| ▶ 유/무선 통신기기 |
| ETSI EN 303 345-1 V1.1.1:2019 |
Broadcast Sound Receivers; Part 1: Generic requirements and measuring methods |
Signal system: AM, FM, DAB, DRM |
소재지 |
| ETSI EN 303 345-2 V1.2.1:2021 |
Broadcast Sound Receivers; Part 2: AM broadcast sound service; Harmonised Standard for access to radio spectrum |
Signal system: AM |
소재지 |
| ETSI EN 303 345-3 V1.1.1:2021 |
Broadcast Sound Receivers; Part 3: FM broadcast sound service; Harmonised Standard for access to radio spectrum |
Signal system: FM |
소재지 |
| ETSI EN 303 345-4 V1.1.1:2021 |
Broadcast Sound Receivers; Part 4: DAB broadcast sound service; Harmonised Standard for access to radio spectrum |
Signal system: DAB |
소재지 |
| ETSI EN 303 345-5 V1.2.1:2021 |
Broadcast Sound Receivers; Part 5: DRM broadcast sound service; Harmonised Standard for access to radio spectrum |
Signal system: DRM |
소재지 |
| KS X 3123:2022 |
무선 설비 적합성 평가 시험방법
(Exception) 부속서A. 환경적 조건의 구분 표A.1. 진동 시험 조건의 구분 표A.2. 충격 시험 조건의 구분 표A.3. 연속 동작 시험 조건의 구분 표A.6. 낙하 시험 조건 표A.7. 수밀 시험 조건 표A.8. 주수 시험 조건 표A.9. 기압 시험 조건
부속서C. 적합성 평가 항목별 시험방법 C.9. 반송파 전력비 측정 방법(SSB) C.10. 종합 왜율 및 잡음 측정 방법 C.11. 프리엠파시스 측정 방법 C.15. 출력 제어 기능 측정 방법 C.19. 반송파 감지 장치 측정 방법 C.21. 감도 측정 방법 C.22. 감도 억압 효과 측정 방법 C.23. 디엠파시스 측정 방법 C.25. 종합 주파수 특성 측정 방법
부속서 J. 전파법 시행령 제25조 제4호에 따른 무선설비 중 20 GHz이상의 주파수를 사용하는 무선설비의 적합성 평가 항목별 복사시험방법 부속서 K. 체내이식용 무선설비의 적합성 평가 시험방법 부속서 M. 지능형교통시스템용 무선설비의 적합성평가 항목별 시험방법 부속서 N. 레벨측정레이다용 무선기기 적합성평가 시험방법 부속서 O. UWB용 무선기기의 적합성평가 항목별 시험방법 |
시험주파수: 9 kHz ~ 26.5 GHz 주파수 분해능: 0.01 Hz 분해능 대역폭: 10 Hz to 10 MHz 최대 입력 수준: 1 W // DC 0 V (Internal attenuator) 검출모드: Peak, RMS |
소재지 |
| EN 62479:2010 |
Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
Test Frequency: 10 MHz ~ 18 GHz |
소재지 |
| EN IEC 62311:2020 |
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz) |
Test Frequency: 0 Hz ∼ 6 GHz |
소재지 |
| ETSI EN 300 220-1 V3.1.1:2017 |
Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 1:Technical characteristics and methods of measurement |
Test Frequency: 9 kHz ~ 6 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 220-2 V3.2.1:2018 |
Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 2:Harmonised Standard for access to radio spectrum for non specific radio equipment |
Test Frequency: 9 kHz ~ 6 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 220-3-1 V2.1.1:2016 |
Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 3-1:Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU; Low duty cycle high reliability equipment, social alarms equipment operating on designated frequencies (869,200 MHz to 869,250 MHz) |
Test Frequency: 9 kHz ~ 6 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 220-3-2 V1.1.1:2017 |
Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 3-2:Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU; Wireless alarms operating in designated LDC/HR frequency bands 868,60 MHz to 868,70 MHz, 869,25 MHz to 869,40 MHz, 869,65 MHz to 869,70 MHz |
Test Frequency: 9 kHz ~ 6 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 220-4 V1.1.1:2017 |
Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 4:Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU; Metering devices operating in designated band 169,400 MHz to 169,475 MHz |
Test Frequency: 9 kHz ~ 6 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 330 V2.1.1:2017 |
Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
Test Frequency: 9 kHz ~ 1 000 MHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 440 V2.1.1:2017 |
Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
(Exception) Carrier frequencies above 20 GHz |
Test Frequency: 25 MHz ~ 40 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 440 V2.2.1:2018 |
Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Harmonised Standard for access to radio spectrum
(Exception) Carrier frequencies above 20 GHz |
Test Frequency: 25 MHz ~ 40 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 300 328 V2.2.2:2019 |
Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum |
Test Frequency: 30 MHz ~ 12.75 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 301 893 V2.1.1:2017 |
5 GHz RLAN; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
Test Frequency: 30 MHz ~ 26 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 301 893 V2.2.1:2024 |
5 GHz WAS/RLAN; Harmonised Standard for access to radio spectrum |
Test Frequency: 30 MHz ~ 26 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
ETSI EN 303 417 V1.1.1 : 2017 |
Wireless power transmission systems, using technologies other than radio frequency beam, in the 19 - 21 kHz, 59 - 61 kHz, 79 - 90 kHz, 100 - 300 kHz, 6 765 - 6 795 kHz ranges; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
Test Frequency: 9 kHz ~ 1 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ETSI EN 303 340 V1.1.2:2016 |
Digital Terrestrial TV Broadcast Receivers; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
Signal system: DVB-T/T2 |
소재지 |
| ETSI EN 303 340 V1.2.1:2020 |
Digital Terrestrial TV Broadcast Receivers; Harmonised Standard for access to radio spectrum |
Signal system: DVB-T/T2 |
소재지 |
| ETSI EN 303 372-2 V1.2.1:2021 |
Satellite Earth Stations and Systems (SES); Satellite broadcast reception equipment; Part 2: Indoor unit; Harmonised Standard for access to radio spectrum |
Signal system: DVB-S/S2 |
소재지 |
| AS/NZS 4268:2017 |
Radio equipment and systems - Short range devices - Limits and methods of measurement |
Test Frequency: 9 kHz ~ 26.5 GHz Frequency resolution: 0.01 Hz Resolution bandwidth: 10 Hz to 10 MHz Max. input: 1 W // DC 0 V (Internal attenuator) Detect mode: Peak, sample, average, RMS, Quasi Peak Sweep point: 101 to 32 001 |
소재지 |
| ▶ 전자기적합성 |
| IEC 60601-1-2:2014/AMD1:2020 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN IEC 61326-2-6:2021 |
Electrical equipment for measurement, control and laboratory use – EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| IEC 61326-2-6:2020 |
Electrical equipment for measurement, control and laboratory use – EMC requirements - Part 2-6: Particular requirements – In vitro diagnostic (IVD) medical equipment |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN IEC 61326-2-5:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784-1 |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| IEC 61326-2-5:2020 |
Electrical equipment for measurement, control and laboratory use – EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784-1 |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN IEC 61326-2-4:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| IEC 61326-2-4:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN IEC 61326-2-3:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| IEC 61326-2-3:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements – Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN 60601-1-2:2015 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN 60601-1-2:2015/A1:2021 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN 50130-4:2011 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN 50130-4:2011/A1:2014 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: PAL,SECAM,DVB,Satellite |
소재지 |
| CISPR 32:2015/AMD1:2019 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: PAL,SECAM,DVB,Satellite |
소재지 |
| EN 55032:2015 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: PAL,SECAM,DVB,Satellite |
소재지 |
| EN 55032:2015/A11:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: PAL,SECAM,DVB,Satellite |
소재지 |
| EN 55032:2015/A1:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: PAL,SECAM,DVB,Satellite |
소재지 |
| AS/NZS CISPR 32:2015 AMD1:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: PAL,SECAM,DVB,Satellite |
소재지 |
| EN 55035:2017 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN 55035:2017/A11:2020 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| CISPR 35:2016 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| ETSI EN 301 489-1 V2.2.3 (2019-11) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility (Exception) vehicular equipment and above 16 A equipment |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| ETSI EN 301 489-3 V2.3.2 (2023-01) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonised Standard for ElectroMagnetic Compatibility (Exception) vehicular equipment and above 16 A equipment |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| ETSI EN 301 489-17 V3.3.1 (2024-09) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband and Wideband Data Transmission Systems; Harmonised Standard for ElectroMagnetic Compatibility (Exception) vehicular equipment and above 16 A equipment |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN IEC 61326-2-2:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN IEC 61000-6-1:2019 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100% |
소재지 |
| EN IEC 61326-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| CISPR 11:2024 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN 55011:2016 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN 55011:2016/A1:2017 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN 55011:2016/A2:2021 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN IEC 55011:2025 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| IEC 61000-3-3:2013+AMD1:2017+AMD2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
Voltage: max. 440 V Current: max. 16 A RA = 0,24 Ω; jXA = 0,15 Ω at 50 Hz RN = 0,16 Ω; jXN = 0,10 Ω at 50 Hz |
소재지 |
| EN 61000-3-3:2013 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
Voltage: max. 440 V Current: max. 16 A RA = 0,24 Ω; jXA = 0,15 Ω at 50 Hz RN = 0,16 Ω; jXN = 0,10 Ω at 50 Hz |
소재지 |
| EN 61000-3-3:2013/A1:2019 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
Voltage: max. 440 V Current: max. 16 A RA = 0,24 Ω; jXA = 0,15 Ω at 50 Hz RN = 0,16 Ω; jXN = 0,10 Ω at 50 Hz |
소재지 |
| EN 61000-3-3:2013/A2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
Voltage: max. 440 V Current: max. 16 A RA = 0,24 Ω; jXA = 0,15 Ω at 50 Hz RN = 0,16 Ω; jXN = 0,10 Ω at 50 Hz |
소재지 |
| EN 61000-3-3:2013/A2:2021/AC:2022-01 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
Voltage: max. 440 V Current: max. 16 A RA = 0,24 Ω; jXA = 0,15 Ω at 50 Hz RN = 0,16 Ω; jXN = 0,10 Ω at 50 Hz |
소재지 |
| IEC 61000-3-2:2018+AMD1:2020+AMD2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
Voltage: max. 440 V Current: max. 16 A Harmonics: 40 degree |
소재지 |
| EN 61000-3-2:2014 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
Voltage: max. 440 V Current: max. 16 A Harmonics: 40 degree |
소재지 |
| EN IEC 61000-3-2:2019 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
Voltage: max. 440 V Current: max. 16 A Harmonics: 40 degree |
소재지 |
| EN IEC 61000-3-2:2019/A1:2021 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
Voltage: max. 440 V Current: max. 16 A Harmonics: 40 degree |
소재지 |
| EN IEC 61000-3-2:2019/A2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
Voltage: max. 440 V Current: max. 16 A Harmonics: 40 degree |
소재지 |
| IEC 61000-6-4:2018 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN IEC 61000-6-4:2019 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| IEC 61000-6-3:2020 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN IEC 61000-6-3:2021 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| IEC 61000-6-2:2016 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100% |
소재지 |
| EN IEC 61000-6-2:2019 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100% |
소재지 |
| IEC 61000-6-1:2016 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100% |
소재지 |
| EN 55013:2013+A1:2016 |
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: NTSC, ATSC, PAL, SECAM, DVB, Satellite |
소재지 |
| IEC 61326-2-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| EN IEC 61326-2-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| IEC 61326-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| IEC 60945:2002/COR1:2008 |
Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results |
Test Frequency: 9 kHz ~ 2 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max.100 % |
소재지 |
| EN 60945:2002 |
Maritime navigation and radio communication equipment and systems - General requirements - Methods of testing and required test results |
Test Frequency: 9 kHz ~ 2 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max.100 % |
소재지 |
| CISPR 14-2:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN 55014-2:1997 |
Electromagnetic compatibility - Requirements for household appliances , electric tools and similar apparatus - Part 2: Immunity - Product family standard |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN 55014-2:1997/A1:2001 |
Electromagnetic compatibility - Requirements for household appliances , electric tools and similar apparatus - Part 2: Immunity - Product family standard |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN 55014-2:1997/A2:2008 |
Electromagnetic compatibility - Requirements for household appliances , electric tools and similar apparatus - Part 2: Immunity - Product family standard |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN 55014-2:1997/AC:1997 |
Electromagnetic compatibility - Requirements for household appliances , electric tools and similar apparatus - Part 2: Immunity - Product family standard |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN 55014-2:2015 |
Electromagnetic compatibility - Requirements for household appliances , electric tools and similar apparatus - Part 2: Immunity - Product family standard |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN IEC 55014-2:2021 |
Electromagnetic compatibility - Requirements for household appliances , electric tools and similar apparatus - Part 2: Immunity - Product family standard |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| AS/NZS CISPR 14.1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| CISPR 14-1:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN 55014-1:2017 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN 55014-1:2017/A11:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN IEC 55014-1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| AS/NZS CISPR 13:2012/AMD1:2015 |
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: NTSC, ATSC, PAL, SECAM, DVB, Satellite |
소재지 |
| CISPR 13:2009+AMD1:2015 CSV |
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement |
Test Frequency:150 kHz ~ 18 GHz Voltage: max. 440 V Current:max. 16 A Signal system:NTSC, ATSC, PAL, SECAM, DVB, Satellite |
소재지 |
| IEC 61326-2-2:2020 |
Electrical equipment for measurement, control and laboratory use – EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| CISPR 15:2018 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN IEC 55015:2019 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| EN IEC 55015:2019/A11:2020 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
Test Frequency: 9 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A |
소재지 |
| IEC 61547:2020 |
Equipment for general lighting purposes – EMC immunity requirements |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN 61547:2009 |
Equipment for general lighting purposes - EMC immunity requirements |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| EN IEC 61547:2023 |
Equipment for general lighting purposes - EMC immunity requirements |
Test Frequency: 150 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max. 100 % |
소재지 |
| QCVN 18:2022/BTTTT |
National technical regulation on Electromagnetic compatibility for Radio Communications Equipment |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Magnetic intensity: max. 30 A/m Voltage dip&Interruption: max.100 % |
소재지 |
| QCVN 118:2018/BTTTT |
National technical regulation on Electromagnetic compatibility of multimedia equipment - Emission requirements |
Test Frequency: 150 kHz ~ 18 GHz Voltage: max. 440 V Current: max. 16 A Signal system: PAL,SECAM,DVB,Satellite |
소재지 |
IACS UR E 10 Test Specification for Type Approval:2024 |
Type testing condition for equipment covered by E10.1 3. External power supply failure 4. Power supply variations a) electric 13. Electrostatic discharge 14. Electromagnetic field 15. Conducted low frequency 16. Conducted radio frequency 17. Electrical Fast Transients/Burst 18. Surge 19. Radiated emission 20. Conducted emission |
Test Frequency: 9 kHz ~ 6 GHz Voltage: max. 440 V Current: max. 16 A ESD: max. 10 kV RS: max. 10 V/m CS: max. 10 V Burst: max. 4 kV Surge: max. 4 kV Voltage dip&Interruption: max.100 % |
소재지 |
| FCC 47 CFR Part 15, Subpart B |
Unintentional Radiators |
CE : 9 kHz ~ 30 MHz, RE : 9 kHz ~ 40 GHz |
소재지 |
| FCC 47 CFR Part 18 |
Industrial, Scientific, and Medical Equipment (ISM Equipment) |
CE : 9 kHz ~ 30 MHz, RE : 9 kHz ~ 40 GHz |
소재지 |
| ▶ 산업용 전기기기 |
| KS C IEC 60204-1:2016 |
기계류의 안전성 - 기계의 전기장비 - 제1부: 일반 요구사항 (시험 가능 범위) 18.2.2 시험1- 보호 접지 회로의 연속성 검증 18.3 절연 저항 시험 18.4 전압 시험 18.5 잔류 전압 보호 |
보호 접지 회로의 연속성: (0.2 ~ 25) A 절연 저항: DC 500 V,(1 ~ 199.9) MΩ 전압 시험: AC (1 ~ 5) kV 잔류 전압 보호: Max. 120 V |
소재지 |
| IEC 60204-1:2016 |
Safety of machinery - Electricalequipment of machines - Part 1:General requirements(Test items) 18.2.2 Test1-Verification of the continuity of the protective bonding circuit 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit:(0.2 ~ 25) A Insulation resistance:DC 500 V, (1 ~ 199.9) MΩ Voltage test: AC (1 ~ 5) kV, Residual voltage:Max.120 V |
소재지 |
| IEC 60204-1:2016/AMD1:2021 |
Safety of machinery - Electricalequipment of machines - Part 1:General requirements(Test items) 18.2.2 Test1-Verification of the continuity of the protective bonding circuit 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Continuity of the protective bonding circuit:(0.2 ~ 25) A Insulation resistance:DC 500 V, (1 ~ 199.9) MΩ Voltage test: AC (1 ~ 5) kV, Residual voltage:Max.120 V |
소재지 |