| ▶ 전자기적합성 |
| ANSI C63.4:2014 |
American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
(Exception) 12.3 Measurement of TV interface devices |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| ANSI C63.4a:2017 |
American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz Amendment 1: Test Site Validation
(Exception) 12.3 Measurement of TV interface devices |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| CISPR 11:2009+A1:2010 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| CISPR 11:2015+A1:2016+A2:2019 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| CISPR 11:2024 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| CISPR 14-1:2005+A2:2011 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE : 150 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 30 MHz ~ 1 000 MHz |
소재지 |
| CISPR 14-1:2016 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE : 150 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 30 MHz ~ 1 000 MHz |
소재지 |
| CISPR 14-1:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE : 9 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 9 kHz ~ 6 GHz |
소재지 |
| CISPR 14-2:2015 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD : ± 8 kV RS : 80 MHz ~ 1 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| CISPR 14-2:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| CISPR 15:2018 |
Amendment 1 - Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) Loop diameter (3 m and 4 m) of Table 7 and 8 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 1 000 MHz |
소재지 |
| CISPR 15:2018+A1:2024 |
Amendment 1 - Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) Loop diameter (3 m and 4 m) of Table 7 and 8 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 1 000 MHz |
소재지 |
| CISPR 16-2-1:2014+A1:2017 |
Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
CE: 9 kHz ~ 30 MHz |
소재지 |
| CISPR 16-2-1:2014+COR1:2020 |
Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
CE: 9 kHz ~ 30 MHz |
소재지 |
| CISPR 16-2-2:2010 |
Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power |
DP: 30 MHz ~ 1 GHz |
소재지 |
| CISPR 16-2-3:2016+A1:2019 |
Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
RE: 9 kHz ~ 18 GHz |
소재지 |
| CISPR 16-2-3:2016+A1:2019+A2:2023 |
Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
RE: 9 kHz ~ 18 GHz |
소재지 |
| CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz Conducted Differential Voltage Emission(VE) : 30 MHz ~ 2 150 MHz |
소재지 |
| CISPR 32:2015+A1:2019 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz Conducted Differential Voltage Emission(VE) : 30 MHz ~ 2 150 MHz |
소재지 |
| CISPR 35:2016 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V MF : 1 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 12015:2014 |
Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks - Emission |
CE : 150 kHz ~ 30 MHz RE : 30 kHz ~ 1 GHz Harmonic : ≤16 A (1Φ) Flicker ≤16 A (1Φ) |
소재지 |
| EN 12015:2020 |
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission |
CE : 150 kHz ~ 30 MHz RE : 30 kHz ~ 1 GHz Harmonic : ≤16 A (1Φ) Flicker ≤16 A (1Φ) |
소재지 |
| EN 12016:2013 |
Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks - Immunity |
ESD : ± 15 kV RS : 80 MHz ~ 2 675 GHz, 30 V/m EFT : ± 4 kV Surge : ± 2.5 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100 ) % |
소재지 |
| EN 301 843-1 V2.2.1:2017 |
ElectroMagnetic Compatibility (EMC) standard for marine radio equipment and services; Harmonised Standard for electromagnetic compatibility; Part 1: Common techinical requirements |
CE : 10 kHz ~ 30 MHz RE : 150 kHz ~ 2 GHz ESD : ± 8 kV RS : 10 V/m, 80 MHz ~ 2.7 GHz EFT : ± 2 kV SURGE: ± 1 kV CS : 3 V, 150 kHz ~ 80 MHz Voltage Variation : V ±20 % Variation (1.5 s) F ±10 % Variation (5 s) V 100% dip (60 s) |
소재지 |
| EN 301 843-6 V2.2.1:2017 |
ElectroMagnetic Compatibility (EMC) standard for marine radio equipment and services; Harmonised Standard for electromagnetic compatibility; Part 6: Specific conditions for Earth Station on board Vessels operating in frequency bands above 3 GHz |
CE : 10 kHz ~ 30 MHz RE : 150 kHz ~ 2 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz EFT : ± 2 kV SURGE: ± 1 kV CS : 3 V, 150 kHz ~ 80 MHz Voltage Variation : V ±20 % Variation (1.5 s) F ±10 % Variation (5 s) V 100% dip (60 s) |
소재지 |
| EN 50121-1:2006+AC:2008 |
Railway Application - Electromagnetic Compatibility - Part 1: General |
ESD : ± 8 kV RS : 80 MHz ~ 3 GHz EFT : ± 4 kV Surge : ± 4 kV CS : 150 kHz ~ 230 MHz MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 50121-1:2017 |
Railway application - Electromagnetic compatibility - Part 1: General |
ESD : ± 8 kV RS : 80 MHz ~ 3 GHz EFT : ± 4 kV Surge : ± 4 kV CS : 150 kHz ~ 230 MHz MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 50121-2:2006+AC:2008 |
Railway Application - Electromagnetic Compatibility - Part 2: Emission of the whole reilway system to the outside world |
RE : 9 kHz ~ 1 GHz |
소재지 |
| EN 50121-2:2017 |
Railway application - Electromagnetic compatibility - Part 2: Emission of the whole reilway system to the outside world |
RE : 9 kHz ~ 1 GHz |
소재지 |
| EN 50121-3-2:2016 |
Railway Application - Electromagnetic Compatibility - Part 3 - 2 Rolling Stock _ Apparatus |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz. 10 V |
소재지 |
| EN 50121-3-2:2016+A1:2019 |
Railway application - Electromagnetic compatibility - Part 3-2: Rolling Stock _ Apparatus |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz. 10 V |
소재지 |
| EN 50121-4:2016 |
Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus |
CE : 150 kHz ~ 30 MHz RE: 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 300 A/m (DC) 100 A/m (AC) Pulsed Magnetic : 300 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 50121-4:2016+A1:2019 |
Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus |
CE : 150 kHz ~ 30 MHz RE: 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 300 A/m (DC) 100 A/m (AC) Pulsed Magnetic : 300 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 50130-4:2011 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems |
ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 100 MHz, 10 V V-dip : (0 ~ 100 ) % |
소재지 |
| EN 50130-4:2011+A1:2014 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems |
ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 100 MHz, 10 V V-dip : (0 ~ 100 ) % |
소재지 |
| EN 50270:2015+AC:2016 |
Electromagnetic compatibility (EMC) - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
CE : 9 kHz ~ 30 MHz RE : 30 MHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 50498:2010 |
Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
(Exception) 7.3 Conducted transient Disturbances 7.4 Conducted transient immunity |
RE : 30 MHz ~ 1 GHz |
소재지 |
| EN 55011:2016 |
Industrial, scientific and medical equipment-Radio-frequency disturbance characteristics – Limits and methods of measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| EN 55011:2016+A11:2020 |
Industrial, scientific and medical equipment-Radio-frequency disturbance characteristics – Limits and methods of measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| EN 55011:2016+A1:2017 |
Industrial, scientific and medical equipment-Radio-frequency disturbance characteristics – Limits and methods of measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| EN 55011:2016+A2:2021 |
Industrial, scientific and medical equipment-Radio-frequency disturbance characteristics – Limits and methods of measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| EN 55014-1:2017 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE : 150 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 30 MHz ~ 1 000 MHz |
소재지 |
| EN 55014-1:2017+A11:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE : 150 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 30 MHz ~ 1 000 MHz |
소재지 |
| EN 55014-2:2015 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD : ± 8 kV RS : 80 MHz ~ 1 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| EN 55032:2015 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz Conducted Differential Voltage Emission(VE) : 30 MHz ~ 2 150 MHz |
소재지 |
| EN 55032:2015+A11:2020 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz Conducted Differential Voltage Emission(VE) : 30 MHz ~ 2 150 MHz |
소재지 |
| EN 55032:2015+A1:2020 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz Conducted Differential Voltage Emission(VE) : 30 MHz ~ 2 150 MHz |
소재지 |
| EN 55035:2017 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V MF : 1 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 55035:2017+A11:2020 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V MF : 1 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-1-2:2015 |
Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral standard: Electromagnetic compatibility – Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-1-2:2015+A1:2021 |
Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral standard: Electromagnetic distrubances – Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-10:2015 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators (IEC 60601-2-10:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-10:2015+A1:2016 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators (IEC 60601-2-10:2012+AMD2:2023)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-10:2015+A2:2024 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators (IEC 60601-2-10:2012+AMD2:2023)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-18:2015 |
Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment Clauses 201.17 and 202 Electromagnetic compatibility (IEC60601-2-18:2009) |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-19:2009 |
Medical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators (IEC 60601-2-19:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-19:2009+A11:2011 |
Medical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators (IEC 60601-2-19:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-19:2009+A1:2016 |
Medical electrical equipment – Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators (IEC 60601-2-19:2009+A1:2016)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-20:2009+A11:2011 |
Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (IEC 60601-2-20:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-20:2009+A1:2016 |
Medical electrical equipment – Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (IEC 60601-2-20:2009+A1:2016)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-21:2009+A11:2011 |
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (IEC 60601-2-21:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-21:2009+A1:2016 |
Medical electrical equipment – Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (IEC 60601-2-21:2009+A1:2016)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-22:2013 |
Medical electrical equipment – Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment (IEC 60601-2-22:2007+A1:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-24:2015 |
Medical electrical equipment – Part 2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers (IEC 60601-2-24:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-25:2015 |
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs Clauses 201.17 and 202 Electromagnetic compatibility (IEC 60601-2-25:2011) |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-26:2015 |
Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs (IEC 60601-2-26:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-27:2014 |
Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment Clauses 201.17 and 202 Electromagnetic compatibility (IEC 60601-2-27:2011+corrigendum May 2012) |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-34:2014 |
Medical electrical equipment Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment (IEC 60601-2-34:2011)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-37:2008 |
Medical electrical equipment - Part 2-37: Particular requirements for the safety and essential performance of ultrasonic medical diagnostic and monitoring equipment Clauses 201.17 and 202.6 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-37:2008+A1:2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment (IEC 60601-2-37:2007)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202.6 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-3:2015 |
Medical electrical equipment – Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-3:2015+A1:2016 |
Medical electrical equipment – Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-3:2015+A2:2024 |
Medical electrical equipment – Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-41:2009 |
Medical electrical equipment - Part 2-41: Particular requirements for basic safety and essential performance of surgical luminaires and luminaires for diagnosis (IEC 60601-2-41:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-41:2009+A1:2015 |
Medical electrical equipment - Part 2-41: Particular requirements for basic safety and essential performance of surgical luminaires and luminaires for diagnosis (IEC 60601-2-41:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-43:2010 |
Medical electrical equipment - Part 2-43: Particular requirements for basic safety and essential performance of X-ray equipment for interventional procedures (IEC 60601-2-43:2010)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-43:2010+A1:2018 |
Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures (IEC 60601-2-43:2010/A1:2017)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-43:2010+A2:2020 |
Medical electrical equipment - Part 2-43: Particular requirements for basic safety and essential performance of X-ray equipment for interventional procedures (IEC 60601-2-43:2010)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-44:2009 |
Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography Clauses 201.17 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-44:2009+A1:2012 |
Medical electricalequipment - Part 2-44: Particular requirements for the basic safetyand essential performance of X-ray equipment for computed tomography (IEC 60601-2-44:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-44:2009+A2:2016 |
Medical electricalequipment - Part 2-44: Particular requirements for the basic safetyand essential performance of X-ray equipment for computed tomography (IEC 60601-2-44:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-45:2011 |
Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-45:2011+A1:2015 |
Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-45:2011+A2:2024 |
Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-49:2015 |
Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-4:2011 |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-4:2011+A1:2019 |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-50:2009 |
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (IEC 60601-2-50:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-50:2009+A11:2011 |
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (IEC 60601-2-50:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-50:2009+A1:2016 |
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (IEC 60601-2-50:2009+A1:2016)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-52:2010 |
Medical electrical equipment - Part 2-52: Particular requirements for basic safety and essential performance of medical beds (IEC 60601-2-52:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-52:2010+A1:2015 |
Medical electrical equipment - Part 2-52: Particular requirements for basic safety and essential performance of medical beds (IEC 60601-2-52:2009+A1:2015)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-52:2010+AC:2011 |
Medical electrical equipment - Part 2-52: Particular requirements for basic safety and essential performance of medical beds (IEC 60601-2-52:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-54:2009 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-54:2009+A1:2015 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy (IEC 60601-2-54:2009+A1:2015)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-54:2009+A2:2019 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy (IEC 60601-2-54:2009/A2:2018)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-57:2011 |
Medical electrical equipment – Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use (IEC 60601-2-57:2011)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-5:2015 |
Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment Clauses 201.17 and 202 Electromagnetic Compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-62:2015 |
Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment (IEC 60601-2-62:2013)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-63:2015 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment (IEC 60601-2-63:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-63:2015+A1:2019 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-63:2015+A2:2021 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-65:2013 |
Medical electrical equipment – Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment (IEC 60601-2-65:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-65:2013+A1:2020 |
Medical electrical equipment – Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment (IEC 60601-2-65:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-65:2013+A2:2021 |
Medical electrical equipment – Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment (IEC 60601-2-65:2012/A2:2021)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-6:2015 |
Medical electrical equipment - Part 2-6: Particular requirements for the basic safety and essential performance of microwave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-6:2015+A1:2016 |
Medical electrical equipment – Part 2-6: Particular requirements for the basic safety and essential performance of microwave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic Disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-6:2015+A2:2024 |
Medical electrical equipment – Part 2-6: Particular requirements for the basic safety and essential performance of microwave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic Disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-8:2015 |
Medical electrical equipment - Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic Xray equipment operating in the range 10 kV to 1 MV (IEC 60601-2-8:2010)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60601-2-8:2015+A1:2016 |
Medical electrical equipment - Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic Xray equipment operating in the range 10 kV to 1 MV (IEC 60601-2-8:2010+A1:2015)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 60945:2002 |
maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results 9: Electomagnetic emission 10: Immunity to electromanetic environment |
CE : 9 kHz ~ 30 MHz RE : 150 MHz ~ 2 GHz ESD : ± 8 kV RS : 80 MHz ~ 2 GHz, 10 V/m EFT : ± 2 kV Surge : ± 1 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61000-3-2:2014 |
Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current <= 16 A per phase) |
≤ 16 A (1 Φ) |
소재지 |
| EN 61000-3-3:2013 |
Electromagnetic compatibility (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection(IEC 61000‒3‒3:2008) |
≤ 16 A (1 Φ) |
소재지 |
| EN 61000-3-3:2013+A1:2019 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection |
≤ 16 A (1 Φ) |
소재지 |
| EN 61000-3-3:2013+A2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection |
≤ 16 A (1 Φ) |
소재지 |
| EN 61000-3-3:2013+A2:2021+AC:2022-01 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection |
≤ 16 A (1 Φ) |
소재지 |
| EN 61000-4-11:2004+A1:2017 |
Electromagnetic compatibility (EMC). Testing and measurement techniques. Voltage dips, short interruptions and voltage variations immunity tests |
≤ 16 A |
소재지 |
| EN 61000-4-16:2016 |
Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
Sweep and continuous : 30 V Short duration test : 300 V |
소재지 |
| EN 61000-4-2:2009 |
Electromagnetic compatibility (EMC). Testing and measurement techniques. Electrostatic discharge immunity test (IEC 61000-4-2:2008) |
± 30 kV |
소재지 |
| EN 61000-4-3:2006+A2:2010 |
Electromagnetic compatibility (EMC). Testing and measurement techniques. Radiated, radio-frequency, electromagnetic field immunity test |
80 MHz ~ 6 GHz |
소재지 |
| EN 61000-4-4:2012 |
Electromagnetic compatibility (EMC). Testing and measurement techniques. Electrical fast transient/burst immunity test(IEC 61000-4-4:2012) |
± (0.2 ~ 4) kV |
소재지 |
| EN 61000-4-5:2014+A1:2017 |
Electromagnetic compatibility (EMC). Testing and measurement techniques. Surge immunity test |
± (0.5 ~ 15) kV |
소재지 |
| EN 61000-4-6:2014 |
Electromagnetic compatibility (EMC). Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields |
150 kHz ~ 1 GHz |
소재지 |
| EN 61000-4-6:2014+AC:2015 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
150 kHz ~ 1 GHz |
소재지 |
| EN 61000-4-8:2010 |
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
300 A / Continous 1 200 A / Short |
소재지 |
| EN 61000-4-9:2016 |
Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test |
(100 ~ 1 000) A/m (Peak) |
소재지 |
| EN 61000-6-1:2007 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61000-6-2:2005+AC:2005 |
Electromagnetic compatibility (EMC). Generic standards. Immunity for industrial environments |
ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61000-6-3:2007+A1:2011+AC:2012 |
Electromagnetic compatibility (EMC). Generic standards. Emission standard for residential, commercial and light-industrial environments |
CE : 150 kHz ~ 30 MHz RE : 30 kHz ~ 6 GHz Harmonic/Flicker : ≤ 16 A (1 Φ) |
소재지 |
| EN 61000-6-4:2007+A1:2011 |
Electromagnetic compatibility (EMC). Generic standards. Emission standard for industrial environments |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz |
소재지 |
| EN 61326-1:2013 |
Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61326-2-1:2013 |
Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61326-2-2:2013 |
Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61326-2-3:2013 |
Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61326-2-4:2013 |
Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61326-2-5:2013 |
Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configurations, operational conditions and performance criteria for devices with field bus interfaces according to IEC 61784-1 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61326-2-6:2013 |
Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. In vitro diagnostic (IVD) medical equipment |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 61547:2009 |
Equipment for general lighting purposes. EMC immunity requirements |
ESD : ± 8 kV RS : 80 MHz ~ 1 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 80601-2-35:2009+A1:2016 |
Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads and mattresses and intended for heating in medical use Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN 80601-2-60:2015 |
Medical electrical equipment – Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment (IEC 80601-2-60:2012)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 55014-1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE : 9 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 9 kHz ~ 6 GHz |
소재지 |
| EN IEC 55014-2:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 55015:2019 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) Loop diameter (3 m and 4 m) of Table 7 and 8 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 1 000 MHz |
소재지 |
| EN IEC 55015:2019+A11:2020 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
(Exception) Loop diameter (3 m and 4 m) of Table 7 and 8 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 1 000 MHz |
소재지 |
| EN IEC 60601-2-16:2019 |
Medical electrical equipment – Part 2-16: Particular requirements for the basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment (IEC 60601-2-16:2018)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-19:2021 |
Medical electrical equipment – Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-19:2021+A1:2023 |
Medical electrical equipment – Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-20:2020 |
Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (IEC 60601-2-20:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-20:2020+A1:2023 |
Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (IEC 60601-2-20:2009)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-21:2021 |
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-21:2021+A1:2023 |
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-22:2020 |
Medical electrical equipment – Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment (IEC 60601-2-22:2019)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-28:2019 |
Medical electrical equipment Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-2:2018 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic Disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-2:2018+A1:2024 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic Disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-31:2020 |
Medical electricalequipment - Part2-31:Particular requirementsfor the basicsafety and essential performance ofexternal cardiac pacemakers with internalpowersource (IEC 60601-2-31:2008)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-41:2021 |
Medical electrical equipment - Part 2-41: Particular requirements for basic safety and essential performance of surgical luminaires and luminaires for diagnosis
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-46:2019 |
Medical electrical equipment – Part 2-46: Particular requirements for the basic safety and essential performance of operating tables (IEC 60601-2-46:2010)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-46:2024 |
Medical electrical equipment – Part 2-46: Particular requirements for the basic safety and essential performance of operating tables (IEC 60601-2-46:2010)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-50:2021 |
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 60601-2-50:2021+A1:2023 |
Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61000-3-2:2019 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
≤ 16 A (1 Φ) |
소재지 |
| EN IEC 61000-3-2:2019+A1:2021 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
≤ 16 A (1 Φ) |
소재지 |
| EN IEC 61000-3-2:2019+A2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
≤ 16 A (1 Φ) |
소재지 |
| EN IEC 61000-4-11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
≤ 16 A |
소재지 |
| EN IEC 61000-4-11:2020+AC:2020-06 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
≤ 16 A |
소재지 |
| EN IEC 61000-4-11:2020+AC:2022-10 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
≤ 16 A |
소재지 |
| EN IEC 61000-4-3:2020 |
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
80 MHz ~ 6 GHz |
소재지 |
| EN IEC 61000-6-1:2019 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61000-6-2:2019 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61000-6-3:2021 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
CE : 150 kHz ~ 30 MHz RE : 30 kHz ~ 6 GHz Harmonic/Flicker : ≤ 16 A (1 Φ) |
소재지 |
| EN IEC 61000-6-4:2019 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz |
소재지 |
| EN IEC 61204-3:2018 |
Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
CE : 150 kHz ~ 30 MHz RE : 9 kHz ~ 1 GHz ESD : ± 8 kV RS : 80 MHz ~ 1 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61326-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61326-2-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61326-2-2:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61326-2-3:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61326-2-4:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61326-2-5:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784-1 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 61326-2-6:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 62040-2:2018 |
Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100) % Harmonic : ≤16 A (1Φ) Flicker : ≤16 A (1Φ) |
소재지 |
| EN IEC 80601-2-30:2019 |
Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers (IEC 80601-2-30:2018)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 80601-2-59:2019 |
Medical electrical equipment - Part 2-59: Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening (IEC 80601-2-59:2017+AMD1:2023)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 80601-2-59:2019+A1:2023 |
Medical electrical equipment - Part 2-59: Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening (IEC 80601-2-59:2017+AMD1:2023)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN IEC 80601-2-60:2020 |
Medical electrical equipment – Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment (IEC 80601-2-60:2019)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| EN ISO 80601-2-55:2018 |
Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors (ISO 80601-2-55:2018)
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ETSI EN 300 386 V2.2.1:2022 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); Telecommunication network equipment: ElectroMagnetic Compatibility (EMC) requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| ETSI EN 301 489-1 V2.2.3:2019 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility
(Exception) 9.6 Transient and surges in the vehicular environment |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % Harmonic : ≤ 16 A (1Φ) Flicker ≤ 16 A (1Φ) |
소재지 |
| ETSI EN 301 489-12 V3.2.1:2021 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 12: Specific conditions for Very Small Aperture Terminal, Satellite Interactive Earth Stations operated in the frequency ranges between 4 GHz and 30 GHz in the Fixed Satellite Service (FSS) |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| ETSI EN 301 489-17 V3.3.1:2024 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: specific conditions for Broadband Data Transmission Systems; Harmonised Standard for ElectroMagnetic Compatibility
(Exception) 9.6 Transient and surges in the vehicular environment |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % Harmonic : ≤16 A (1Φ) Flicker : ≤16 A (1Φ) |
소재지 |
| ETSI EN 301 489-19 V2.2.1:2022 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band (ROGNSS) providing positioning, navigation, and timing data |
RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| ETSI EN 301 489-3 V2.3.2:2023 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility(EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz
(Exception) 9.6 Transient and surges in the vehicular environment |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % Harmonic : ≤16 A (1Φ) Flicker : ≤16 A (1Φ) Exemption : ISO 7637-2 제외 |
소재지 |
| ETSI EN 301 489-34 V2.1.1:2019 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility(EMC) standard for radio equipment and services; Part 34: Specific conditions for External Power Supply (EPS) for mobile phone.
(Exception) 9.6 Transient and surges in the vehicular environment |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % Harmonic : ≤16 A (1Φ) Flicker : ≤16 A (1Φ) |
소재지 |
| FCC CFR47 Part 15 Subpart B:2023 |
Radio Frequency Device
(Exception) 15.31 Noise Figure 15.115 TV interface devices, including cable system terminal devices. 15.117 TV broadcast receivers. |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| FCC CFR47 Part 18:2023 |
Industrial, Scientific, and Medical Equipment |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| IACS UR E10 Rev.9:2023 |
Test Specification for Type Approval |
CE : 10 kHz ~ 30 MHz RE : 150 kHz ~ 6 GHz ESD : 8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : 2 kV SURGE: 1 kV CLS : 10 %, 2 W CS : 3 V, 150 kHz ~ 80 MHz Voltage Variation : V ±20 % Variation (1.5 s) F ±10 % Variation (5 s) V 100% dip (300 s) |
소재지 |
| ICES-001 Issue5:2020 |
Industrial, Scientific and Medical (ISM) Radio Frequency Generators |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| ICES-003 Issue7:2020 |
Information Technology Equipment (ITE) – Limits and Methods of Measurement |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| IEC 60092-504:2016 |
Electrical installations in ships - Part 504 : Automation, control and instrumentation |
CE : 10 kHz ~ 30 MHz RE : 150 kHz ~ 6 GHz ESD : ± 8 kV RS : 10 V/m, 80 MHz ~ 6 GHz EFT : ± 2 kV SURGE: ± 1 kV CLS : 10 %, 2 W CS : 3 V, 150 kHz ~ 80 MHz Voltage Variation : V ±20 % Variation (1.5 s) F ±10 % Variation (5 s) V 100% dip (300 s) |
소재지 |
| IEC 60533:2015 |
Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
CE : 10 kHz ~ 30 MHz RE : 150 kHz ~ 2 GHz ESD : 8 kV RS : 10 V/m, 80 MHz ~ 2 GHz EFT : ± 2 kV SURGE : ± 1 kV CLS : 10 %, 2 W CS : 3 V, 150 kHz ~ 80 MHz Voltage Variation : V ±20 % Variation (1.5 s) F ±10 % Variation (5 s) V 100 % Dip (60 s) |
소재지 |
| IEC 60571:2012 |
Railway applications – Electronic equipment used on rolling stock
12.2.7 Supply overvoltage 12.2.8 Surges, ESD and transient burst susceptibility tests 12.2.9 Radio frequency test |
CE : 150 kHz ~ 30 MHz RE : 9 kHz ~ 1 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz |
소재지 |
| IEC 60601-1-11:2015 |
Medical electrical equipment – Part 1-11: General requirements for basic safety and essential performance – Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
- 12 Additional requirements for ELECTROMAGNETIC EMISSIONS of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| IEC 60601-1-11:2015+A1:2020 |
Medical electrical equipment – Part 1-11: General requirements for basic safety and essential performance – Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
- 12 Additional requirements for ELECTROMAGNETIC EMISSIONS of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| IEC 60601-1-2:2007 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 5 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-1-2:2014 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-1-2:2014+A1:2020 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbance - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-10:2012 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-10:2012+A1:2016 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-10:2012+A1:2016+A2:2023 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-16:2018 |
Medical electrical equipment – Part 2-16: Particular requirements for the basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-18:2009 |
Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-19:2009 |
Medical electrical equipment – Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-19:2009+A1:2016 |
Medical electrical equipment – Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-19:2020 |
Medical electrical equipment – Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-19:2020+A1:2023 |
Medical electrical equipment – Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-20:2009+A1:2016 |
Medical electrical equipment – Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-20:2020 |
Medical electrical equipment – Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-20:2020+A1:2023 |
Medical electrical equipment – Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-21:2009+A1:2016 |
Medical electrical equipment – Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-21:2020 |
Medical electrical equipment – Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-21:2020+A1:2023 |
Medical electrical equipment – Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-22:2007 |
Medical electrical equipment – Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-22:2007+A1:2012 |
Medical electrical equipment – Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-22:2019 |
Medical electrical equipment – Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-24:1998 |
Medical electrical equipment - Part 2-24: Particular requirements for the safety of infusion pumps and controllers
- 36 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-24:2012 |
Medical electrical equipment – Part 2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-25:2011 |
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety and essential performance of electrocardiographs Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-26:2012 |
Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-27:2011 |
Medical electrical equipment Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-28:2010 |
Medical electrical equipment Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis Clauses 201.17 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-28:2017 |
Medical electrical equipment Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis Clauses 201.17 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-2:2009 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-2:2017 |
Medical electrical equipment -Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-2:2017+A1:2023 |
Medical electrical equipment -Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-31:2020 |
Medical electrical equipment – Part 2-31: Particular requirements for the basic safety and essential performance of external cardiac pacemakers with internal power source
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-34:2011 |
Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-34:2024 |
Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-35:2020 |
Medical electrical equipment Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads or mattresses and intended for heating in medical use
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-35:2020+A1:2023 |
Medical electrical equipment Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads or mattresses and intended for heating in medical use
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-37:2007 |
Medical electrical equipment - Part 2-37: Particular requirements for the safety and essential performance of ultrasonic medical diagnostic and monitoring equipment Clauses 201.17 and 202.6 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-37:2007+A1:2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the safety and essential performance of ultrasonic medical diagnostic and monitoring equipment Clauses 201.17 and 202.6 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-3:2012 |
Medical electrical equipment – Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-3:2012+A1:2016 |
Medical electrical equipment – Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-3:2012+A1:2016+A2:2022 |
Medical electrical equipment - Part 2-3: Particular requirements for the basic safety and essential performance of short-wave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-41:2009+A1:2013 |
Medical electrical equipment – Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-41:2021 |
Medical electrical equipment - Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-43:2010 |
Medical electrical equipment – Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-43:2010+A1:2017 |
Medical electrical equipment – Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-43:2010+A1:2017+A2:2019 |
Medical electrical equipment – Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-43:2022 |
Medical electrical equipment – Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-44:2009+A1:2012 |
Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography Clauses 201.17 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-44:2009+A1:2012+A2:2016 |
Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-45:2011 |
Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-45:2011+A1:2015 |
Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-45:2011+A1:2015+A2:2022 |
Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-46:2016 |
Medical electrical equipment – Part 2-46: Particular requirements for the basic safety and essential performance of operating tables
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-46:2023 |
Medical electrical equipment – Part 2-46: Particular requirements for the basic safety and essential performance of operating tables
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-49:2011 |
Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-4:2010 |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators Clauses 202.17 and 202 Electromagnetic Compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-4:2010+A1:2018 |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators Clauses 201.17 and 202 Electromagnetic Compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-50:2009+A1:2016 |
Medical electrical equipment – Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-50:2020 |
Medical electrical equipment – Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-50:2020+A1:2023 |
Medical electrical equipment – Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-52:2009+A1:2015 |
Medical electrical equipment – Part 2-52: Particular requirements for the basic safety and essential performance of medical beds
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-54:2009 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-54:2009+A1:2015 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-54:2009+A1:2015+A2:2018 |
Medical electrical equipment – Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-54:2022 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-57:2011 |
Medical electrical equipment – Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-57:2023 |
Medical electrical equipment – Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-5:2009 |
Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment Clauses 201.17 and 202 Electromagnetic Compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-62:2013 |
Medical electrical equipment – Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-63:2012 |
Medical electrical equipment - Part 2-63: Particular requirements for basic safety and essential performance of dental extra-oral X-ray equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-63:2012+A1:2017 |
Medical electrical equipment – Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-63:2012+A1:2017+A2:2021 |
Medical electrical equipment – Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-65:2012 |
Medical electrical equipment – Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-65:2012+A1:2017 |
Medical electrical equipment – Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-65:2012+A1:2017+A2:2021 |
Medical electrical equipment – Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-6:2012+A1:2016 |
Medical electrical equipment – Part 2-6: Particular requirements for the basic safety and essential performance of microwave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic Disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-6:2012+A1:2016+A2:2022 |
Medical electrical equipment - Part 2-6: Particular requirements for the basic safety and essential performance of microwave therapy equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic Disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-8:2010 |
Medical electrical equipment – Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60601-2-8:2010+A1:2015 |
Medical electrical equipment – Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV
- 201.17 Electromagnetic compatibility of ME |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 60945:2002 |
Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results |
CE : 10 kHz ~ 30 MHz RE : 150 MHz ~ 2 GHz ESD : ± 8 kV RS : 80 MHz ~ 2 GHz, 10 V/m EFT : ± 2 kV Surge : ± 1 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100 ) % Voltage Variation : V ±20 % Variation (1.5 s) F ±10 % Variation (5 s) V 100% dip (300 s) |
소재지 |
| IEC 61000-3-2:2018 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
≤ 16 A (1 Φ) |
소재지 |
| IEC 61000-3-2:2018+A1:2020 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
≤ 16 A (1 Φ) |
소재지 |
| IEC 61000-3-2:2018+A2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
≤ 16 A (1 Φ) |
소재지 |
| IEC 61000-3-3:2013+A1:2017 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
≤ 16 A (1 Φ) |
소재지 |
| IEC 61000-3-3:2013+A1:2017+A2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
≤ 16 A (1 Φ) |
소재지 |
| IEC 61000-4-11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
≤ 16 A |
소재지 |
| IEC 61000-4-16:2015 |
Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz |
Sweep and continuous : 30 V Short duration test : 300 V |
소재지 |
| IEC 61000-4-2:2008 |
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
± 30 kV |
소재지 |
| IEC 61000-4-3:2020 |
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
80 MHz ~ 6 GHz |
소재지 |
| IEC 61000-4-4:2012 |
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
± (0.2 ~ 4) kV |
소재지 |
| IEC 61000-4-5:2014+A1:2017 |
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test |
± (0.5 ~ 15) kV |
소재지 |
| IEC 61000-4-6:2013 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
150 kHz ~ 1 GHz |
소재지 |
| IEC 61000-4-6:2023 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
150 kHz ~ 1 GHz |
소재지 |
| IEC 61000-4-8:2009 |
Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
300 A / Continous 1 200 A / Short |
소재지 |
| IEC 61000-4-9:2016 |
Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test |
(100 ~ 1 000) A/m (Peak) |
소재지 |
| IEC 61000-6-1:2016 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61000-6-2:2016 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments |
ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61000-6-3:2020 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
CE : 150 kHz ~ 30 MHz RE : 30 kHz ~ 6 GHz Harmonic/Flicker : ≤ 16 A (1 Φ) |
소재지 |
| IEC 61000-6-4:2018 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz |
소재지 |
| IEC 61204-3:2016 |
Low voltage power supplies, d.c.output - Part 3: Electromagnetic compatibility (EMC) |
CE : 150 kHz ~ 30 MHz RE : 9 kHz ~ 1 GHz ESD : ± 8 kV RS : 80 MHz ~ 1 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61326-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61326-2-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61326-2-2:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61326-2-3:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61326-2-4:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61326-2-5:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784-1 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61326-2-6:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 61547:2020 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD : ± 8 kV RS : 80 MHz ~ 1 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 62040-2:2016 |
Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100 ) % Harmonic : ≤16 A (1Φ) Flicker : ≤16 A (1Φ) |
소재지 |
| IEC 62236-1:2018 |
Railway Application - Electromagnetic Compatibility - Part 1: General |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz EFT : ± 4 kV Surge : ± 4 kV CS : 150 kHz ~ 230 MHz MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 62236-2:2018 |
Railway Application - Electromagnetic Compatibility - Part 2: Emission of the whole railway system to the outside world |
RE : 9 kHz ~ 1 GHz |
소재지 |
| IEC 62236-3-2:2018 |
Railway Application - Electromagnetic Compatibility - Part 3 - 2 Rolling Stock _ Apparatus |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 10 V |
소재지 |
| IEC 62236-4:2018 |
Emission and immunity of the signalling and telecommunications apparatus |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 10 V MF : 300 A/m Pulse Magnetic : 300 A/m |
소재지 |
| IEC 62236-5:2018 |
Railway Application - Electromagnetic Compatibility Fixed power supply installations
(Exception) Table3. Damped Oscillatory Voltage |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 4 kV Surge : ± 4 kV CS : 150 kHz ~ 230 MHz, 10 V MF : 300 A/m |
소재지 |
| IEC 80601-2-30:2009+A1:2013 |
Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 80601-2-30:2018 |
Medical electrical equipment – Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 80601-2-35:2009+A1:2016 |
Medical electrical equipment Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads or mattresses and intended for heating in medical use
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 80601-2-59:2017 |
Medical electrical equipment – Part 2-59: Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 80601-2-59:2017+A1:2023 |
Medical electrical equipment – Part 2-59: Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 80601-2-60:2012 |
Medical electrical equipment – Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| IEC 80601-2-60:2019 |
Medical electrical equipment – Part 2-60: Particular requirements for the basic safety and essential performance of dental equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ISO 80601-2-55:2011 |
Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic compatibility - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ISO 80601-2-55:2018 |
Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ISO 80601-2-56:2017 |
Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ISO 80601-2-56:2017+A1:2018 |
Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Electromagnetic disturbances - Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ISO 80601-2-61:2011 |
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ISO 80601-2-61:2017 |
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment Clauses 201.17 and 202 Electromagnetic compatibility |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| ISO 80601-2-67:2020 |
Medical electrical equipment — Part 2-67: Particular requirements for basic safety and essential performance of oxygen conserving equipment
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS - 202 Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral standard: Electromagnetic disturbances – Requirements and tests |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 5.8 GHz, 28 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 6 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| J 55014-1(H27):2011 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
CE : 150 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 30 MHz ~ 1 000 MHz |
소재지 |
| J 55015(H29):2017 |
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Appliances, electric tools and similar apparatus - Part 1: Emission
(Exception) 7. Insertion Loss Loop diameter (3 m and 4 m) of Table 3a |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 300 MHz |
소재지 |
| J 55032(H29):2017 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz Conducted Differential Voltage Emission(VE) : 30 MHz ~ 2 150 MHz |
소재지 |
| KR:2024 |
한국선급 : 제조법 및 형식승인 등에 관한 지침 제 3장 형식승인
제23절 자동화시스템 표 3.23.1의 3 전원상실시험 , 4 전원변동시험 , 14 정전기방전내성시험 , 15 방사전자계내성시험 , 16 전도성 저주파 간섭에 대한 내성시험, 17 전도성 고주파 간섭에 대한 내성시험 , 18 전기적 패스트 트랜젠트 / 버스트 내성시험 , 19 서지 내성시험 , 20 발산방사 측정시험 , 21 전도방사측정시험
제31절 LED 조명기구 표 3.31.1 3 전원상실시험 , 4 전원변동시험 , 11 전자파 적합성시험 (No. 14~21) |
CE: 10 kHz ~ 30 MHz RE: 150 kHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz EFT : ± 2 kV SURGE: ± 1 kV CLS : 10 %, 2 W CS : 3 V, 150 kHz ~ 80 MHz Voltage Variation : V ±20 % Variation (1.5 s) F ±10 % Variation (5 s) V 100% dip (300 s) |
소재지 |
| KS B 6945:2019 |
전자기 적합성 - 엘리베이터, 에스컬레이터 및 무빙워크 제품군 표준 - 내성 |
ESD : ± 15 kV RS : 80 MHz ~ 2.675 GHz, 30 V/m EFT : ± 4 kV Surge : ± 2.5 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100 ) % |
소재지 |
| KS B 6955:2019 |
전자기 적합성 - 엘리베이터, 에스컬레이터 및 무빙워크 제품군 표준 - 방사 |
CE : 150 kHz ~ 30 MHz RE : 30 kHz ~ 1 GHz |
소재지 |
| KS C 9040-2:2017 |
무정전전원장치(UPS) - 제2부 : 전자파적합성(EMC) 요구사항 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V V-dip : (0 ~ 100 ) % Harmonic : ≤16 A (1Φ) Flicker : ≤16 A (1Φ) |
소재지 |
| KS C 9547:2020 |
일반 조명기기 - 전자파적합성(EMC) 내성 요구사항 |
ESD : ± 8 kV RS : 80 MHz ~ 1 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| KS C 9610-4-11:2020 |
전자파적합성(EMC)-제4-11부: 시험 및 측정 기술-전압 강하, 순간 정전, 전압 변동 내성 시험 |
≤ 16 A |
소재지 |
| KS C 9610-4-2:2017 |
전자파적합성(EMC)-제4-2부:시험 및 측정기술-정전기 방전 내성시험 |
± 30 kV |
소재지 |
| KS C 9610-4-3:2017 |
전자파적합성(EMC)-제4-3부:시험 및 측정 기술-방사성 RF 전자기장 내성 시험 |
20 MHz ~ 6 GHz |
소재지 |
| KS C 9610-4-4:2020 |
전자파적합성(EMC)-제4-4부:시험 및 측정 기술-전기적 빠른 과도현상, 버스트 내성 시험 |
± (0.2 ~ 4) kV |
소재지 |
| KS C 9610-4-5:2023 |
전자파적합성(EMC) - 제4-5부: 시험 및 측정 기술 - 서지 내성 시험 |
± (0.5 ~ 15) kV |
소재지 |
| KS C 9610-4-6:2020 |
전자파적합성(EMC)-제4-6부:시험 및 측정 기술-전도성 RF 전자기장 내성 시험 |
150 kHz ~ 1 GHz |
소재지 |
| KS C 9610-4-8:2017 |
전자파적합성(EMC)-제4-8부:시험 및 측정기술-전원 주파수 자기장 내성 시험 |
300 A / Continous 1 200 A / Short |
소재지 |
| KS C 9610-4-9:2019 |
전자파적합성(EMC)-제4-9부: 시험 및 측정 기술-임펄스 자기장 내성 시험 |
(100 ~ 1 000) A/m (Peak) |
소재지 |
| KS C 9610-6-1:2019 |
전자파적합성(EMC) - 제6-1부: 일반표준 - 주거, 상업 및 경공업 환경에서 사용하는 기기의 전자파 내성 표준 |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V MF : 3 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| KS C 9610-6-2:2019 |
전자파적합성(EMC) - 제6-2부 : 일반표준 - 산업 환경에서 사용하는 기기의 전자파 내성 표준 |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 10 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| KS C 9610-6-3:2023 |
전자파적합성(EMC) - 제6-3부: 일반기준 - 산업 환경에서 사용하는 기기의 전자파 방해 표준 |
CE : 150 kHz ~ 30 MHz RE : 30 kHz ~ 6 GHz |
소재지 |
| KS C 9610-6-4:2022 |
전자파적합성(EMC) - 제6-4부 : 일반표준 - 산업 환경에서 전자파 방출 표준 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz |
소재지 |
| KS C 9811:2019 |
산업, 과학, 의료용(ISM) 기기-무선 주파수 방해 특성-허용기준 및 측정 방법 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz |
소재지 |
| KS C 9814-1:2022 |
전자파적합성(EMC) - 가정용 전기기기, 전동 공구 및 유사기기의 요구사항-제1부: 방출 |
CE : 9 kHz ~ 30 MHz DP : 30 MHz ~ 300 MHz RE : 9 kHz ~ 6 GHz |
소재지 |
| KS C 9814-2:2022 |
전자파적합성(EMC) - 가정용 전기기기, 전동 공구 및 유사기기의 요구사항- 제2부:내성 |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| KS C 9815:2023 |
조명 기기 및 유사 기기의 무선 방해 특성 측정 허용기준과 측정 방법
(제외항목) 표7, 표8에서 루프 직경 3 m와 4 m |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 1 000 MHz |
소재지 |
| KS C 9816-2-1:2023 |
전자파 방해 및 내성 측정장비와 측정방법-제2-1부:전자파 방해 및 내성 측정방법-전도성 방해 측정 |
CE: 9 kHz ~ 30 MHz |
소재지 |
| KS C 9816-2-2:2020 |
전자파 방해 및 내성 측정장비와 측정방법-제2-2부:전자파 방해 및 내성 측정방법-방해전력 측정 |
DP: 30 MHz ~ 300 MHz |
소재지 |
| KS C 9816-2-3:2020 |
전자파 방해 및 내성 측정장비와 측정방법-제2-3부:전자파 방해 및 내성 측정방법-방사성 방해 측정 |
RE : 9 kHz ~ 18 GHz |
소재지 |
| KS C 9816-2-4:2017 |
전자파 방해 및 내성 측정장비와 측정방법-제2-4부:전자파 방해 및 내성 측정방법-내성 측정 |
RS : 80 MHz ~ 3 GHz CS : 150 kHz ~ 230 MHz |
소재지 |
| KS C 9832:2024 |
멀티미디어 기기 전자파 방해 시험방법 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz Conducted Differential Voltage Emission(VE) : 30 MHz ~ 2 150 MHz |
소재지 |
| KS C 9835:2019 |
멀티미디어 기기 전자파 내성 시험방법 |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 10 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V MF : 1 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| KS C IEC 60571:2012 |
철도 적용 - 철도 차량용 전자기기
12.2.8 서지, 정전기 방전 및 과도 버스트 민감성 시험 12.2.9 무선 주파수 시험 |
CE : 150 kHz ~ 30 MHz RE : 9 kHz ~ 1 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz |
소재지 |
| KS C IEC 60601-1-2:2020 |
의료용 전기기기 - 제1-2부: 기본 안전 및 필수 성능에 관한 일반 요구사항 |
CE : 9 kHz ~ 30 MHz RE : 9 kHz ~ 18 GHz ESD : ± 15 kV RS : 80 MHz ~ 2.7 GHz, 10 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 3 V MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| KS C IEC 62236-1:2018 |
철도 적용 - 전자기 적합성 - 제1부: 일반사항 |
ESD : ± 8 kV RS : 80 MHz ~ 6 GHz EFT : ± 4 kV Surge : ± 4 kV CS : 150 kHz ~ 230 MHz MF : 30 A/m V-dip : (0 ~ 100 ) % |
소재지 |
| KS C IEC 62236-2:2018 |
철도 적용 - 전자기 적합성 - 제2부: 전체 철도 시스템에서 외부로 나가는 방출 |
RE : 9 kHz ~ 1 GHz |
소재지 |
| KS C IEC 62236-3-2:2018 |
철도 적용 - 전자기 적합성 - 제3-2부: 철도 차량 - 기기 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 10 V |
소재지 |
| KS C IEC 62236-4:2018 |
철도 적용 - 전자기 적합성 - 제4부: 신호 및 통신 기기의 방출 및 내성 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 2 kV Surge : ± 2 kV CS : 150 kHz ~ 230 MHz, 10 V MF : 300 A/m Pulse Magnetic : 300 A/m |
소재지 |
| KS C IEC 62236-5:2018 |
철도 적용 - 전자기 적합성 - 제5부: 고정 전력공급 설비와 기기의 방출 및 내성
(제외항목) 표3. 감쇠 발진 전압 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 20 V/m EFT : ± 4 kV Surge : ± 4 kV CS : 150 kHz ~ 230 MHz, 10 V MF : 300 A/m |
소재지 |
| KS X 3124:2020 |
무선기기의 공통 전자파적합성 시험방법
(제외항목) 9.6 차량 환경에서의 과도현상 및 서지 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| KS X 3125:2020 |
특정 소출력 무선기기 전자파적합성 시험방법
(제외항목) 9.6 차량 환경에서의 과도현상 및 서지 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| KS X 3126:2020 |
무선 데이터 통신 시스템용 특정 소출력 무선기기 전자파적합성 시험방법
(제외항목) 9.6 차량 환경에서의 과도현상 및 서지 |
CE : 150 kHz ~ 30 MHz RE : 30 MHz ~ 6 GHz ESD : ± 8 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ± 1 kV Surge : ± 2 kV CS : 150 kHz ~ 80 MHz, 3 V V-dip : (0 ~ 100 ) % |
소재지 |
| S2-W-5:2024 |
기계.기구 등에 관한 공통 기술기준 [전자파분야]
전자파 적합성에 관한 기술기준 |
CE: 9 kHz ~ 30 MHz RE: 9 kHz ~ 18 GHz ESD : ± 30 kV RS : 80 MHz ~ 6 GHz EFT : ± 4 kV SURGE: ± 4 kV CS : 150 kHz ~ 1 GHz V-Dip : (0 ~ 100) % |
소재지 |