지: 0.7 Nm 압축: 24 mm 정하중 구조: 5 kN 열시험: 200 ℃ 절연저항: 직류 500 V, 4 MΩ 내전압: 1 500 V 뢰 임펄스: 1.2 × 50 ㎲, 5 000 V 광도: (0 ~ 11 000 000) cd 색도: 0.009 ~ 0.720 |
소재지 |
| 경찰청, 보행신호 음성안내 보조장치 표준지침(2022. 1. 14.) |
보행신호 음성안내 보조장치 표준지침 |
입력전압: 190 V ~ 250 V 온도: (-34 ~ 74) ℃ 내수성: 수직에서 60°, 살수량 (10 ~ 20) mm/min 진동: 33 Hz, 9.8 m/s2 절연저항: 직류 500 V, 10 MΩ 내전압: 1 500 V 뢰 임펄스: 1.2 × 50 ㎲, 5 000 V |
소재지 |
| 경찰청, 보행신호 자동연장시스템 표준 규격(2022. 07. 20.) |
보행신호 자동연장시스템 표준 규격 |
입력전압: 90 V ~ 250 V 온도: (-34 ~ 74) ℃ 내수성: 수직에서 60°, 살수량 (10 ~ 20) mm/min 진동: 1 G, 33 Hz, 절연저항: 직류 500 V, 10 MΩ 내전압: 1 500 V 뢰 임펄스: 1.2 × 50 ㎲, 5 000 V |
소재지 |
| 경찰청, 보행신호등 보조장치 표준지침(2022. 2. 4.) |
보행신호등 보조장치 표준지침 (제외항목) 3.(1) 온도순환 시험 5.(2) 휘도분포 시험 |
입력전압: 교류 88 V ~ 242 V, 직류 40 V ~ 50 V 내수성: 수직에서 60°, 살수량 (10 ~ 20) mm/min 진동: 1 G, 33 Hz, 광도: (0 ~ 11 000 000) cd 색도: 0.009 ~ 0.720 |
소재지 |
| 경찰청, 보행자 자동인식 신호기 표준지침(2021. 10. 05.) |
보행자 자동인식 신호기 표준지침 |
입력전압: 190 V ~ 250 V, 온도: (-34 ~ 74) ℃ 내수성: 수직에서 60°, 살수량 (10 ~ 20) mm/min 진동: 1 G, 33 Hz, 절연저항: 직류 500 V, 10 MΩ 내전압: 1 500 V 뢰 임펄스: 1.2 × 50 ㎲, 5 000 V |
소재지 |
| 경찰청, 시각장애인용 음향신호기 규격서(2021. 5. 11.) |
시각장애인용 음향신호기 규격서 (제외항목) 1.라 버튼 내구성 시험 |
입력전압: 90 V ~ 250 V, 온도: (-34 ~ 74) ℃ 내수성: IPX3, 수직에서 60°, 살수량 (10 ~ 20) mm/min 절연저항: 직류 500 V, 5 MΩ 내전압: 1 500 V 뢰 임펄스: 1.2 × 50 ㎲, 5 000 V |
소재지 |
| 경찰청, 조명식 및 발광형 교통안전표지 표준지침(2018. 11. 26.) |
조명식 및 발광형 교통안전표지 표준지침 (제외항목) 10.2.4 충격시험 10.2.9 휘도시험 10.2.10 휘도분포시험 10.2.11 광원의 균일성시험 10.2.13 재귀반사시트 시험 |
입력전압: 90 V ~ 250 V, 온도: (-34 ~ 74) ℃ 내수성: 수직에서 60°, 살수량 (10 ~ 20) mm/min 진동: (5 ~ 33) Hz, 0.5 g 절연저항: 직류 500 V, 10 MΩ 내전압: 1 500 V 색도: 0.009 ~ 0.720 |
소재지 |
| SPS-KIIC 1012-0626:2013 |
가로등용 전자식 자동점멸기·GPS |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1013-0627:2013 |
보안등 전자식 자동점멸기.GPS |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1014-0628:2006 |
보안등용 광전식 자동점멸기 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1015-0629:2006 |
보안등용 복합식 자동점멸기 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1016-0630:2006 |
보안등용 무선식 자동점멸기 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1025-0639:2005 |
가로등 무선식자동점멸기
[제외항목] 7.3.14 정격단시간 내전류시험 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1026-1208:2008 |
도로조명기구
[제외항목] 6.4 반사판 반사율 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-KIIC 1027-1249:2005 |
가로등용 무선식 자동점멸기(양방향)
[제외항목] 7.3.14 정격단시간 내전류시험 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1028-1277:2014 |
경관조명설비
[제외항목] 7.9 내염성 7.14 내열충격시험 7.20 휘도값 7.22 반사판 반사율 7.23 진동 7.28 태양 등기구 밧데리 과충전 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-KIIC 1029-1872:2010 |
보안등용 무선식 양방향 중계기·중계감시 점멸기 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1030-1873:2010 |
보안등용 무선식 양방향 감시 점멸기 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC-1031-2001:2013 |
LED조명엔진 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-KIIC 1032-2042:2014 |
가로등ㆍ보안등용(중앙관제/등주/선로감시)점멸기 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC 1034-7173:2016 |
조명용 제어장치 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C |
소재지 |
| SPS-KIIC-1035-7178:2017 |
콤팩트형 LED램프 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-KIIC-1036-7179:2017 |
스마트 안심 LED 보안등 기구
[제외항목] 7.9 영상기록장치 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-C KIIC-1040-7566:2023 |
스포츠 경기장용 LED 등기구 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-LEDLIC-1870:2009 |
LED 방폭등기구-성능 요구 사항
[제외항목] 6.4 반사판 반사율 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-C KPSIC 0001-7337:2019 |
주차장용 차량번호판 인식장치 |
입력전압: 최대 250 V 온도 : (-40 ~ 150) °C |
소재지 |
| SPS-C KPSIC 0002-7403:2020 |
무인 주차요금 정산기 |
입력전압: 최대 250 V 온도 : (-40 ~ 150) °C |
소재지 |
| SPS-C KPSIC 0003-7543:2022 |
주차장용 차량 차단기 |
입력전압: 최대 250 V 온도 : (-40 ~ 150) °C |
소재지 |
| SPS-LEDLEC-1869:2009 |
LED 손전등-성능 요구 사항 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-LEDLIC-1871:2009 |
LED 공조용 등기구 - 성능 요구 사항 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-LEDLIC-1848:2009 |
LED수중등기구 - 안전 및 성능요구사항 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| SPS-LEDLIC-1849:2009 |
LED 휴대 전등 - 성능 요구 사항
[제외항목] 6.2 스위치 기구 시험 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 전광선속: 최대 250 000 lm 연색지수: 최대 100 상관색온도: 최대 10 000 K |
소재지 |
| Revision 02(2025.8.22) |
교통안전시설 등 시험·검사 통합지침
[제외항목] 3.3 세부 기능검사 4.4.1.1 LED 교통신호등 4.4.1.2 보행신호등 보조장치 4.4.2 버튼 4.5.7 전자파 적합성 시험 4.5.10 임피던스 시험 4.6.2 광도 분포 시험 4.6.3.1 교통신호등 및 보행신호등 보조장치 4.7 재질 시험 |
입력전압: 최대 300 V 입력전류: 최대 20 A 온도: (-40 ~ 150) °C 챔버사용온도: (-34 ~ 74) °C 절연저항: DC 500 V, 10 MΩ 내전압시험: 최대 1.5 kV, 10 mA |
소재지 |
| ▶ 의료기기 |
| EN 60601-1:2006+A1:2013+A2:2021 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance [Exception] 8.8.4.2 Resistance to environmental stress - Requirements of insulating material for rubber 8.9.1.7 Material groups classification 9.5.2 Cathode ray tubes 10.3 Microwave radiation 10.4 Lasers 11.2 Fire prevention 11.4 ME EQUIPMENT and ME SYSTEMS intended for use with flammable anaesthetics 11.6.7 Sterilization of ME EQUIPMENT and ME SYSTEMS 15.4.2 Temperature and overload control devices 15.4.3.4 Lithium batteries Annex A 10.4 Laser Annex G(normative) Protection against HAZARDS of ignition of flammable anaesthetic mixtures Annex L(normative) Insulated winding wires for use without interleaved insulation |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input current(AC single phase): Max. 20 A Input current:(AC three phase): Max. 500 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| EN 60601-1-11:2015+A1:2021 |
Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment [Exception] 4.2.3 Environmental operation conditions 10.1.2 Requirements for Mechanical strength for NON-TRANSIT-OPERABLE ME EQUIPMENT / Shock and Vibration 10.1.3 Requirements for Mechanical strength for TRANSIT-OPERABLE ME EQUIPMENT / Shock and Vibration 12 Additional requirements for electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS / Emissions classification 13 Additional requirement for generation of ALARM SIGNALS / Alarm signal |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: (0 ~ 200) ℃ Temperature & Humidity: (-45 ~ 70) ℃, Max. 93 % R.H. |
소재지-2 |
| EN 60601-1-12:2014+A1:2020 |
Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment [Exception] 4.2.2 Environmental operation conditions 10.1.2 Requirements for mechanical strength for FIXED or PERMANENTLY INSTALLED ME EQUIPMENT intended for use in a road ambulance 10.1.3 Requirements for mechanical strength for TRANSPORTABLE ME EQUIPMENT 10.1.4 Requirements for mechanical strength for ME EQUIPMENT intended for airborne use 11 Additional requirements for electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: (0 ~ 200) ℃ Temperature & Humidity: (-45 ~ 70) ℃, Max. 93 % R.H. |
소재지-2 |
| EN 60601-1-3:2008+A1:2013+A2:2021 |
Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| EN 60601-1-6:2010+A1:2015+A2:2021 |
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability |
- |
소재지-2 |
| EN 60601-1-8:2007+A1:2013+A2:2021 |
Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems [Exception] 6.3.3.1 Characteristics of the pulse of auditory alarm signals 6.3.3.2 Volume of auditory alarm signals and information signals |
Illuminance: (100 ~ 1 500) lx Frequency: (120 Hz ~ 16 kHz) Sound level: (30 ~ 130) dBA |
소재지-2 |
| EN 60601-2-10:2015+A1:2016 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators [Exception] 202 Electromagnetic disturbances – requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Output current: 150 mA Output voltage: 150 V |
소재지-2 |
| EN 60601-2-18:2015 |
Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment [Exception] 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| EN 60601-2-25:2015 |
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz |
소재지-2 |
| EN 60601-2-27:2014 |
Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests 208.6.3.3 Auditory ALARM SIGNALS |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz |
소재지-2 |
| EN 60601-2-37:2008+A1:2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202.6 ELECTROMAGNETIC COMPATIBILITY |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| EN 60601-2-43:2010+A1:2018 |
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| EN 60601-2-43:2010+A1:2018+A2:2020 |
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| EN 60601-2-5:2015 |
Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment [Exception] 201.10.102 Unwanted ultrasound radiation 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: 50 ℃ |
소재지-2 |
| EN 60601-2-54:2009+A1:2015 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| EN 60601-2-54:2009+A1:2015+A2:2019 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| EN 60601-2-57:2011 |
Medical electrical equipment - Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use [Exception] 201.10.103 Output uniformity 201.12.4.2 Indication of parameters relevant to safety |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Force: (10 ~ 52) N |
소재지-2 |
| EN 60601-2-62:2015 |
Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment [Exception] 201.10 Protection against unwanted and excessive radiation HAZARDS 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| EN IEC 60601-2-2:2018 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories [Exception] 201.15.101.5 NE thermal performance 201.15.101.6 NE contact impedance 201.15.11.7 NE adhesion 202 ELECTROMAGNETIC DISTURBANCES – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz HF leakage current: (0 ~ 150) mA HF output: (0 ~ 400) W Resistance: Max. 2 000 Ω Angle: 90° (45° on each side of the vertical) |
소재지-2 |
| EN IEC 60601-2-22:2020 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous output 201.13.2 SINGLE FAULT CONDITIONS |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Force: (10 ~ 50) N |
소재지-2 |
| EN IEC 60601-2-28:2019 |
Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| EN IEC 60601-2-43:2023 |
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| EN IEC 80601-2-60:2020 |
Medical electrical equipment - Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment [Exception] 201.10.4 Lasers and light-emitting diodes (LED) |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| EN IEC 80601-2-77:2021 |
Medical electrical equipment - Part 2-77: Particular requirements for the basic safety and essential performance of robotically assisted surgical equipment [Exception] 202 ELECTROMAGNETIC DISTURBANCES – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| EN IEC 80601-2-78:2020 |
Medical electrical equipment - Part 2-78: Particular requirements for basic safety and essential performance of medical robots for rehabilitation, assessment, compensation or alleviation [Exception] 202 ELECTROMAGNETIC DISTURBANCES – Requirements and tests 210 Process requirements for the development of PHYSIOLOGIC CLOSED-LOOP CONTROLLERS 211.10.1.1 General requirements for mechanical strength |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| IEC 60601-1:2005 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance [Exception] 8.8.4.2 Resistance to environmental stress - Requirements of insulating material for rubber 8.9.1.7 Material groups classification 9.5.2 Cathode ray tubes 10.3 Microwave radiation 10.4 Lasers 11.2 Fire prevention 11.4 ME EQUIPMENT and ME SYSTEMS intended for use with flammable anaesthetics 11.6.7 Sterilization of ME EQUIPMENT and ME SYSTEMS 15.4.2 Temperature and overload control devices 15.4.3.4 Lithium batteries Annex A 10.4 Laser Annex G(normative) Protection against HAZARDS of ignition of flammable anaesthetic mixtures Annex L(normative) Insulated winding wires for use without interleaved insulation |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input current(AC single phase): Max. 20 A Input current:(AC three phase): Max. 500 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| IEC 60601-1:2005 +A1:2012 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance [Exception] 8.8.4.2 Resistance to environmental stress - Requirements of insulating material for rubber 8.9.1.7 Material groups classification 9.5.2 Cathode ray tubes 10.3 Microwave radiation 10.4 Lasers 11.2 Fire prevention 11.4 ME EQUIPMENT and ME SYSTEMS intended for use with flammable anaesthetics 11.6.7 Sterilization of ME EQUIPMENT and ME SYSTEMS 15.4.2 Temperature and overload control devices 15.4.3.4 Lithium batteries Annex A 10.4 Laser Annex G(normative) Protection against HAZARDS of ignition of flammable anaesthetic mixtures Annex L(normative) Insulated winding wires for use without interleaved insulation |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input current(AC single phase): Max. 20 A Input current:(AC three phase): Max. 500 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| IEC 60601-1:2005+A1:2012+A2:2020 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance [Exception] 8.8.4.2 Resistance to environmental stress - Requirements of insulating material for rubber 8.9.1.7 Material groups classification 9.5.2 Cathode ray tubes 10.3 Microwave radiation 10.4 Lasers 11.2 Fire prevention 11.4 ME EQUIPMENT and ME SYSTEMS intended for use with flammable anaesthetics 11.6.7 Sterilization of ME EQUIPMENT and ME SYSTEMS 15.4.2 Temperature and overload control devices 15.4.3.4 Lithium batteries Annex A 10.4 Laser Annex G(normative) Protection against HAZARDS of ignition of flammable anaesthetic mixtures Annex L(normative) Insulated winding wires for use without interleaved insulation |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input current(AC single phase): Max. 20 A Input current:(AC three phase): Max. 500 A Input Frequency: (50/60) Hz Leakage current: Max. 500 mA Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Earth continuity: 6 V, 60 A Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| IEC 60601-1-11:2015 |
Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment [Exception] 4.2.3 Environmental operation conditions 10.1.2 Requirements for Mechanical strength for NON-TRANSIT-OPERABLE ME EQUIPMENT / Shock and Vibration 10.1.3 Requirements for Mechanical strength for TRANSIT-OPERABLE ME EQUIPMENT / Shock and Vibration 12 Additional requirements for electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS / Emissions classification 13 Additional requirement for generation of ALARM SIGNALS / Alarm signal |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: (0 ~ 200) ℃ Temperature & Humidity: (-45 ~ 70) ℃, Max. 93 % R.H. |
소재지-2 |
| IEC 60601-1-11:2015+A1:2020 |
Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment [Exception] 4.2.3 Environmental operation conditions 10.1.2 Requirements for Mechanical strength for NON-TRANSIT-OPERABLE ME EQUIPMENT / Shock and Vibration 10.1.3 Requirements for Mechanical strength for TRANSIT-OPERABLE ME EQUIPMENT / Shock and Vibration 12 Additional requirements for electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS / Emissions classification 13 Additional requirement for generation of ALARM SIGNALS / Alarm signal |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: (0 ~ 200) ℃ Temperature & Humidity: (-45 ~ 70) ℃, Max. 93 % R.H. |
소재지-2 |
| IEC 60601-1-12:2014 |
Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment [Exception] 4.2.2 Environmental operation conditions 10.1.2 Requirements for mechanical strength for FIXED or PERMANENTLY INSTALLED ME EQUIPMENT intended for use in a road ambulance 10.1.3 Requirements for mechanical strength for TRANSPORTABLE ME EQUIPMENT 10.1.4 Requirements for mechanical strength for ME EQUIPMENT intended for airborne use 11 Additional requirements for electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: (0 ~ 200) ℃ Temperature & Humidity: (-45 ~ 70) ℃, Max. 93 % R.H. |
소재지-2 |
| IEC 60601-1-12:2014+A1:2020 |
Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment [Exception] 4.2 Environmental conditions for ME EQUIPMENT 10.1.2 Requirements for mechanical strength for FIXED or PERMANENTLY INSTALLED ME EQUIPMENT intended for use in a road ambulance 10.1.3 Requirements for mechanical strength for TRANSPORTABLE ME EQUIPMENT 10.1.4 Requirements for mechanical strength for ME EQUIPMENT intended for airborne use 11 Additional requirements for electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: (0 ~ 200) ℃ Temperature & Humidity: (-45 ~ 70) ℃, Max. 93 % R.H. |
소재지-2 |
| IEC 60601-1-3:2008 |
Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-1-3:2008+A1:2013 |
Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-1-3:2008+A1:2013+A2:2021 |
Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-1-6:2010 |
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability |
- |
소재지-2 |
| IEC 60601-1-6:2010+A1:2013 |
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability |
- |
소재지-2 |
| IEC 60601-1-6:2010+A1:2013+A2:2020 |
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability |
- |
소재지-2 |
| IEC 60601-1-8:2006 |
Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems [Exception] 6.3.3.1 Characteristics of the pulse of auditory alarm signals 6.3.3.2 Volume of auditory alarm signals and information signals |
Illuminance: (100 ~ 1 500) lx Frequency: (120 Hz ~ 16 kHz) Sound level: (30 ~ 130) dBA |
소재지-2 |
| IEC 60601-1-8:2006+A1:2012 |
Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems [Exception] 6.3.3.1 Characteristics of the pulse of auditory alarm signals 6.3.3.2 Volume of auditory alarm signals and information signals |
Illuminance: (100 ~ 1 500) lx Frequency: (120 Hz ~ 16 kHz) Sound level: (30 ~ 130) dBA |
소재지-2 |
| IEC 60601-1-8:2006+A1:2012+A2:2020 |
Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems [Exception] 6.3.3.1 Characteristics of the pulse of auditory alarm signals 6.3.3.2 Volume of auditory alarm signals and information signals |
Illuminance: (100 ~ 1 500) lx Frequency: (120 Hz ~ 16 kHz) Sound level: (30 ~ 130) dBA |
소재지-2 |
| IEC 60601-2-10:2012 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators [Exception] 202 Electromagnetic disturbances – requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Output current: 150 mA Output voltage: 150 V |
소재지-2 |
| IEC 60601-2-10:2012+A1:2016 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators [Exception] 202 Electromagnetic disturbances – requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Output current: 150 mA Output voltage: 150 V |
소재지-2 |
| IEC 60601-2-10:2012+A1:2016+A2:2023 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators [Exception] 202 Electromagnetic disturbances – requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Output current: 150 mA Output voltage: 150 V |
소재지-2 |
| IEC 60601-2-18:2009 |
Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment [Exception] 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| IEC 60601-2-2:2017 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories [Exception] 201.15.101.5 NE thermal performance 201.15.101.6 NE contact impedance 201.15.11.7 NE adhesion 202 ELECTROMAGNETIC DISTURBANCES – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz HF leakage current: (0 ~ 150) mA HF output: (0 ~ 400) W Resistance: Max. 2 000 Ω Angle: 90° (45° on each side of the vertical) |
소재지-2 |
| IEC 60601-2-22:2007 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous output 201.13.2 SINGLE FAULT CONDITIONS |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Force: (10 ~ 50) N |
소재지-2 |
| IEC 60601-2-22:2007+A1:2012 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous output 201.13.2 SINGLE FAULT CONDITIONS |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Force: (10 ~ 50) N |
소재지-2 |
| IEC 60601-2-22:2019 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous output 201.13.2 SINGLE FAULT CONDITIONS |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Force: (10 ~ 50) N |
소재지-2 |
| IEC 60601-2-25:2011 |
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz |
소재지-2 |
| IEC 60601-2-27:2011 |
Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests 208.6.3.3 Auditory ALARM SIGNALS |
Input voltage(AC single phase): Max. 300 V |
소재지-2 |
| IEC 60601-2-28:2017 |
Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
Input voltage(AC single phase): Max. 300 V Input voltage(AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-2-37:2007 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202.6 ELECTROMAGNETIC COMPATIBILITY |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| IEC 60601-2-37:2007+A1:2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment [Exception] 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202.6 ELECTROMAGNETIC COMPATIBILITY |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| IEC 60601-2-43:2010+A1:2017 |
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-2-43:2010+A1:2017+A2:2019 |
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-2-43:2022 |
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-2-5:2009 |
Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment [Exception] 201.10.102 Unwanted ultrasound radiation 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Temperature: 50 ℃ |
소재지-2 |
| IEC 60601-2-54:2009+A1:2015 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-2-54:2009+A1:2015+A2:2018 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-2-54:2022 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy [Exception] 202 Electromagnetic disturbances – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz X-ray dose: 1 nGy ~ 9 999 Gy Distance: 5.5 m |
소재지-2 |
| IEC 60601-2-57:2011 |
Medical electrical equipment - Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use [Exception] 201.10.103 Output uniformity 201.12.4.2 Indication of parameters relevant to safety |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Dielectric strength test: 10 kV Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Force: (10 ~ 50) N |
소재지-2 |
| IEC 60601-2-62:2013 |
Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment [Exception] 201.10 Protection against unwanted and excessive radiation HAZARDS 201.12 Accuracy of controls and instruments and protection against hazardous outputs 202 Electromagnetic compatibility – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| IEC 80601-2-60:2012 |
Medical electrical equipment - Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment [Exception] 201.10.4 Lasers and light-emitting diodes (LED) |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| IEC 80601-2-60:2019 |
Medical electrical equipment - Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment [Exception] 201.10.4 Lasers and light-emitting diodes (LED) |
Input voltage(AC single phase): Max. 300 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ |
소재지-2 |
| IEC 80601-2-77:2019 |
Medical electrical equipment - Part 2-77: Particular requirements for the basic safety and essential performance of robotically assisted surgical equipment [Exception] 202 ELECTROMAGNETIC DISTURBANCES – Requirements and tests |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| IEC 80601-2-78:2019 |
Medical electrical equipment - Part 2-78: Particular requirements for basic safety and essential performance of medical robots for rehabilitation, assessment, compensation or alleviation [Exception] 202 ELECTROMAGNETIC DISTURBANCES – Requirements and tests 210 Process requirements for the development of PHYSIOLOGIC CLOSED-LOOP CONTROLLERS 211.10.1.1 General requirements for mechanical strength |
Input voltage(AC single phase): Max. 300 V Input voltage (AC three phase): Max. 500 V Input Frequency: (50/60) Hz Humidity: Max. 95 % R.H. Temperature: Max. 200 ℃ Length: Max. 3 000 mm |
소재지-2 |
| ▶ 전자기적합성 |
| AS 61000.6.4:2020 |
Electromagnetic compatibility (EMC) -Part 6.4 : Generic standards -Emission standard for industrial environments (IEC 61000-6-4:2018 (ED 3.0) MOD) |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS CISPR 11:2017 |
Industrial, Scientific and medical (ISM) radio frequency equipment-Electromagnetic disturbance characteristics -Limits and methods of measurement (CISPR 11:2015+AMD1:2016 (ED.6.1)) |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS CISPR 11:2017+A1:2020 |
Industrial, Scientific and medical (ISM) radio frequency equipment-Electromagnetic disturbance characteristics -Limits and methods of measurement (CISPR 11:2015+AMD1:2016 (ED.6.1)) |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS CISPR 15:2017 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15:2013+AMD1:2015 (ED.8.1)MOD)
[Exception] 7. Method of insertion loss measurement |
RE : 9 kHz ~ 300 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS 61000.6.3:2012 |
Electromagnetic compatibility (EMC) -Part 6.3 : Generic standards -Emission standard for residential, commercial and light -industrial environments |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS 61000.6.3:2021 |
Electromagnetic compatibility (EMC) -Part 6.3 : Generic standards -Emission standard for residential, commercial and light -industrial environments (IEC 61000-6-3:2020 (ED 3.0) MOD) |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS 61000.6.4:2012 |
Electromagnetic compatibility (EMC) -Part 6.4 : Generic standards -Emission standard for industrial environments |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS CISPR 11:2011 |
Industrial, Scientific and medical (ISM) radio frequency equipment-Electromagnetic disturbance characteristics -Limits and methods of measurement |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS CISPR 14-1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus, Part 1: Emission (CISPR 14-1:2020 (ED 7.0) MOD) |
CE : 9 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 9 kHz ~ 6 GHz |
소재지-1 |
| AS/NZS CISPR 15:2011 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15, Ed.7.2. (2009) MOD)
[Exception] 7. Method of insertion loss measurement |
RE : 9 kHz ~ 300 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS CISPR 15:2025 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15:2018 (ED.9.1) MOD) |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS CISPR 32:2013 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| AS/NZS CISPR 32:2015+A1:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 11:2015+AMD1:2016+AMD2:2019 CSV |
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement
(Exception) 6.2.2 Group 2. 30 meter measurement |
RE : 9 kHz ~ 18 GHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 13:2009+AMD1:2015 |
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement |
RE : 30 MHz ~ 1 GHz
DISTURBANCE VOLTAGE : 9 kHz ~ 2.15 GHz Radiated Power : 0.9 GHz ~ 18 GHz CE : 150 kHz ~ 30 MHz |
소재지-1 |
| CISPR 14-1:2005+AMD1:2008+AMD2:2011 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Disturbance Power : 30 MHz ~ 300 MHz RE: 30 MHz ~ 1 GHz CE : 150 kHz ~ 30 MHz |
소재지-1 |
| CISPR 14-1:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Disturbance Power : 30 MHz ~ 300 MHz RE: 9 kHz ~ 6 GHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 14-2:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| CISPR 15:2013 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) 4.5.3 Frequency range 30 MHz to 1 GHz 3 m, 4 m Loop antenna test method 7. Method of insertion loss measurement |
RE : 9 kHz ~ 30 MHz CE : 9 kHz ~ 30 MHz |
소재지 |
| CISPR 15:2013 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) 7. Method of insertion loss measurement |
RE : 9 kHz ~ 300 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 15:2018 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) 4.5.3 Frequency range 30 MHz to 1 GHz 3 m, 4 m Loop antenna test method |
RE : 9 kHz ~ 30 MHz CE : 9 kHz ~ 30 MHz |
소재지 |
| CISPR 15:2018 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 16-1-3:2004 |
Specification for radio disturbance and immunity measuring apparatus and methods -Part 1-3: Radio disturbance and immunity measuring apparatus -Ancillary equipment Disturbance power |
Absorbing Clamp : 30 MHz ~ 1 000 MHz |
소재지-1 |
| CISPR 16-1-4:2010 |
Specification for radio disturbance and immunity measuring apparatus and methods – Part 1-4: Radio disturbance and immunity measuring apparatus –Antennas and test sites for radiated disturbance measurements |
RE: 30 MHz ~ 18 GHz |
소재지-1 |
| CISPR 16-2-1:2014 |
Specification for radio disturbance and immunity measuring apparatus and methods -Part 2-1 : Methods of measurement of disturbances and immunity -Conducted disturbance measurements |
CE : 0.009 MHz ~ 30 MHz |
소재지-1 |
| CISPR 16-2-2:2010 |
Specification for radio disturbance and immunity measuring apparatus and methods -Part 2-2 : Methods of measurement of disturbances and immunity -Measurement of disturbance power |
RFI : 30 MHz ~ 1 000 MHz |
소재지-1 |
| CISPR 16-2-3:2010+AMD1:2010 |
Specification for radio disturbance and immunity measuring apparatus and methods -Part 2-3 : Methods of measurement of disturbances and immunity -Radiated disturbance measurements |
RE : 0.009 MHz ~ 18 GHz |
소재지-1 |
| CISPR 16-2-4:2003 |
Specification for radio disturbance and immunity measuring apparatus and methods -Part 2-4 :Methods of measurement of disturbances and immunity -Immunity measurements |
CS : 0.15 MHz ~ 230 MHz |
소재지-1 |
| CISPR 16-2-5:2008 |
Specification for radio disturbance and immunity measuring apparatus and methods -Part 2-5 :In situ measurements of disturbing emissions produced by physically large equipment |
RE : 9 kHz ~ 18 GHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 24:2010 |
Information technology equipment - Immunity characteristics - Limits and methods of measurement |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| CISPR 32:2012 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| CISPR 32:2015+A1:2019 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE:30 ㎒ ∼ 18 ㎓, CE:150 ㎑ ∼ 30 ㎒ |
소재지-1 |
| CISPR 35:2016 |
Electromagnetic compatibility of multimedia equipment – Immunity requirements |
ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 1 000 ㎒ RS(spot test): 3 V/m, (1 800, 2 600, 3 500, 5 000) ㎒ EFT/B: ±1 ㎸ Surge: ±4 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 1 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| Draft ETSI EN 300 386 V3.0.0 |
Electromagnetic compatibility and Radio Spectrum Matters (ERM) : Telecommunication network equipment Electromagnetic compatibility (EMC) requirements |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz H/F : 16 A ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~80 MHz V-DIP : (0 ~ 100) % |
소재지-1 |
| Draft ETSI EN 301 489-13 V2.0.0 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 13: Specific conditions for Citizens' Band (CB) radio and ancillary equipment (speech and non-speech) |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| EN 50130-4:2011/A1:2014 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 55011:2016/A1:2017 |
Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement
(Exception) 6.2.2 Group 2. 30 meter measurement |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| EN 55011:2016/A11:2020 |
Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement
(Exception) 6.2.2 Group 2. 30 meter measurement |
CE: 9 kHz ~ 30 MHz RE: 9 kHz ~ 18 GHz |
소재지-1 |
| EN 55011:2016/A2:2021 |
Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement
(Exception) 6.2.2 Group 2. 30 meter measurement |
CE: 9 kHz ~ 30 MHz RE: 9 kHz ~ 18 GHz |
소재지-1 |
| EN 55013:2013+A1:2016 |
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement |
RE : 30 MHz ~ 1 GHz DISTURBANCE VOLTAGE : 9 kHz ~ 2.15 GHz Radiated Power : 0.9 GHz ~ 18 GHz CE : 150 kHz ~ 30 MHz |
소재지-1 |
| EN 55014-1:2017+A11:2020 |
Electromagnetic compatibitliy - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE : 9 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 9 kHz ~ 1 GHz |
소재지-1 |
| EN 55014-1:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 1: Emission |
Disturbance Power : 30 MHz ~ 300 MHz RE: 9 kHz ~ 6 GHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| EN 55024:2010/A1:2015 |
Information technology equipment - Immunity characteristics - Limits and methods of measurement |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 55032:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| EN 55032:2015+A1:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| EN 55032:2015+A11:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| EN 55035:2017 |
Electromagnetic compatibility of multimedia equipment – Immunity requirements |
ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 1 000 ㎒ RS(spot test): 3 V/m, (1 800, 2 600, 3 500, 5 000) ㎒ EFT/B: ±1 ㎸ Surge: ±4 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 1 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| EN 55035:2017+A11:2020 |
Electromagnetic compatibility of multimedia equipment – Immunity requirements |
ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 1 000 ㎒ RS(spot test): 3 V/m, (1 800, 2 600, 3 500, 5 000) ㎒ EFT/B: ±1 ㎸ Surge: ±4 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 1 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| EN 55103-1:2009/A1:2012 |
Electromagnetic compatibility - Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use -- Part 1: Emissions |
RE : 30 MHz ~ 18 GHz CE : 150 kHz ~ 30 MHz |
소재지-1 |
| EN 55103-2:2009 |
Electromagnetic compatibility - Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use -- Part 2:Immunity |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 60601-1-2:2015 |
Medical electrical equipment -- Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE: 0.15 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: CD ±8 ㎸ AD: ±15 ㎸ RS: 10 V/m, 80 ㎒ ~ 2 700 ㎒ RS(Proximity fields): 9 V/m ~ 28 V/m, 385 ㎒~5 785 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 6 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| EN 60601-1-2:2015+A1:2021 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2:2014/A1:2020) |
CE: 0.15 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: CD ±8 ㎸ AD: ±15 ㎸ RS: 10 V/m, 80 ㎒ ~ 2 700 ㎒ RS(Proximity fields): 9 V/m ~ 28 V/m, 385 ㎒~5 785 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 6 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| EN 60601-2-10:2015 |
Medical electrical equipment – Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS 202 Electromagnetic compatibility–Requireme nts and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 2 500 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| EN 60601-2-10:2015+A1:2016 |
Medical electrical equipment – Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS 202 Electromagnetic compatibility–Requireme nts and tests |
CE: 0.15 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: CD ±8 ㎸ AD: ±15 ㎸ RS: 10 V/m, 80 ㎒ ~ 2 700 ㎒ RS(Proximity fields): 9 V/m ~ 28 V/m, 385 ㎒ ~ 5 785 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 6 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| EN 60601-2-18: 2015 |
Medical electrical equipment – Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS 202 Electromagnetic compatibility – Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 2 500 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| EN 61000-3-3:2013+A1:2019 |
Electromagnetic compatibility (EMC) — Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
16 A |
소재지-1 |
| EN 61000-3-3:2013+A1:2019 |
Electromagnetic compatibility (EMC) — Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
16 A |
소재지 |
| EN 61000-3-3:2013+A1:2019+A2:2021 |
Electromagnetic compatibility (EMC) — Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
16 A |
소재지-1 |
| EN 61000-4-11:2004/A1:2017 |
Electromagnetic compatability (EMC) — Part4-11: Testing and measurement techniques — Voltage dips, short interruptions and voltage variations immunity tests |
(0 ~ 100) % |
소재지-1 |
| EN 61000-4-11:2004/A1:2017 |
Electromagnetic compatability (EMC) — Part4-11: Testing and measurement techniques — Voltage dips, short interruptions and voltage variations immunity tests |
(0 ~ 100) % |
소재지 |
| EN 61000-4-2:2009 |
Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement techniques — Electrostatic discharge immunity test |
±30 kV |
소재지-1 |
| EN 61000-4-2:2009 |
Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement techniques — Electrostatic discharge immunity test |
±30 kV |
소재지 |
| EN 61000-4-3:2006+A2:2010 |
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
10 V/m |
소재지-1 |
| EN 61000-4-3:2006+A2:2010 |
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
10 V/m |
소재지 |
| EN 61000-4-34:2007/A1:2009 |
Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase |
Voltage: Max. 3 Φ, 400 V Current: Max. 32 A V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61000-4-4:2012 |
Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test |
±5.5 kV |
소재지-1 |
| EN 61000-4-4:2012 |
Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test |
±4 kV |
소재지 |
| EN 61000-4-5:2014/A1:2017 |
Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques — Surge immunity test |
±7.0 kV |
소재지-1 |
| EN 61000-4-5:2014/A1:2017 |
Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques — Surge immunity test |
±6 kV |
소재지 |
| EN 61000-4-6:2014/AC:2015 |
Electromagnetic compatibility (EMC) — Part 4-6:Testing and measurement techniques — Immunity to conducted disturbances, induced by radio-frequency fields |
10 V |
소재지-1 |
| EN 61000-4-6:2014/AC:2015 |
Electromagnetic compatibility (EMC) — Part 4-6:Testing and measurement techniques — Immunity to conducted disturbances, induced by radio-frequency fields |
10 V |
소재지 |
| EN 61000-4-8:2010 |
Electromagnetic compatibility (EMC) — Part 4-8: Testing and measurement techniques — Power frequency magnetic field immunity test |
30 A/m |
소재지-1 |
| EN 61000-4-8:2010 |
Electromagnetic compatibility (EMC) — Part 4-8: Testing and measurement techniques — Power frequency magnetic field immunity test |
30 A/m |
소재지 |
| EN 61000-6-3:2007+A1:2011 |
Electromagnetic compatibility (EMC) — Part 6-3: Generic standards — Emission standard for residential, commercial and light-industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| EN 61000-6-4:2007+A1:2011 |
Electromagnetic compatibility (EMC) — Part 6-4: Generic standards — Emission standard for industrial environments
(Exception) 3 phase equipment |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| EN 61204-3:2000 |
Low voltage power supplies, d.c. output -- Part 3: Electromagnetic compatibility |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61326-1:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61326-2-1:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61326-2-2:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low- voltage distribution systems |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61326-2-3:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61326-2-4:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61326-2-5:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with interfaces according to IEC 61784-1, CP 3/2 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61326-2-6:2013 |
Electrical equipment for measurement, control and laboratory use EMC requirements Part 2-6: Particular requirements In vitro diagnostic (IVD) medical equipment |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61547:2009 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 61547:2009 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD : ±8 kV RS: 80 MHz ~ 1 GHz 3 V/m EFT : ±1 kV SURGE : ±2 kV CS: 150 kHz ~ 80 MHz 3 V V-DIP: max 100 % |
소재지 |
| EN 62040-2:2006 |
Uninterruptible power system (UPS) Part 2 : Electromagnetic Compatibility (EMC) requirements |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN 62493:2015 |
Assessment of Lighting Equipment related to Human Exposure to Electromagnetic Fields |
EMF : 20 kHz ~ 10 MHz |
소재지-1 |
| EN 62493:2015 |
Assessment of Lighting Equipment related to Human Exposure to Electromagnetic Fields |
EMF : 20 kHz ~ 10 MHz |
소재지 |
| EN IEC 55014-1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 1: Emission |
Disturbance Power : 30 MHz ~ 300 MHz RE: 9 kHz ~ 6 GHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| EN IEC 55014-2:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~ 230 MHz V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 55015:2019 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| EN IEC 55015:2019 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) 4.5.3 Frequency range 30 MHz to 1 GHz 3 m, 4 m Loop antenna test method |
RE : 9 kHz ~ 30 MHz CE : 9 kHz ~ 30 MHz |
소재지 |
| EN IEC 55015:2019/A11:2020 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| EN IEC 55015:2019/A11:2020 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) 4.5.3 Frequency range 30 MHz to 1 GHz 3 m, 4 m Loop antenna test method |
RE : 9 kHz ~ 30 MHz CE : 9 kHz ~ 30 MHz |
소재지 |
| EN IEC 61000-3-2:2019 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) |
16 A |
소재지-1 |
| EN IEC 61000-3-2:2019 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase)
(Exception) 3 phase equipment |
16 A |
소재지 |
| EN IEC 61000-3-2:2019+A1:2021+A2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) |
16 A |
소재지-1 |
| EN IEC 61000-6-1:2019 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V ,150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61000-6-2:2019 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V ,150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61000-6-3:2021 |
Electromagnetic compatibility (EMC) — Part 6-3: Generic standards — Emission standard for equipment in residential environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| EN IEC 61000-6-4:2019 |
Electromagnetic compatibility (EMC) — Part 6-4: Generic standards — Emission standard for industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| EN IEC 61204-3:2018 |
Low voltage power supplies, d.c. output - Part 3: Electromagnetic compatibility (EMC) (IEC 61204-3:2016) |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz DP: 30 MHz ~ 300 MHz H/F : 16 A ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61326-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements (IEC 61326-1:2020) |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61326-2-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications (IEC 61326-2-1:2020) |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61326-2-2:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low- voltage distribution systems (IEC 61326-2-2:2020) |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61326-2-3:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning (IEC 61326-2-3:2020) |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61326-2-4:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 (IEC 61326-2-4:2020) |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61326-2-5:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784-1(IEC 61326-2-5:2020) |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61326-2-6:2021 |
Electrical equipment for measurement, control and laboratory use EMC requirements Part 2-6: Particular requirements In vitro diagnostic (IVD) medical equipment |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| EN IEC 61547:2023 |
Equipment for general lighting purposes - EMC immunity requirements (IEC 61547:2020) |
ESD: ±15 ㎸ RS: 3 V/m, 80 ㎒ ~ 1 000 ㎒ EFT/B: ±1 ㎸ Surge: ±4 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ V-DIP: (0 ~ 100) % |
소재지-1 |
| EN IEC 62040-2:2018 |
Uninterruptible power system (UPS) Part 2 : Electromagnetic Compatibility (EMC) requirements (IEC 62040-2:2016)
[Exception] Immunity to Low-frequency signals IEC 61000-2-2 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 GHz H/F: 16 A ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 1 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ES-0000-0002:2014 |
한전표준규격 - 전자기적합성 시험 일반
4.5 전원장치 및 전기자동차 충전시스템
[제외항목] IEC 61000-4-18 감쇄 진동서지 내성시험 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 6 GHz ESD : ±15 kV RS : 10 V/m, 80 MHz ~ 1 GHz EFT : ±4 kV SURGE : ±6 kV CS : 10 V, 150 kHz ~ 80 MHz V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 300 386 V1.6.1 |
Electromagnetic compatibility and Radio Spectrum Matters (ERM) : Telecommunication network equipment Electromagnetic compatibility (EMC) requirements |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 301 489-1 V2.2.3 |
EMC standard for radio equipment and services; Part 1: Common technical requirements: Harmonised Standard for ElectroMagnetic Compatibility
[Exception] 9.6 Transients and surges in the vehicular environment |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 301 489-13 V1.2.1 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 13: Specific conditions for Citizens' Band (CB) radio and ancillary equipment (speech and non-speech) |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 301 489-17 V3.2.4 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems: Harmonised Standard for ElectroMagnetic Compatibility |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 301 489-17 V3.3.1 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems: Harmonised Standard for ElectroMagnetic Compatibility |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| ETSI EN 301 489-26 V2.3.2 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 26: Specific conditions for CDMA 1x spread spectrum Base Stations, repeaters and ancillary equipment |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 301 489-3 V2.1.1 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz : Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 301 489-3 V2.3.2 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz: Harmonised Standard for ElectroMagnetic Compatibility |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| ETSI EN 301 489-5 V2.2.1 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech) and Terrestrial Trunked Radio (TETRA); Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| ETSI EN 301 489-5 V2.3.1 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech) and Terrestrial Trunked Radio (TETRA): Harmonised Standard for ElectroMagnetic Compatibility |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| ETSI EN 301 489-9 V2.1.1 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 9: Specific conditions for wireless microphones, similar Radio Frequency (RF) audio link equipment, cordless audio and in-ear monitoring devices: Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| FCC PART 15:2014 |
Radio frequency devices |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| FCC PART 15:2025 |
Radio frequency devices |
RE: 30 MHz ~ 40 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| FCC PART 18:2014 |
Industral,scientific and medical equipment |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| FCC PART 18:2025 |
Industral,scientific and medical equipment |
RE: 9 kHz ~ 40 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| IEC 60601-1-2:2007 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 2 500 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| IEC 60601-1-2:2014 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE: 0.15 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: CD ±8 ㎸ AD: ±15 ㎸ RS: 10 V/m, 80 ㎒ ~ 2 700 ㎒ RS(Proximity fields): 9 V/m ~ 28 V/m, 385 ㎒~5 785 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 6 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| IEC 60601-1-2:2014+A1:2020 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE: 0.15 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: CD ±8 ㎸ AD: ±15 ㎸ RS: 10 V/m, 80 ㎒ ~ 2 700 ㎒ RS(Proximity fields): 9 V/m ~ 28 V/m, 385 ㎒~5 785 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 6 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % Proximity magnetic fields: 8 A/m ~ 65 A/m, 30 ㎑ ~ 13.56 ㎒ TI:-600 V ~ 200 V |
소재지-1 |
| IEC 60601-2-10: 2012+A1: 2016 |
Medical electrical equipment – Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS 202 Electromagnetic compatibility–Requireme nts and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 2 500 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| IEC 60601-2-18: 2009 |
Medical electrical equipment – Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS 202 Electromagnetic compatibility – Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 2 500 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| IEC 61000-3-2:2014 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
(Exception) 3 phase equipment |
16 A |
소재지 |
| IEC 61000-3-2:2014 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) |
16 A |
소재지-1 |
| IEC 61000-3-2:2018 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
(Exception) 3 phase equipment |
16 A |
소재지 |
| IEC 61000-3-2:2018 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) |
16 A |
소재지-1 |
| IEC 61000-3-2:2018+A1:2020+A2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) |
16 A |
소재지-1 |
| IEC 61000-3-3:2013+AMD1:2017+AMD2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
(Exception) 3 phase equipment |
16 A |
소재지 |
| IEC 61000-3-3:2013+AMD1:2017+AMD2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
(Exception) 3 phase equipment |
16 A |
소재지-1 |
| IEC 61000-4-11:2004/ISH1:2017 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
(0 ~ 100) % |
소재지 |
| IEC 61000-4-11:2004/ISH1:2017 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
(0 ~ 100) % |
소재지-1 |
| IEC 61000-4-11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
(0 ~ 100) % |
소재지-1 |
| IEC 61000-4-11:2020+COR:2022 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
(0 ~ 100) % |
소재지-1 |
| IEC 61000-4-2:2008 |
Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test |
±30 kV |
소재지 |
| IEC 61000-4-2:2008 |
Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test |
±30 kV |
소재지-1 |
| IEC 61000-4-3:2006+AMD1:2008+AMD2:2010 |
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
10 V/m |
소재지 |
| IEC 61000-4-3:2006+AMD1:2008+AMD2:2010 |
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
10 V/m |
소재지-1 |
| IEC 61000-4-34:2005+AMD1:2009 |
Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques — Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase |
Voltage: Max. 3 Φ, 400 V Current: Max. 32 A V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61000-4-4:2012 |
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
±4 kV |
소재지 |
| IEC 61000-4-4:2012 |
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
±5.5 kV |
소재지-1 |
| IEC 61000-4-5:2014 |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
(제외항목) 3 phase equipment |
±6 kV |
소재지 |
| IEC 61000-4-5:2014 |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test |
±7.0 kV |
소재지-1 |
| IEC 61000-4-5:2014+AMD1:2017 CSV |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test |
±6.0 kV |
소재지 |
| IEC 61000-4-5:2014+AMD1:2017 CSV |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test |
±7.0 kV |
소재지-1 |
| IEC 61000-4-6:2013 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
10 V |
소재지 |
| IEC 61000-4-6:2013 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
10 V |
소재지-1 |
| IEC 61000-4-6:2013/COR1:2015 |
Electromagnetic compatibility (EMC) — Part 4-6:Testing and measurement techniques — Immunity to conducted disturbances, induced by radio-frequency fields |
10 V |
소재지-1 |
| IEC 61000-4-8:2009 |
Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test |
30 A/m |
소재지 |
| IEC 61000-4-8:2009 |
Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test |
30 A/m |
소재지-1 |
| IEC 61000-6-1:2016 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V ,150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61000-6-2:2016 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V ,150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61000-6-3:2006+AMD1:2010 CSV |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| IEC 61000-6-3:2020 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential, environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| IEC 61000-6-4:2006+AMD1:2010 CSV |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| IEC 61000-6-4:2018 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| IEC 61204-3:2016 |
Low voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz DP: 30 MHz ~ 300 MHz H/F : 16 A ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-1:2012 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-1:2012 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-2:2012 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-2:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-3:2012 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-3:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-4:2012 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-4:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-5:2012 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with interfaces according to IEC 61784-1, CP 3 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-5:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with interfaces according to IEC 61784-1, CP 3 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-6:2012 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61326-2-6:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 61547:2009 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD : ±8 kV RS: 80 MHz ~ 1 GHz 3 V/m EFT : ±1 kV SURGE : ±2 kV CS: 150 kHz ~ 80 MHz 3 V V-DIP: max 100 % |
소재지 |
| IEC 61547:2009 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 62040-2:2016 |
Uninterruptible power system (UPS) Part 2 : Electromagnetic Compatibility (EMC) requirements [exception] Immunity to Low-frequency signals IEC 61000-2-2 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 GHz H/F: 16 A ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 1 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 80 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| IEC 62493:2015 |
Assessment of Lighting Equipment related to Human Exposure to Electromagnetic Fields |
EMF : 20 kHz ~ 10 MHz |
소재지 |
| IEC 62493:2015 |
Assessment of Lighting Equipment related to Human Exposure to Electromagnetic Fields |
EMF : 20 kHz ~ 10 MHz |
소재지-1 |
| IEC 62493:2015+A1:2022 |
Assessment of Lighting Equipment related to Human Exposure to Electromagnetic Fields |
EMF : 20 kHz ~ 10 MHz |
소재지-1 |
| KS C 9040-2:2017 |
무정전전원장치(UPS) - 제2부: 전자파적합성(EMC) 요구사항 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C 9547:2020 |
일반 조명기기 — 전자파적합성(EMC) 내성 요구사항 |
ESD : ±8 kV RS: 80 MHz ~ 1 GHz 3 V/m EFT : ±1 kV SURGE : ±2 kV CS: 150 kHz ~ 80 MHz 3 V V-DIP: max 100 % |
소재지 |
| KS C 9547:2020 |
일반 조명기기 — 전자파적합성(EMC) 내성 요구사항 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C 9610-4-11:2020 |
전자파적합성 (EMC) -제 4-11 부 : 시험 및 측정기술 -전압강하 , 순간 정전 , 전압변동 내성 시험 |
(0 ~ 100) % |
소재지 |
| KS C 9610-4-11:2020 |
전자파적합성 (EMC) -제 4-11 부 : 시험 및 측정기술 -전압강하 , 순간 정전 , 전압변동 내성 시험 |
(0 ~ 100) % |
소재지-1 |
| KS C 9610-4-2:2017 |
전자파적합성(EMC)-제4-2부:시험 및 측정기술-정전기 방전 내성시험 |
±30 kV |
소재지 |
| KS C 9610-4-2:2017 |
전자파적합성(EMC)-제4-2부:시험 및 측정기술-정전기 방전 내성시험 |
±30 kV |
소재지-1 |
| KS C 9610-4-3:2017 |
전자파적합성(EMC)-제4-3부:시험 및 측정 기술-방사 RF 전자기장 내성 시험 |
10 V/m |
소재지 |
| KS C 9610-4-3:2017 |
전자파적합성(EMC)-제4-3부:시험 및 측정 기술-방사 RF 전자기장 내성 시험 |
10 V/m |
소재지-1 |
| KS C 9610-4-4:2020 |
전자파적합성(EMC)-제4-4부:시험 및 측정 기술-전기적 빠른 과도현상/버스트 내성 시험 |
±4 kV |
소재지 |
| KS C 9610-4-4:2020 |
전자파적합성(EMC)-제4-4부:시험 및 측정 기술-전기적 빠른 과도현상/버스트 내성 시험 |
±5.5 kV |
소재지-1 |
| KS C 9610-4-5:2020 |
전자파적합성(EMC) -제4-5부: 시험 및 측정 기술 — 서지 내성시험
(Exception) 3상 기기 |
±6 kV |
소재지 |
| KS C 9610-4-5:2020 |
전자파적합성(EMC) -제4-5부: 시험 및 측정 기술 — 서지 내성시험 |
±7.0 kV |
소재지-1 |
| KS C 9610-4-5:2023 |
전자파적합성(EMC) -제4-5부: 시험 및 측정 기술 — 서지 내성시험 |
±7.0 kV |
소재지-1 |
| KS C 9610-4-6:2020 |
전자파적합성 (EMC) -제 4-6 부 : 시험 및 측정기술 -전도성 RF 전자기장 내성시험 |
10 V |
소재지 |
| KS C 9610-4-6:2020 |
전자파적합성 (EMC) -제 4-6 부 : 시험 및 측정기술 -전도성 RF 전자기장 내성시험 |
10 V |
소재지-1 |
| KS C 9610-4-8:2017 |
전자파적합성 (EMC) -제 4-8 부 : 시험 및 측정기술 -전원 주파수 자기장 내성 시험 |
30 A/m |
소재지 |
| KS C 9610-4-8:2017 |
전자파적합성 (EMC) -제 4-8 부 : 시험 및 측정기술 -전원 주파수 자기장 내성 시험 |
30 A/m |
소재지-1 |
| KS C 9610-6-1:2019 |
전자파적합성(EMC) -제 6-1 부 : 일반표준 -주거, 상업 및 경공업 환경에서 사용하는 기기의 전자파 내성표준 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V ,150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C 9610-6-2:2019 |
전자파적합성 (EMC) -제 6-2 부 : 일반표준 -산업 환경에서 사용하는 기기의 전자파 내성 표준 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V ,150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C 9610-6-3:2017 |
전자파적합성(EMC)-제6-3부:일반기준 - 주거용, 상업용 및 경공업 환경에서 사용하는 기기의 전자파 방해 표준 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| KS C 9610-6-3:2023 |
전자파적합성(EMC)-제6-3부:일반기준 - 주거용, 상업용 및 경공업 환경에서 사용하는 기기의 전자파 방해 표준 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| KS C 9610-6-4:2017 |
전자파적합성(EMC)-제6-4부:일반기준-산업 환경에서 사용하는 기기의 전자파 방해 표준 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| KS C 9610-6-4:2022 |
전자파적합성(EMC)-제6-4부:일반기준-산업 환경에서 사용하는 기기의 전자파 방출 표준 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| KS C 9811:2019 |
산업, 과학, 의료용(ISM) 기기-무선 주파수 방해 특성-허용기준 및 측정방법
(Exception) 6.2.2 2종기기 30 m 측정법 |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz |
소재지-1 |
| KS C 9814-1:2022 |
전자파적합성(EMC) - 가정용전기 기기, 전동 공구 및 유사 기기의 요구 사항 - 제1부 : 방출 |
CE : 9 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 9 kHz ~ 6 GHz |
소재지-1 |
| KS C 9814-2:2022 |
전자파적합성(EMC)-가정용전기 기기, 전동 공구 및 유사 기기의 요구 사항 - 제2부: 내성 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C 9815:2023 |
조명 기기 및 유사 기기의 무선 방해 특성 측정 허용기준과 측정 방법 |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
소재지 |
| KS C 9815:2023 |
조명 기기 및 유사 기기의 무선 방해 특성 측정 허용기준과 측정 방법 |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
소재지-1 |
| KS C 9832:2019 |
멀티미디어기기 전자파 장해방지 시험 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| KS C 9832:2024 |
멀티미디어기기 전자파 장해방지 시험 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| KS C 9835:2019 |
멀티미디어기기 전자파 내성 시험 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C CISPR 24:2014 |
전기자기적합성(EMC) ─ 정보 기기(ITE)의 전기자기 내성 시험방법 및 측정의 한계값 |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C IEC 60601-1-2:2012 |
의료용 전기기기 - 제 1-2부: 기본 안전 및 필수 성능에 관한 일반 요구사항 - 부가표준 : 전기자기 적합성 - 요구사항 및 시험 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 2 500 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| KS C IEC 60601-1-2:2014 |
의료용 전기기기 — 제1-2부: 기본 안전 및 필수 성능에 관한 일반 요구사항 — 보조표준: 전자파 장해 — 요구사항 및 시험 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 2 500 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % |
소재지-1 |
| KS C IEC 60601-1-2:2020 |
의료용 전기기기 — 제1-2부: 기본 안전 및 필수 성능에 관한 일반 요구사항 — 보조표준: 전자파 장해 — 요구사항 및 시험 |
CE: 0.15 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A ESD: CD ±8 ㎸ AD: ±15 ㎸ RS: 10 V/m, 80 ㎒ ~ 2 700 ㎒ RS(Proximity fields): 9 V/m ~ 28 V/m, 385 ㎒~5 785 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 6 V, 0.15 ㎒ ~ 80 ㎒ MF: 30 A/m V-DIP: (0 ~ 100) % Proximity magnetic fields: 8 A/m ~ 65 A/m, 30 ㎑ ~ 13.56 ㎒ TI:-600 V ~ 200 V |
소재지-1 |
| KS C IEC 61000-4-34:2009 |
시험 및 측정 기술 — 상당 입력전류 16 A를 초과하는 기기에 대한 전압 강하, 순간 정전 및 전압 변동 내성 시험 |
전압: 최대 3 Φ, 400 V 전류: 최대 32 A V-DIP : (0 ~ 100) % |
소재지-1 |
| KS C IEC 61204-3:2003 |
저전압 직류 전원 장치 -제 3 부 : 전기 자기 적합성 (EMC) |
ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 3 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS X 3124:2020 |
무선기기의 공통 전자파적합성 시험방법
(Exception) 9.6 차량 환경에서의 과도현상 및 서지 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS X 3124:2024 |
무선기기의 공통 전자파적합성 시험방법 |
RE: 30 MHz ~ 6 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~ 80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| KS X 3125:2020 |
특정소출력무선기기 전자파적합성시험방법 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS X 3125:2024 |
특정소출력무선기기 전자파적합성시험방법 |
RE: 30 MHz ~ 6 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~ 80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| KS X 3126:2020 |
무선데이터 통신시스템용 특정소출력 무선기기 전자파적합성 시험방법 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS X 3126:2024 |
무선데이터 통신시스템용 특정소출력 무선기기 전자파적합성 시험방법 |
RE: 30 MHz ~ 6 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~ 80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| KS X 3127:2014 |
간이무선국 전자파적합성 시험방법 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS X 3127:2024 |
간이무선국 전자파적합성 시험방법 |
RE: 30 MHz ~ 6 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~ 80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| KS X 3130:2014 |
음성 및 음향신호 전송용 특정소출력무선기기 전자파적합성 시험방법 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS X 3130:2024 |
음성 및 음향신호 전송용 특정소출력무선기기 전자파적합성 시험방법 |
RE: 30 MHz ~ 6 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~ 80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| KS X 3131:2014 |
생활무전기 전자파적합성 시험방법 |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ±2 kV SURGE : ±2 kV CS : 10 V, 150 kHz ~ 230 MHz M/F : 30 A/m V-DIP : (0 ~ 100) % |
소재지-1 |
| KS X 3131:2024 |
생활무전기 전자파적합성 시험방법 |
RE: 30 MHz ~ 6 GHz CE: 9 kHz ~ 30 MHz ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~ 80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| QCVN 112:2017/BTTTT |
National technical regulation on general electromagnetic compatibility for radio broadband data transmission equipment |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz H/F: 16 A ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| QCVN 118:2018/BTTTT |
National technical regulation on Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE:30 ㎒ ∼ 18 ㎓, CE:150 ㎑ ∼ 30 ㎒, H/F: 16 A |
소재지-1 |
| QCVN 18:2022/BTTTT |
National technical regulation on General Electromagnetic Compatibility for Radio Communications Equipment |
RE: 30 MHz ~ 6 GHz CE: 150 kHz ~ 30 MHz H/F: 16 A ESD : ±8 kV RS : 3 V/m, 80 MHz ~ 6 GHz EFT : ±1 kV SURGE : ±2 kV CS : 3 V, 150 kHz ~80 MHz V-DIP : (0 ~ 100) % TI:-600 V ~ 200 V |
소재지-1 |
| VCCI:2014 |
Voluntary Control Council for Interference by Information Technology Equipment |
RE: 30 MHz ~ 6 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| VCCI-CISPR 32:2016 |
Voluntary Control Council for Interference by Information Technology Equipment |
RE: 30 MHz ~ 18 GHz CE: 9 kHz ~ 30 MHz |
소재지-1 |
| ▶ 소프트웨어 |
| EN 18031-1:2024 |
Common security requirements for radio equipment - Part 1: Internet connected radio equipment |
- |
소재지-1 |
| EN 18031-2:2024 |
Common security requirements for radio equipment - Part 2: radio equipment processing data, namely Internet connected radio equipment, childcare radio equipment, toys radio equipment and wearable radio equipment |
- |
소재지-1 |
| EN 18031-3:2024 |
Common security requirements for radio equipment - Part 3: Internet connected radio equipment processing virtual money or monetary value |
- |
소재지-1 |
| ETSI EN 303 645:2024 |
CYBER; Cyber security for consumer Internet of Things: Baseline requirements |
- |
소재지-1 |
| IEC 62443-3-3:2013 |
Industrial communication networks - Network and system security - Part 3-3: System security requirements and security levels |
- |
소재지-1 |
| IEC 62443-4-1:2018 |
Security for industrial automation and control systems - Part 4-1: Secure product development lifecycle requirements |
- |
소재지-1 |
| IEC 62443-4-2:2019 |
Security for industrial automation and control systems - Part 4-2: Technical security requirements for IACS components |
- |
소재지-1 |
| IEC 81001-5-1:2021 |
Health software and health IT systems safety, effectiveness and security.Part 5-1: Security — Activities in the product life cycle |
- |
소재지-1 |
| IEC TR 60601-4-5:2021 |
Medical electrical equipment - Part 4-5: Guidance and interpretation - Safety-related technical security specifications |
- |
소재지-1 |
| KS X IEC 62443-3-3:2013 |
산업 통신 네트워크 — 네트워크 및 시스템 보안 — 제3-3부: 시스템 보안 요구사항 및 보안 등급 |
- |
소재지-1 |
| KS X IEC 62443-4-1:2018 |
산업제어시스템 보안 — 제4-1부: 안전한 제품 개발 생명주기 요구사항 |
- |
소재지-1 |
| KS X IEC 62443-4-2:2019 |
산업제어시스템 보안 — 제4-2부: 산업제어시스템 컴포넌트의 기술적 보안 요구사항 |
- |
소재지-1 |
| KS X ISO/IEC 25051:2014 |
소프트웨어 공학 — 시스템 및 소프트웨어 품질 요구사항 및 평가(SQuaRE) — 즉시 사용 가능한 소프트웨어 제품(RUSP)의 품질 요구사항 및 테스팅 지침 |
- |
소재지-1 |
| KS X ISO/IEC 25023:2016 |
시스템 및 소프트웨어 공학 — 시스템 및소프트웨어 품질 요구사항 및평가(SQuaRE) — 시스템 및소프트웨어 제품 품질 측정 |
- |
소재지-1 |
| ISO/IEC TS 25058:2024 |
Systems and software engineering - Systems and software Quality Requirements and Evaluation (SQuaRE) - Guidance for quality evaluation of artificial intelligence (AI) systems |
- |
소재지-1 |
| ISO/IEC TR 24028:2020 |
Information technology — Artificial intelligence — Overview of trustworthiness in artificial intelligence |
- |
소재지-1 |
| KS X ISO/IEC TR 24028:2020 |
정보 기술 — 인공지능 — 인공지능의 신뢰성 개요 |
- |
소재지-1 |
| ISO/IEC TS 4213:2022 |
Information technology — Artificial intelligence — Assessment of machine learning classification performance |
AC voltage range at lead: (5 ~ 600) V, DC voltage range at lead: (1 ~ 600) V, AC/DC current range at lead: (0.005 ~ 20.000) A, Auto range |
소재지-1 |
| KS X ISO/IEC TS 4213:2022 |
정보 기술 — 인공지능 — 기계 학습 분류 성능에 대한 평가 |
AC voltage range at lead: (5 ~ 600) V, DC voltage range at lead: (1 ~ 600) V, AC/DC current range at lead: (0.005 ~ 20.000) A, Auto range |
소재지-1 |
| 안내서-0995-05(2025.1.10) |
의료기기의 사이버보안 허가·심사 가이드라인(민원인 안내서) |
- |
소재지-1 |
| UL 2900-1:2023 |
Software Cybersecurity for Network-Connectable Products, Part 1: General Requirements |
- |
소재지-1 |
| UL 2900-2-1:2023 |
Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems |
- |
소재지-1 |
| IEC 60335-1:2020 |
Household and similar electrical appliances - Safety - Part 1: General requirements Annex R |
- |
소재지-1 |
| KS C IEC 60335-1:2022 |
가정용 및 이와 유사한 전기기기의 안전성 ― 제1부: 일반 요구사항 부속서 R |
- |
소재지-1 |
| KC 60335-1:2022 |
가정용 및 이와 유사한 전기기기의 안전성 ― 제1부: 일반 요구사항 부속서 R |
- |
소재지-1 |
| ▶ 에너지효율 |
| 10 CFR Part 430, Subpart B, Appendix Y1 |
Uniform Test Method for Measuring the Energy Consumption of Battery Chargers |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| 10 CFR Part 430, Subpart B, Appendix Z |
Uniform Test Method for Measuring the Energy Consumption of External Power Supplies |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
10 CFR Part 430, Subpart B, Appendix H |
Uniform Test Method for Measuring the Power Consumption of Television Sets |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| AS/NZS 4665.1:2005 + A1:2009 |
Performance of external power supplies, Part 1:Test method and energy performance mark |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| AS/NZS 4665.2:2005 +A1:2009 |
Performance of external power supplies, Part 2:Minimum energy performance standard (MEPS) requirements |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| AS/NZS 62087.1:2010 |
Power consumption of audio, video and related equipment, Part 1: Methods of measurement |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| AS/NZS 62087.2.2:2011 |
Power consumption of MEPS audio, video and related equipment, Part 2.2:Minimum energy performance standards(MEPS) and energy rating label requirements for television sets |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| AS/NZS IEC 62301:2014 |
Household electrical appliances - Measurement of standby power |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| CAN/CSA C62301-11 |
Household electrical appliances - Measurement of standby power |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| CSA C381.1-08 |
Test method for calculating the energy efficiency of single voltage external ac-dc and ac-ac power supplies |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| CSA C381.1-17 |
Energy performance of external ac-dc and ac-ac power supplies |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| CSA C381.2-17 |
Energy performance of battery-charging systems and uninterruptible power supplies |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| EN 50563:2011 |
External a.c. - d.c. and a.c. - a.c. power supplies – Determination of no-load power and average efficiency of active modes |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| EN 50564:2011 |
Electrical and electronic household and office equipment - Measurement of low power consumption |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| EN 62301:2005 |
Household electrical appliances - Measurement of standby power |
Input voltage: Max. 300 V Input current: Max. 20 A |
소재지 |
| EPA Energy Star Program Requirements |
Product Specification for single Voltage External Ac-Dc and Ac-Ac Power supplies Eligibility Criteria Version 2.0 |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| EPA Energy Star Program Requirements |
Product Specification for Displays Eligibility Criteria Version 8.0 |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| EPA Energy Star Program Requirements |
Product Specification for Televisions Eligibility Criteria Version 9.0 |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| EPA Energy Star Program Requirements |
Product Specification for Computers Eligibility Criteria Version 9.0 |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| EPA Energy Star Program Requirements |
Product Specification for Audio/Video Eligibility Criteria Version 3.0 |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087:2008 (Ed. 2.0) |
Methods of measurement for the power consumption of audio, video and related equipment |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087:2011 (Ed. 3.0) |
Methods of measurement for the power consumption of audio, video and related equipment |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087-1:2015 |
Audio, video, and related equipment - Determination of power consumption - Part 1: General |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087-2:2023 |
Audio, video, and related equipment - Determination of power consumption - Part 2: Signals and media |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087-3:2023 |
Audio, video, and related equipment - Determination of power consumption - Part 3: Television sets |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087-4:2015 |
Audio, video, and related equipment - Determination of power consumption - Part 4: Video recording equipment |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087-5:2015 |
Audio, video, and related equipment - Determination of power consumption - Part 5: Set-top-boxes |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087-6:2015 |
Audio, video, and related equipment - Determination of power consumption - Part 6: Audio equipment |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62087-7:2018 |
Audio, video, and related equipment - Determination of power consumption - Part 7: Computer monitors |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62301:2005 (Ed. 1.0) |
Household electrical appliances – Measurement of standby power |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| IEC 62301:2011 |
Household electrical appliances - Measurement of standby power |
Input voltage: Max. 300 V Input current: Max. 20 A |
소재지 |
| IEC 62301:2011 (Ed. 2.0) |
Household electrical appliances – Measurement of standby power |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| KS C IEC 62301:2011 |
가정용 전기 기기의 대기전력 측정 방법 |
입력 전압: 300 V 이하 입력 주파수: (50/60) Hz 입력 전력: 10 kV 이하 |
소재지-2 |
| KS C IEC 62301:2011 |
가정용 전기기기의 대기전력 측정방법 |
입력전압: 최대 300 V 입력전류: 최대 20 A |
소재지 |
| PNS IEC 62087:2013 |
Methods of measurement for the power consumption of audio, video and related equipment |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| SANS 62087:2010 |
Methods of measurement for the power consumption of audio, video and related equipment |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
| SANS 62301:2012 |
Household electrical appliances - Measurement of standby power |
Input Voltage: less than 300 V Input frequency: (50/60) Hz Input power: less than 10 kV |
소재지-2 |
산업통상자원부 고시 제2022-33호 (2022.02.15) |
대기전력저감 프로그램 운용규정 3. 프린터 4. 팩시밀리 5. 복사기 6. 스캐너 7. 복합기 8. 자동절전제어장치 10. 오디오 11. DVD플레이어 12. 라디오카세트 13. 전자레인지 15. 도어폰 17. 비데 20. 손건조기 21. 서버 22. 디지털컨버터 23. 유무선공유기 |
3. 3 000 W 이하 4. 3 000 W 이하 5. 5 000 W 이하 6. 1 000 W 이하 7. 5 000 W 이하 8. - 10. 1 000 W 이하 11. 150 W 이하 12. 1 000 W 이하 13. 4 000 W 이하 15. 100 W 이하 17. 2 000 W 이하 20. 3 000 W 이하 21. 3 000 W 이하 22. 100 W 이하 23. - |
소재지-2 |
| 기후에너지환경부고시 제2026-25호(2026.01.23.) |
대기전력저감 프로그램 운용규정 3. 프린터 5. 복사기 6. 스캐너 8. 자동절전제어장치 10. 오디오 11. DVD플레이어 12. 라디오 카세트 13. 전자레인지 15. 도어폰 16. 유무선전화기 20. 손건조기 21. 서버 23. 유무선공유기 |
3. 최대 3 000 W 5. 최대 5 000 W 6. 최대 1 000 W 8. - 10. 최대 1 000 W 11. 최대 150 W 12. 최대 1 000 W 13. 최대 4 000 W 15. 최대 100 W 16. 최대 150 W 20. 최대 3 000 W 21. 최대 3 000 W 23. - |
소재지 |
| 산업통상자원부고시 제2025-145호(2025.08.13.) |
효율관리기자재 운용규정 20. 어댑터·충전기 26. 텔레비전수상기 37. 셋톱박스 42. 사이니지 디스플레이 44. 모니터 49. 컴퓨터 |
20. 150 W 이하 26. (47 ~ 216) cm 37. 150 W 이하 42. (30.48 ~ 154.94) cm 44. 153 cm 이하 |
소재지-2 |
| 기후에너지환경부고시 제2026-26호(2026.01.23.) |
효율관리기자재 운용규정 12. 선풍기 14. 백열전구 15. 형광램프 17. 안정기내장형램프 20. 어댑터, 충전기 26. 텔레비전 수상기 38. 컨버터 내장형 LED램프 39. 컨버터 외장형 LED램프 42. 사이니지 디스플레이 44. 모니터 47. 직관형 LED램프(컨버터 외장형) 49. 컴퓨터 |
12. (20 ~ 41) cm 14. (25 ~ 150) W 15. 최대 55 W 17. (5 ~ 60) W 20. 최대 150 W 26. (47 ~ 216) cm 38/39/47. 전광선속: 최대 250 000 lm 38/39/47. 연색지수: 최대 100 38/39/47. 상관색온도: 최대 10 000 K 42. (30.48 ~ 154.94) cm 44. 최대 153 cm 49. 입력전압 : 최대 300 V 49. 입력전류 : 최대 20 A |
소재지 |
| 기후에너지환경부고시 제2026-4호(2026.01.12.) |
고효율에너지기자재 보급촉진에 관한 규정 09. LED 유도등 18. 등기구 19. LED 램프 20. 스마트LED조명 |
09/18/19/20. 입력전압 : 최대 300 V 09/18/19/20. 입력전류 : 최대 20 A 09/18/19/20. 온도 : (-40 ~ 150) °C 09/18/19/20. 전광선속 : 최대 250 000 lm 09/18/19/20. 연색지수 : 최대 100 09/18/19/20. 상관색온도 : 최대 10 000 K |
소재지 |
| 기후에너지환경부고시 제2026-26호(2026.01.23.) |
효율관리기자재 운용규정 12. 선풍기 20. 어댑터, 충전기 26. 텔레비전 수상기 38. 컨버터 내장형 LED램프 39. 컨버터 외장형 LED램프 42. 사이니지 디스플레이 44. 모니터 47. 직관형 LED램프(컨버터 외장형) 49. 컴퓨터 |
12. (20 ~ 41) cm 20. 최대 150 W 26. (47 ~ 216) cm 38/39/47. 전광선속: 최대 250 000 lm 38/39/47. 연색지수: 최대 100 38/39/47. 상관색온도: 최대 10 000 K 42. (30.48 ~ 154.94) cm 44. 최대 153 cm 49. 입력전압 : 최대 300 V 49. 입력전류 : 최대 20 A |
부속시설-3 |
| 기후에너지환경부고시 제2026-4호(2026.01.12.) |
고효율에너지기자재 보급촉진에 관한 규정 18. 등기구 19. LED 램프 |
18-19. 입력전압 : 최대 300 V 18-19. 입력전류 : 최대 20 A 18-19. 온도 : (-40 ~ 150) °C 18-19. 전광선속 : 최대 250 000 lm 18-19. 연색지수 : 최대 100 18-19. 상관색온도 : 최대 10 000 K |
부속시설-3 |
| 기후에너지환경부고시 제2026-25호(2026.01.23.) |
대기전력저감 프로그램 운용규정 3. 프린터 5. 복사기 6. 스캐너 8. 자동절전제어장치 10. 오디오 11. DVD플레이어 12. 라디오 카세트 13. 전자레인지 15. 도어폰 16. 유무선전화기 20. 손건조기 21. 서버 23. 유무선공유기 |
3. 최대 3 000 W 5. 최대 5 000 W 6. 최대 1 000 W 8. - 10. 최대 1 000 W 11. 최대 150 W 12. 최대 1 000 W 13. 최대 4 000 W 15. 최대 100 W 16. 최대 150 W 20. 최대 3 000 W 21. 최대 3 000 W 23. - |
부속시설-3 |
| ▶ 환경 및 신뢰성 |
| EN 50155:2021 |
Railway applications – Rolling stock - Electronic equipment {Exception} 13.4.3 DC Power supply test 13.4.9 Electromagnetic compatibility test 13.4.12 Rapid temperature variation test |
Temperature: (-40 ~ 100) °C Humidity: Max. 95 % R.H. Insulation resistance: DC 500 V Elec. Strength: AC 1 500 V Frequency : (5 ~ 3 000) Hz Acceleration: Max. 150 m/s² Shock Acc.: Max. 500 m/s² |
소재지-2 |
| EN 60068-2-1:2007 |
Environmental Testing - Part 2-1 :Tests - Test A : Cold (Exception) 6.6.1 Temperature -50 ℃, -55 ℃, -65 ℃ |
Temperature: -40 ℃ ~ 5 ℃ |
소재지-2 |
| EN 60068-2-14:2009 |
Environmental testing - Part 2-14: Tests - Test N: Change of temperature [Exception] 9 Test Nc: Rapid change of temperature, two - fluid - bath method |
Temperature: -60 ℃ ~ 150 ℃ |
소재지-2 |
| EN 60068-2-2:2007 |
Environmental testing - Part 2-2: Tests – Test B: Dry heat [Exception] 6.5.2 Temperature 155 ℃, 175 ℃, 200 ℃, 250 ℃, 315 ℃, 400 ℃, 500 ℃, 630 ℃, 800 ℃, 1 000 ℃ |
Temperature: 20 ℃ ~ 150 ℃ |
소재지-2 |
| EN 60068-2-27:2009 |
Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock [Exception] 5. Severities : Peak acceleration more than 500 m/s² |
Max. Acceleration: 500 m/s² |
소재지-2 |
| EN 60068-2-30:2005 |
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Temperature: Max. 55 ℃ Humidity: Max. 95 % R.H. |
소재지-2 |
| EN 60068-2-30:2025 |
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Temperature : (22 ~ 55) ℃ Humidity : (45 ~ 95) % R.H. |
소재지 |
| EN 60068-2-31:2008 |
Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
Heights : (25 ~ 1 500) mm Mass : (1 ~ 50) kg |
소재지-2 |
| EN 60068-2-38:2009 |
Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
Temperature : (-10 ~ 65) ℃ Humidity : (80 ~ 95) % R.H. |
소재지 |
| EN 60068-2-52:2018 |
Environmental testing - Part 2: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
(15 ~ 35) ℃ NaCl 5 % 40 ℃, 93 % R.H. 23 ℃, (45 ∼ 55) % R.H. |
소재지 |
| EN 60068-2-6:2008 |
Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
Resonance frequency : (10 ~ 2 000) Hz Acceleration : (1 ~ 98) m/s² |
소재지 |
| EN 60068-2-6:2008 |
Environmental testing – Part 2-6: Tests - Test Fc: Vibration (sinusoidal) [Exception] 5.1.1 lowe frequency (0.1 Hz, 1 Hz) 5.1.2 Upper frequency (5 000 Hz) |
Vibration frequency: 5 Hz ~ 3 000 Hz Acceleration: Max. 200 ㎨ |
소재지-2 |
| EN 60068-2-64:2008+A1:2019 |
Environmental testing Part 2-64: Tests Test Fh: Vibration, broadband random and guidance [Exception] 8.4.1 General – Non-Gaussian vibration testing, Figure 5 |
Frequency : (5 ~ 3 000) Hz Acceleration: Max. 150 m/s² Shock Acc.: Max. 500 m/s² |
소재지-2 |
| EN 60068-2-67:1996+A1:2019 |
Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components |
Temperature: 85 ℃ Humidity: 85 % R.H |
소재지-2 |
| EN 60068-2-75:2014 |
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J, 2 J, 5 J, 10 J, 20 J |
소재지 |
| EN 60068-2-75:2014 |
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests [Exception] Test Eha, Ehc : 0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J, 50 J |
Test Eha, Ehc : 2 J, 5 J, 10 J, 20 J Test Ehb : 0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J |
소재지-2 |
| EN 60068-2-78:2013 |
Environmental testing – Part 2-78: Tests – Test Cab: Damp heat, steady state |
30 ℃, 93 % R.H. 30 ℃, 85 % R.H. 40 ℃, 93 % R.H. 40 ℃, 85 % R.H. |
소재지 |
| EN 60068-2-78:2013 |
Environmental testing - Part 2-78 : Tests-Test Cab : Damp heat, steady state |
Temperature: (30 ~ 40) ℃ Humidity: (85 ~ 93) % R.H. |
소재지-2 |
| EN 60529:1991+A1:2000+A2:2013 |
Degrees of protection provided by enclosures (IP Code) [Exception] IPX9 |
IP1X, IP2X, IP3X, IP4X, IP5X, IP6X IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7, IPX8 |
소재지-2 |
| EN 60529:1991+AMD1:2000+AMD2:2013 |
Degrees of protection provided by enclosures(IP Code) |
IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7, IP1X, IP2X, IP3X, IP4X, IP5X, IP6X |
소재지 |
| EN 60695-10-2:2014 |
Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
Max 170 ℃, (20 ± 0.2) N |
소재지 |
| EN 60695-2-10:2013 |
Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
(550 ~ 960) ℃ |
소재지 |
| EN 61373:2010 |
Railway applications - Rolling stock equipment - Shock and vibration tests [Exception] 10 Shock test conditions (1 000 m/s²) |
Frequency (5 ~ 3 000) Hz Accelation Max. 150 m/s² Shock Acc. Max. 500 m/s² |
소재지-2 |
| EN 62262:2002 |
Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IK00, IK01, IK02, IK03, IK04, IK05, IK06, IK07, IK08, IK09, IK10 |
소재지 |
| EN 62262:2002+A1:2021 |
Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IK00, IK01, IK02, IK03, IK04, IK05, IK06, IK07, IK08, IK09, IK10 |
소재지 |
| EN 62262:2002+A1:2021 |
Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IK00 ~ IK10 |
소재지-2 |
| EN IEC 60068-2-1:2025 |
Environmental testing – Part 2-1:Tests – Test A:Cold |
Temperature : (-40 ~ 5) ℃ (Exception : -50 ℃, -55 ℃, -60 ℃) |
소재지 |
| EN IEC 60068-2-11:2021 |
Environmental Testing Part 2-11: Tests - Test Ka: Salt mist |
35 ℃, NaCl 5 % |
소재지 |
| EN IEC 60068-2-11:2021 |
Environmental testing - Part 2-11: Tests - Test Ka: Salt mist |
Temperature: 35 ℃ spray: (1.0 ~ 2.0) mL/h NaCl: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) |
소재지-2 |
| EN IEC 60068-2-2:2025 |
Environmental testing – Part 2-2:Tests – Test B:Dry heat |
Temperature : (30 ~ 125) ℃ (Exception : 155 ℃, 175 ℃, 200 ℃, 250 ℃, 315 ℃, 400 ℃, 500 ℃, 630 ℃, 800 ℃, 1000 ℃) |
소재지 |
| EN IEC 60068-2-38:2021 |
Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
Temperature : (-10 ~ 65) ℃ Humidity : (80 ~ 95) % R.H. |
소재지 |
| EN IEC 60068-2-38:2021 |
Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
Temperature: -10 ℃ ~ 65 ℃ Humidity: Max. 95 % R.H. |
소재지-2 |
| EN IEC 60068-2-52:2018 |
Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
Temperature: (23 ~ 50) ℃ Humidity: (45 ~95) % R.H. Spray: (1.0 ~ 2.0) mL/h NaCl: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) |
소재지-2 |
| EN IEC 60695-2-10:2021 |
Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
(550 ~ 960) ℃ |
소재지 |
| IEC 60068-2-1:2007 |
Environmental Testing - Part 2-1:Tests - Test A : Cold [Exception] 6.6.1 Temperature -50 ℃, -55 ℃, -65 ℃ |
Temperature: -40 ℃ ~ 5 ℃ |
소재지-2 |
| IEC 60068-2-1:2025 |
Environmental testing – Part 2-1:Tests – Test A:Cold |
Temperature : (-40 ~ 5) ℃ (Exception : -50 ℃, -55 ℃, -60 ℃) |
소재지 |
| IEC 60068-2-11:2021 |
Environmental testing - Part 2-11: Tests - Test Ka: Salt mist |
35 ℃, NaCl 5 % |
소재지 |
| IEC 60068-2-11:2021 |
Environmental testing - Part 2-11: Tests - Test Ka: Salt mist |
Temperature: 35 ℃ spray: (1.0 ~ 2.0) mL/h NaCl: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) |
소재지-2 |
| IEC 60068-2-14:2023 |
Environmental testing — Part 2-14: Tests — Test N: Change of temperature |
Temperature : (-40 ~ 125) ℃ |
소재지 |
| IEC 60068-2-14:2023 |
Environmental testing - Part 2-14: Tests - Test N: Change of temperature [Exception] 9 Test Nc: Rapid change of temperature, two - fluid - bath method |
Temperature: -60 ℃ ~ 150 ℃ |
소재지-2 |
| IEC 60068-2-2:2007 |
Environmental testing - Part 2-2: Tests – Test B: Dry heat [Exception] 6.5.2 Temperature 155 ℃, 175 ℃, 200 ℃, 250 ℃, 315 ℃, 400 ℃, 500 ℃, 630 ℃, 800 ℃, 1 000 ℃ |
Temperature: 20 ℃ ~ 150 ℃ |
소재지-2 |
| IEC 60068-2-2:2025 |
Environmental testing – Part 2-2:Tests – Test B:Dry heat |
Temperature : (30 ~ 125) ℃ (Exception : 155 ℃, 175 ℃, 200 ℃, 250 ℃, 315 ℃, 400 ℃, 500 ℃, 630 ℃, 800 ℃, 1 000 ℃) |
소재지 |
| IEC 60068-2-27:2008 |
Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock [Exception] 5. Severities : Peak acceleration more than 500 m/s² |
Max. Acceleration: 500 m/s² |
소재지-2 |
| IEC 60068-2-30:2005 |
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Temperature: Max. 55 ℃ Humidity: Max. 95 % R.H. |
소재지-2 |
| IEC 60068-2-30:2025 |
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Temperature : (22 ~ 55) ℃ Humidity : (45 ~ 95) % R.H. |
소재지 |
| IEC 60068-2-31:2008 |
Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
Heights : (25 ~ 1 500) mm Mass : (1 ~ 50) kg |
소재지-2 |
| IEC 60068-2-38:2009 |
Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
Temperature : (-10 ~ 65) ℃ Humidity : (80 ~ 95) % R.H. |
소재지 |
| IEC 60068-2-38:2021 |
Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
Temperature : (-10 ~ 65) ℃ Humidity : (80 ~ 95) % R.H. |
소재지 |
| IEC 60068-2-38:2021 |
Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
Temperature: -10 ℃ ~ 65 ℃ Humidity: Max. 95 % R.H. |
소재지-2 |
| IEC 60068-2-52:2017 |
Environmental testing - Part 2: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
(15 ~ 35) ℃ NaCl 5 % 40 ℃, 93 % R.H. 23 ℃, (45 ∼ 55) % R.H. |
소재지 |
| IEC 60068-2-52:2017 |
Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
Temperature: (23 ~ 50) ℃ Humidity: (45 ~95) % R.H. Spray: (1.0 ~ 2.0) mL/h NaCl: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) |
소재지-2 |
| IEC 60068-2-6:2007 |
Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
Resonance frequency : (10 ~ 2 000) Hz Acceleration : (1 ~ 98) m/s² |
소재지 |
| IEC 60068-2-6:2007 |
Environmental testing – Part 2-6: Tests - Test Fc: Vibration (sinusoidal) [Exception] 5.1.1 lowe frequency (0.1 Hz, 1 Hz) 5.1.2 Upper frequency (5 000 Hz) |
Vibration frequency: 5 Hz ~ 3 000 Hz Acceleration: Max. 200 ㎨ |
소재지-2 |
| IEC 60068-2-64:2008+A1:2019 |
Environmental testing Part 2-64: Tests Test Fh: Vibration, broadband random and guidance [Exception] 8.4.1 General – Non-Gaussian vibration testing, Figure 5 |
Frequency : (5 ~ 3 000) Hz Acceleration: Max. 150 m/s² Shock Acc.: Max. 500 m/s² |
소재지-2 |
| IEC 60068-2-67:1995+A1:2019 |
Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components |
Temperature: 85 ℃ Humidity: 85 % R.H |
소재지-2 |
| IEC 60068-2-75:2014 |
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests [Exception] Test Eha, Ehc : 0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J, 50 J |
Test Eha, Ehc : 2 J, 5 J, 10 J, 20 J Test Ehb : 0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J |
소재지-2 |
| IEC 60068-2-75:2014 |
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J, 2 J, 5 J, 10 J, 20 J |
소재지 |
| IEC 60068-2-78:2012 |
Environmental testing – Part 2-78: Tests – Test Cab: Damp heat, steady state |
30 ℃, 93 % R.H. 30 ℃, 85 % R.H. 40 ℃, 93 % R.H. 40 ℃, 85 % R.H. |
소재지 |
| IEC 60068-2-78:2012 |
Environmental testing - Part 2-78 : Tests-Test Cab : Damp heat, steady state |
Temperature: (30 ~ 40) ℃ Humidity: (85 ~ 93) % R.H. |
소재지-2 |
| IEC 60529:1989+A1:1999+A2:2013 |
Degrees of protection provided by enclosures (IP Code) [Exception] IPX9 |
IP1X, IP2X, IP3X, IP4X, IP5X, IP6X IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7, IPX8 |
소재지-2 |
| IEC 60529:1989+AMD1:1999+AMD2:2013 |
Degrees of protection provided by enclosures(IP Code) |
IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7, IP1X, IP2X, IP3X, IP4X, IP5X, IP6X |
소재지 |
| IEC 60571:2012 |
Railway applications - Electronic equipment used on rolling stock 12.2.4 Cold start test 12.2.5 Dry heat test 12.2.6 Damp heat test, cyclic 12.2.10 Insulation test 12.2.11 Salt mist test 12.2.12 Vibration, shock and bump test 12.2.15 Low temperature storage test |
Temp./Humid. (-40 ~ 100) °C, (80 ~ 95) % R.H. Insulation resistance DC 500 V / DC 1 000 V NaCl: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) Frequency (5 ~ 3 000) Hz Accelation Max. 150 m/s² Shock Acc. Max. 500 m/s² |
소재지-2 |
| IEC 60695-10-2:2014 |
Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
Max 170 ℃, (20 ± 0.2) N |
소재지 |
| IEC 60695-2-10:2013 |
Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
(550 ~ 960) ℃ |
소재지 |
| IEC 60695-2-10:2021 |
Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
(550 ~ 960) ℃ |
소재지 |
| IEC 61373:2010 |
Railway applications - Rolling stock equipment - Shock and vibration tests [Exception] 10 Shock test conditions (1 000 m/s²) |
Frequency (5 ~ 3 000) Hz Accelation Max. 150 m/s² Shock Acc. Max. 500 m/s² |
소재지-2 |
| IEC 62262:2002 |
Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IK00, IK01, IK02, IK03, IK04, IK05, IK06, IK07, IK08, IK09, IK10 |
소재지 |
| IEC 62262:2002/AMD1:2021 |
Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IK00, IK01, IK02, IK03, IK04, IK05, IK06, IK07, IK08, IK09, IK10 |
소재지 |
| IEC 62262:2002+A1:2021 |
Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IK00 ~ IK10 |
소재지-2 |
| KS C 5078:2015 |
자동차용 사고영상기록장치 7.3 내환경시험 |
온도: (-40 ~ 100) ℃ 진동주파수: (5 ~ 3 000) Hz 가속도: Max. 200 ㎨ |
소재지-2 |
| KS C IEC 60068-2-1:2007 |
환경시험 – 제2-1부:시험 – 시험 A:내한성 시험 |
온도 : (-40 ~ 5) ℃ (-50 ℃, -55 ℃, -60 ℃ 제외) |
소재지 |
| KS C IEC 60068-2-1:2007 |
환경시험 - 제2-1부: 시험-시험A: 내한성시험 [제외항목] 6.6.1 온도 -50 ℃, -55 ℃, -65 ℃ -50 ℃, -55 ℃, -65 ℃ |
온도: -40 ℃ ~ 5 ℃ |
소재지-2 |
| KS C IEC 60068-2-11:2021 |
환경 시험 — 제2-11부: 시험 — 시험 Ka: 염수분무 |
35 ℃, NaCl 5 % |
소재지 |
| KS C IEC 60068-2-11:2021 |
환경 시험 - 제2-11부: 시 험 - 시험 Ka: 염수분무 |
온도: 35 ℃ 분무량: (1.0 ~ 2.0) mL/h 염도: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) |
소재지-2 |
| KS C IEC 60068-2-14:2023 |
환경시험 – 제2-14부: 시험 – 시험 N : 온도 변화 |
온도 : (-40 ~ 125) ℃ |
소재지 |
| KS C IEC 60068-2-14:2023 |
환경시험 - 제2-14부: 시험 -시험N: 온도변화 [제외항목] 9 시험 Nc: 온도의 급변(2액조법) |
Temperature: -60 ℃ ~ 150 ℃ |
소재지-2 |
| KS C IEC 60068-2-2:2007 |
환경시험 – 제2-2부:시험 – 시험 B:내열성 시험 |
온도 : (30 ~ 125) ℃ (155 ℃, 175 ℃, 200 ℃, 250 ℃, 315 ℃, 400 ℃, 500 ℃, 630 ℃, 800 ℃, 1000 ℃ 제외) |
소재지 |
| KS C IEC 60068-2-2:2007 |
환경시험 - 제2-2부: 시험-시험B: 내열성시험 [제외항목] 6.5.2 온도 155 ℃, 175 ℃, 200 ℃, 250 ℃, 315 ℃, 400 ℃, 500 ℃, 630 ℃, 800 ℃, 1 000 ℃ |
온도: 20 ℃ ~ 150 ℃ |
소재지-2 |
| KS C IEC 60068-2-27:2008 |
환경 시험-제2-27부 : 시험-시험 Ea와 지침:충격 [제외항목] 5. 가혹도: 첨두가속도 500 m/s² 이상 |
최대가속도 500 m/s² |
소재지-2 |
| KS C IEC 60068-2-30:2005 |
환경 시험 — 제2-30부: 시험 — 시험 Db와 지침: 주기적 내습(12 h + 12 h 주기) |
온도 : (22 ~ 55) ℃ 습도 : (45 ~ 95) % R.H. |
소재지 |
| KS C IEC 60068-2-30:2005 |
환경 시험 – 제2-30부: 시험-시험 Db와 지침: 주기적 내습 (12 h + 12 h 주기) |
온도: Max. 55 ℃ 습도: Max. 95 % R.H. |
소재지-2 |
| KS C IEC 60068-2-31:2008 |
환경 시험 - 제2-31부:시험 - 시험 Ec:주로 장비형 시편에 사용하는 거친 취급시 충격 |
높이 : (25 ~ 1 500) mm 질량 : (1 ~ 50) kg |
소재지-2 |
| KS C IEC 60068-2-38:2021 |
환경시험 – 제2-38부: 시험 – 시험 Z/AD: 복합 온도/습도 사이클 시험 |
온도 : (-10 ~ 65) ℃ 습도 : (80 ~ 95) % R.H. |
소재지 |
| KS C IEC 60068-2-38:2021 |
환경 시험 - 제2-38부: 시험 - 시험 Z/AD: 복합 온도/습도 사이클 시험 |
온도: -10 ℃ ~ 65 ℃ 습도: Max. 95 % R.H. |
소재지-2 |
| KS C IEC 60068-2-52:2017 |
환경 시험 - 제2-52부: 시험 - 시험 Kb : 염수분무, 사이클(염화소듐 용액) |
(15 ~ 35) ℃ NaCl 5 % 40 ℃, 93 % R.H. 23 ℃, (45 ∼ 55) % R.H. |
소재지 |
| KS C IEC 60068-2-52:2017 |
환경 시험 - 제2-52부: 시험 - 시험 Kb: 염수분무, 사이클(염화소듐 용액) |
온도: (23 ~ 50) ℃ 습도: (45 ~95) % R.H. 분무량: (1.0 ~ 2.0) mL/h 염도: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) |
소재지-2 |
| KS C IEC 60068-2-6:2015 |
환경시험 – 제2-6부:시험 – 시험 Fc:진동(정현파) |
공진주파수 : (10 ~ 2 000) Hz 진동가속도 : (1 ~ 98) m/s² |
소재지 |
| KS C IEC 60068-2-6:2015 |
환경 시험 – 제2-6부: 시험 – 시험 Fc: 진동(정현파) [제외항목] 5.1.1 하한주파수 (0.1 Hz, 1 Hz) 5.1.2 상한주파수 (5 000 Hz) |
Vibration frequency: 5 Hz ~ 3 000 Hz Acceleration: Max. 200 ㎨ |
소재지-2 |
| KS C IEC 60068-2-64:2019 |
환경 시험 - 제2-64부: 시험 - 시험 Fh: 광대역 랜덤 진동 시험 및 지침 [제외항목] 8.4.1 일반 - 비가우스 진동시험, 그림 5 |
진동주파수: (5 ~ 3 000) Hz 진동가속도: Max. 150 m/s² 충격가속도: Max. 500 m/s² |
소재지-2 |
| KS C IEC 60068-2-67:2019 |
환경 시험 - 제2-67부: 시험 - 시험 Cy: 주로 부품을 대상으로 하는 습열, 정상 상태, 가속 시험 |
온도: 85 ℃ 습도: 85 % R.H |
소재지-2 |
| KS C IEC 60068-2-75:2014 |
환경시험 – 제2-75부: 시험 – 시험 Eh: 해머 시험 |
0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J, 2 J, 5 J, 10 J, 20 J |
소재지 |
| KS C IEC 60068-2-75:2014 |
환경 시험 - 제2-75부: 시험 - 시험 Eh: 해머 시험 [제외항목] 시험 Eha, Ehc : 0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J, 50 J |
시험 Eha, Ehc : 2 J, 5 J, 10 J, 20 J 시험 Ehb : 0.14 J, 0.2 J, 0.35 J, 0.5 J, 0.7 J, 1 J |
소재지-2 |
| KS C IEC 60068-2-78:2012 |
환경시험 – 제2-78부: 시험 – 시험 Cab: 안정 상태의 내습성 시험 |
30 ℃, 93 % R.H. 30 ℃, 85 % R.H. 40 ℃, 93 % R.H. 40 ℃, 85 % R.H. |
소재지 |
| KS C IEC 60068-2-78:2012 |
환경 시험 – 제2-78부: 시험 – 시험 Cab: 안전 상태의 내습성 시험 |
온도: (30 ~ 40) ℃ 습도: (85 ~ 93) % R.H. |
소재지-2 |
| KS C IEC 60255- 21-1:1988 |
전기계전기 제21-1부: 보호 계전기와 보호 기기의 진동,충격,충돌,지진 시험 - 진동 시험 용어 |
진동주파수: (5 ~ 3 000) Hz 충격가속도: Max. 500 m/s² |
소재지-2 |
| KS C IEC 60255- 21-2:1988 |
전기계전기 제21 - 2부: 보호계전기와 보호 기기의 진동, 충격, 충돌, 지진 시험 - 지진 시험 |
충격가속도: Max. 500 m/s² |
소재지-2 |
| KS C IEC 60529:2013 |
외함의 밀폐 보호등급 구분(IP코드) |
IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7, IP1X, IP2X, IP3X, IP4X, IP5X, IP6X |
소재지 |
| KS C IEC 60529:2013 |
외함의 밀폐 보호등급 구분(IP 코드) [제외항목] IPX9 |
IP1X, IP2X, IP3X, IP4X, IP5X, IP6X IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7, IPX8 |
소재지-2 |
| KS C IEC 60571:2012 |
철도 적용 - 철도 차량용 전자기기 12.2.4 내한성 시험 12.2.5 내열성 시험 12.2.6 내습 사이클 시험 12.2.10 절연 시험 12.2.11 염수 분무 시험 12.2.12 진동, 충격 및 충돌 시험 12.2.15 저온저장 시험 |
온도/습도 (-40 ~ 100) °C, (80 ~ 95) % R.H. 절연저항 DC 500 V / DC 1 000 V NaCl: (4.5 ~ 5.5) % pH: (6.5 ~ 7.2) 진동주파수 (5 ~ 3 000) Hz 진동가속도 Max. 150 m/s² 충격가속도 Max. 500 m/s² |
소재지-2 |
| KS C IEC 60664- 1:2020 |
저압공급계통 내 기기의 절연협조 - 제 1부 : 원칙, 요구사항, 시험 |
Vac : 5 000 V 이하 Vdc : 1 000 V 이하 |
소재지-2 |
| KS C IEC 60695-10-2:2014 |
화재 위험성 시험 - 제10-2부: 비정상적인 열 - 볼 프레셔(ball pressure) 시험 방법 |
최대 170 ℃, (20 ± 0.2) N |
소재지 |
| KS C IEC 60695-11-5:2016 |
화재 위험성 시험-제11-5부:시험 불꽃 - 바늘 불꽃 시험방법 - 장치, 확인 시험 배치 및 지침 |
불꽃 길이 : (12 ± 1) mm |
소재지 |
| KS C IEC 60695-2-10:2013 |
화재 위험성 시험 - 제2-10부: 글로잉/핫와이어 기반 시험방법 - 글로우와이어 장치 및 일반 시험 절차 |
(550 ~ 960) ℃ |
소재지 |
| KS C IEC 60695-2-11:2021 |
화재 위험성 시험 — 제2-11부: 글로잉/핫 와이어 시험방법 — 최종 제품에 대한 글로 와이어 인화성 시험방법 (GWEPT) |
(550 ~ 960) ℃ |
소재지 |
| KS C IEC 60695-2-12:2021 |
화재 위험성 시험 — 제2-12부: 글로잉/ 핫 와이어 시험방법 — 재료에 대한 글로-와이어 인화성 지수(GWFI) 시험방법 |
(550 ~ 960) ℃ |
소재지 |
| KS C IEC 60695-2-13:2021 |
화재 위험성 시험 — 제2-13부: 글로잉/ 핫 와이어 시험방법 — 재료에 대한 글로-와이어 착화온도(GWIT) 시험방법 |
(550 ~ 960) ℃ |
소재지 |
| KS C IEC 61373:2010 |
철도 적용 - 철도차량 장치 - 충격 및 진동시험 [제외항목] 10 충격 시험 조건 (1 000 m/s²) |
진동주파수: (5 ~ 3 000) Hz 진동가속도: Max. 150 m/s² 충격가속도: Max. 500 m/s² |
소재지-2 |
| KS C IEC 62262:2021 |
외부 기계적 충격에 대한 전기기기용 외함의 보호 등급 (IK 코드) |
IK00 ~ IK10 |
소재지-2 |
| KS C IEC 62262:2021 |
외부 기계적 충격에 대한 전기기기용 외함의 보호 등급(IK 코드) |
IK00, IK01, IK02, IK03, IK04, IK05, IK06, IK07, IK08, IK09, IK10 |
소재지 |
| KS R 1034:2023 |
자동차 부품 진동 시험 방법 |
진동주파수: (5 ~ 3 000) Hz 진동가속도: Max. 150 m/s² |
소재지-2 |
| KS R 9144:2021 |
철도차량 부품의 진동시험 방법 |
진동주파수: (5 ~ 3 000) Hz 진동가속도: Max. 150 m/s² |
소재지-2 |
| KS R 9186:2021 |
철도신호보안 부품 진동시험 방법 |
진동주파수: (5 ~ 3 000) Hz 진동가속도: Max. 150 m/s² 충격가속도: Max. 500 m/s² |
소재지-2 |
| KS R 9187:2021 |
철도신호 보안부품 - 충격 시험방법 [제외항목] 4종 ,5종 |
충격가속도: Max. 500 m/s² |
소재지-2 |
| KS R 9193:2022 |
철도신호 보안부품의 절연 저항 및 내전압 시험 방법 |
절연저항: Max. DC 500 V 내전압: Max. AC 5 000 V |
소재지-2 |
| KS R 9197:2022 |
철도차량의 절연저항 및 내전압 시험방법 |
절연저항: Max. DC 1 000 V 내전압: Max. AC 5 000 V |
소재지-2 |
| MIL-STD-810F:2000 |
DEPARTMENT OF DEFENSE Test Method Standard for Environmental Engineering Considerations and Laboratory Tests
501.4 High temperature Method 502.4 Low temperature Method 507.4 Humidity Method 514.5 Vibration |
Temperature : (30 ~ 125) ℃ Humidity : (-40 ~ 5) ℃ Humidity : (30 ~ 98) % R.H. Resonance frequency : (10 ~ 2 000) Hz Acceleration : (1 ~ 98) m/s² |
소재지 |
| MIL-STD-810F:NOTICE-3:2003 |
DEPARTMENT OF DEFENSE Test Method Standard for Environmental Engineering Considerations and Laboratory Tests
501.4 High temperature Method 502.4 Low temperature Method 507.4 Humidity Method 514.5 Vibration |
Temperature : (30 ~ 125) ℃ Humidity : (-40 ~ 5) ℃ Humidity : (30 ~ 98) % R.H. Resonance frequency : (10 ~ 2 000) Hz Acceleration : (1 ~ 98) m/s² |
소재지 |
| MIL-STD-810G:2008 |
DEPARTMENT OF DEFENSE Test Method Standard for : Environmental Engineering Considerations and Laboratory Tests
501.5 High temperature Method 502.5 Low temperature Method 507.6 Humidity Method 514.6 Vibration |
Temperature : (30 ~ 125) ℃ Humidity : (-40 ~ 5) ℃ Humidity : (30 ~ 98) % R.H. Resonance frequency : (10 ~ 2 000) Hz Acceleration : (1 ~ 98) m/s² |
소재지 |
| MIL-STD-810G:w/Change 1 2014 |
DEPARTMENT OF DEFENSE Test Method Standard : Environmental Engineering Considerations and Laboratory Tests
501.5 High temperature Method 502.5 Low temperature Method 507.6 Humidity Method 514.6 Vibration |
Temperature : (30 ~ 125) ℃ Humidity : (-40 ~ 5) ℃ Humidity : (30 ~ 98) % R.H. Resonance frequency : (10 ~ 2 000) Hz Acceleration : (1 ~ 98) m/s² |
소재지 |
| ▶ 음향특성 |
| ISO 3744:2010 |
Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
[Exception] 7.2.5 Cylindrical measurement surface 7.2.6 Combination measurement surface |
Frequency range (100 ~ 20 000) Hz |
소재지 |
| KS I ISO 3744:2010 |
음향 - 음압을 사용한 소음원의 음향파워레벨과 음향에너지레벨 결정 - 반사면 위 준자유음장에서 공학적 방법
[제외항목] 7.2.5 원통 측정면 7.2.6 조합 측정면 |
주파수 범위 (100 ~ 20 000) Hz |
소재지 |
| ▶ 가정용 전기기기 |
| EN IEC 62368-1:2020/A11:2020 |
Audio/video, information and communication technology equipment –Part 1: Safety requirements 4.1.9 Electrical measuring instruments 5.2 Classification and limits of electrical energy sources 5.4.1.4 Maximum operating temperatures for materials, components and systems 9.3 Touch temperature limits 5.4.5 Antenna terminal insulation 5.4.9 Electric strength test 5.5.2.2 Capacitor discharge after disconnection of a connector 5.6.4 Requirements for protective bonding conductors 5.7 Prospective touch voltage, touch current and protective conductor current 6.2.2 Power source circuit classifications Annex B.2.5 Input test |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ |
부속시설-1 |
| IEC 62368-1:2018 |
Audio/video, information and communication technology equipment –Part 1: Safety requirements 4.1.9 Electrical measuring instruments 5.2 Classification and limits of electrical energy sources 5.4.1.4 Maximum operating temperatures for materials, components and systems 9.3 Touch temperature limits 5.4.5 Antenna terminal insulation 5.4.9 Electric strength test 5.5.2.2 Capacitor discharge after disconnection of a connector 5.6.4 Requirements for protective bonding conductors 5.7 Prospective touch voltage, touch current and protective conductor current 6.2.2 Power source circuit classifications Annex B.2.5 Input test |
Input Voltage: Max. 600 V Input Current: Max. 20 A Working Voltage: Max. peak 20 kV Leakage Current: Max. 10 mA Earth Continuity: Max. 12 V, Max. 60 A Electric strength: Max. 5 kV, Max. 100 mA Insulation Resistance: Max. 4 000 MΩ |
부속시설-1 |
| KC 62368-1:2021 |
오디오/비디오 및 정보통신 기술기기 제1부 : 안전 요구사항 4.1.9 전기 측정 계기 5.2 전기 에너지원의 분류 및 한계(치) 5.4.1.4 재질, 부품 및 시스템에 대한 최대 동작 온도 9.3 접촉 온도 한계치 5.4.5 안테나 단자 절연 5.4.9 내전압 시험 5.5.2.2 커넥터의 연결을 끊은(차단) 후 캐패시터 방전 5.6.4 보호 본딩 도체에 대한 요구 사항 5.7 예상 접촉 전압, 접촉 전류 및 보호 도체 전류 6.2.2 전원 공급원(Power Source) 회로 분류 부속서 B.2.5 입력 시험 |
입력전압: 최대 600 V 입력전류: 최대 20 A 동작전압: 최대 peak 20 kV 누설전류: 최대 10 mA 접지연속성: 12 V, 60 A 절연내력: 5 kV, 100 mA 절연저항: 최대 4 000 MΩ |
부속시설-1 |
| ▶ 전자기적합성 |
| CISPR 14-1:2020 |
Electromagnetic compatibitliy - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Disturbance Power : 30 MHz ~ 300 MHz RE: 9 kHz ~ 1 GHz CE : 9 kHz ~ 30 MHz |
부속시설-2 |
| CISPR 15:2018 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) 7. Method of insertion loss measurement |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
부속시설-2 |
| CISPR 32:2012 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| CISPR 32:2015+A1:2019 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| EN 55032:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| EN 55032:2015+A1:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| EN 55032:2015+A11:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| EN 61000-4-2:2009 |
Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test |
±30 Kv |
부속시설-2 |
| EN 61000-6-4:2007+A1:2011 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 1 GHz |
부속시설-2 |
| EN IEC 55014-1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 1: Emission |
Disturbance Power : 30 MHz ~ 300 MHz RE: 9 kHz ~ 1 GHz CE : 9 kHz ~ 30 MHz |
부속시설-2 |
| EN IEC 55015:2019 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
부속시설-2 |
| EN IEC 55015:2019/A11:2020 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
부속시설-2 |
| EN IEC 61000-6-3:2021 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| EN IEC 61000-6-4:2019 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 1 GHz |
부속시설-2 |
| IEC 61000-4-2:2008 |
Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test |
±30 kV |
부속시설-2 |
| IEC 61000-6-3:2006+AMD1:2010 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| IEC 61000-6-3:2020 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| IEC 61000-6-4:2006+AMD1:2010 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 1 GHz |
부속시설-2 |
| IEC 61000-6-4:2018 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 1 GHz |
부속시설-2 |
| KS C 9610-4-2:2017 |
전자파적합성(EMC)-제4-2부:시험 및 측정기술-정전기 방전 내성시험 |
±30 kV |
부속시설-2 |
| KS C 9610-6-3:2023 |
전자파적합성(EMC)-제6부:일반 기준-제3절:주거용, 상업용 및 경공업 환경에서 사용하는 기기의 전자파 방해 표준 |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |
| KS C 9610-6-4:2022 |
전자파적합성(EMC)-제6-4부:일반기준-산업 환경에서 사용하는 기기의 전자파 방해 표준 |
CE: 9 kHz ~ 30 MHz RE: 30 MHz ~ 1 GHz |
부속시설-2 |
| KS C 9814-1:2022 |
전자파적합성(EMC) - 가정용전기 기기, 전동 공구 및 유사 기기의 요구 사항 - 제1부 : 방출 |
Disturbance Power : 30 MHz ~ 300 MHz RE: 9 kHz ~ 1 GHz CE : 9 kHz ~ 30 MHz |
부속시설-2 |
| KS C 9815:2023 |
조명 기기 및 유사 기기의 무선 방해 특성 측정 허용기준과 측정 방법 |
RE : 9 kHz ~ 1 000 MHz CE : 9 kHz ~ 30 MHz |
부속시설-2 |
| KS C 9832:2024 |
멀티미디어기기 전자파 장해방지 시험 |
RE: 30 MHz ~ 1 GHzCE: 9 kHz ~ 30 MHz |
부속시설-2 |