| ▶ 가정용 전기기기 |
| IEC 62368-1:2018 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.4.12 Insulating liquid 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.5.3.4 Transformer using fully insulated winding wire (FIW) Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex X Alternative measurement method for spatial distance measurement of insulation in circuits connected to AC mains (300 V RMS) (Trace Index Test/Mandrel Test in accordance with KS C IEC 60112) Annex Y.2 Resistance to UV radiation Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance (Test) Annex Y.5 Protection from moisture Annex Y.5.3 Water spray test Annex Y.5.5 Protection from excessive dust |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
EN IEC 62368- 1:2020+A11:2020 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements
[Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.4.12 Insulating liquid 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.5.3.4 Transformer using fully insulated winding wire (FIW) Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex X Alternative measurement method for spatial distance measurement of insulation in circuits connected to AC mains (300 V RMS) (Trace Index Test/Mandrel Test in accordance with KS C IEC 60112) Annex Y.2 Resistance to UV radiation Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance (Test) Annex Y.5 Protection from moisture Annex Y.5.3 Water spray test Annex Y.5.5 Protection from excessive dust |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| KC 62368-1:2025-10-27 |
전기용품안전기준: 오디오/비디오 및 정보통신기술기기, 제1부: 안전 요구 사항 [제외항목] 5.4.1.5.3 열 사이클링 시험절차 5.4.1.10.2 연화온도(Vicat) 시험 5.4.3.3 재질 그룹 및 비교 트래킹 지수(CTI) 5.4.4.6.5 맨드릴(Mandrel) 시험 5.4.7 반도체 부품(소자)와 접합(부)에 대한 시험 5.4.12 절연유 5.5.2 캐패시터 및 RC 장치(부속서 G.11 시험) 5.6.4.1 과전류 보호장치와 회로의 시험(부속서 R) 7.3 오존 노출 8.5.5 고압 램프 8.8 핸드(손잡이) 강도 8.12 텔레스코핑 또는 로드 안테나(부속서 T.11) 10 방사(선) 부속서 B.2.5 3상 전압 시스템 부속서 C 자외선(UV radiation) 부속서 G.1 스위치(시험) 부속서 G.2 릴레이(시험) 부속서 G.3 보호 수단장치(시험) 부속서 G.5.1 권선 부품에 전선 절연 부속서 G.5.3.4 FIW(완전 절연 권선)을 사용한 변압기(시험) 부속서 G.6 전선 절연(시험) 부속서 G.7 KS C IEC 60227에 따른 시험 부속서 G.8 배리스터(시험) 부속서 G.9 집적회로(IC) 전류 제한기(시험) 부속서 G.10 저항 부속서 G.11 캐패시터 및 RC 장치(시험) 부속서 G.12 광 커플러(옵터 커플러)(시험) 부속서 G.13.6 코팅 인쇄기판 시험 부속서 G.14 부품 단자 위 코팅 부속서 G.15 가압 액체로 채워진 부품 부속서 H 전화벨(링) 신호에 대한 기준 부속서 J 중간 절연 없이 사용하기 위한 절연 권선 전선(시험) 부속서 K 안전 인터락(시험) 부속서 M.7 납축전지 및 니켈-카드뮴 배터리의 폭발 위험 부속서 M.8 수성 전해액 배터리의 외부 스파크 원으로부터 내부 점화에 대한 보호 부속서 R 제한 단락 회로 시험 부속서 U CRTs의 기계적 강도 및 내파 영향에 대한 보호 부속서 X 420 V 피크(300 V RMS)를 초과하지 않는 AC 주전원에 연결된 회로에서 절연의 공간거리 측정을 위한 대체 방안(KS C IEC 60112에 따른 트래킹 지수 시험/맨드릴(Mandrel) 시험) 부속서 Y.2 자외선에 대한 내성(시험) 부속서 Y.3 부식에 대한 내성(시험) 부속서 Y.3.3 수포화 이산화황 (시험) 부속서 Y.4.3 인장 강도 및 연신율 시험 부속서 Y.4.4 압축 시험 부속서 Y.4.5 내유성(시험) 부속서 Y.5 습기로부터의 보호 부속서 Y.5.3 물 분무 시험 부속서 Y.5.5 과도한 먼지로부터의 보호 |
전원전압: Max. 300 V 온도: Max. 200 °C 내전압: Max. 10 kV 접촉전류: Max. 10 mA |
소재지 |
| QCVN 132:2022/BTTTT |
National technical regulation on electrical safety requirements for telecommunication and information terminal equipment [Exception] 2.2.4.1.5.3 Thermal cycling test procedure 2.2.4.1.10.2 Vicat test 2.2.4.3.3 Material group and CTI 2.2.4.4.6.5 Mandrel test 2.2.4.7 Tests for semiconductor components and for cemented joints 2.2.4.12 Insulating liquid 2.2.5.2 Capacitors and RC units 2.2.6.4.1 Determination of the overcurrent protective device and circuit (Annex P) Annex A.2.5 Three-phase voltage systems Annex D.1 Switches (Test) Annex D.2 Relays (Test) Annex D.3 Protective devices (Test) Annex D.5.1 Wire insulation in wound components Annex D.5.3.4 Transformer using fully insulated winding wire (FIW) Annex D.6 Wire insulation (Test) Annex D.7 Test according to IEC 60227 Annex D.8 Varistors (Test) Annex D.9 Integrated circuit (IC) current limiters (Test) Annex D.10 Test for resistor serving as safeguard Test sequence Annex D.11 Capacitors and RC units (Test) Annex D.12 Optocouplers (Test) Annex D.13.6 Tests on coated printed boards Annex D.14 Coatings on component terminals Annex D.15 Pressurized liquid filled components Annex E Criteria for telephone ringing signals Annex H Insulated winding wires for use without interleaved insulation (Test) Annex I Safety interlocks (Test) Annex K Disconnect devices (Three-phase equipment Test) Annex P Limited short-circuit test Annex S Alternative measurement method for spatial distance measurement of insulation in circuits connected to AC mains (300 V RMS) (Trace Index Test/Mandrel Test in accordance with KS C IEC 60112) |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| UL 62368-1, Ed.3, Rev. October 22, 2021 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.4.12 Insulating liquid 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.5.3.4 Transformer using fully insulated winding wire (FIW) Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex X Alternative measurement method for spatial distance measurement of insulation in circuits connected to AC mains (300 V RMS) (Trace Index Test/Mandrel Test in accordance with KS C IEC 60112) Annex Y.2 Resistance to UV radiation Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance (Test) Annex Y.5 Protection from moisture Annex Y.5.3 Water spray test Annex Y.5.5 Protection from excessive dust |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| CSA C22.2 NO. 62368-1:19, Rev. October 22, 2021 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.4.12 Insulating liquid 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.5.3.4 Transformer using fully insulated winding wire (FIW) Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex X Alternative measurement method for spatial distance measurement of insulation in circuits connected to AC mains (300 V RMS) (Trace Index Test/Mandrel Test in accordance with KS C IEC 60112) Annex Y.2 Resistance to UV radiation Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance (Test) Annex Y.5 Protection from moisture Annex Y.5.3 Water spray test Annex Y.5.5 Protection from excessive dust |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| KS C IEC 62368-1:2018 |
한국산업표준: 오디오/비디오 및 정보통신기술기기, 제1부: 안전 요구 사항 [제외항목] 5.4.1.5.3 열 사이클링 시험절차 5.4.1.10.2 연화온도(Vicat) 시험 5.4.3.3 재질 그룹 및 비교 트래킹 지수(CTI) 5.4.4.6.5 맨드릴(Mandrel) 시험 5.4.7 반도체 부품(소자)와 접합(부)에 대한 시험 5.4.12 절연유 5.5.2 캐패시터 및 RC 장치(부속서 G.11 시험) 5.6.4.1 과전류 보호장치와 회로의 시험(부속서 R) 7.3 오존 노출 8.5.5 고압 램프 8.8 핸드(손잡이) 강도 8.12 텔레스코핑 또는 로드 안테나(Annex T.11) 10 방사(선) 부속서 B.2.5 3상 전압 시스템 부속서 C 자외선(UV radiation) 부속서 G.1 스위치(시험) 부속서 G.2 릴레이(시험) 부속서 G.3 보호수단 장치(시험) 부속서 G.5.1 권선 부품에 전선 절연 부속서 G.5.3.4 FIW(완전 절연 권선)을 사용한 변압기(시험) 부속서 G.6 전선 절연(시험) 부속서 G.7 KS C IEC 60227에 따른 시험 부속서 G.8 배리스터(시험) 부속서 G.9 집적회로(IC) 전류 제한기(시험) 부속서 G.10 저항 부속서 G.11 캐패시터 및 RC 장치(시험) 부속서 G.12 광 커플러(옵터 커플러)(시험) 부속서 G.13.6 코팅 인쇄기판 시험 부속서 G.14 부품 단자 위 코팅 부속서 G.15 가압 액체로 채워진 부품 부속서 H 전화벨(링) 신호에 대한 기준 부속서 J 중간절연 없이 사용하기 위한 절연권선 전선(시험) 부속서 K 안전 인터락(시험) 부속서 M.7 납축전지 및 니켈-카드뮴 배터리의 폭발 위험 부속서 M.8 수성 전해액 배터리의 외부 스파크 원으로부터 내부 점화에 대한 보호 부속서 R 제한 단락 회로 시험 부속서 U CRTs의 기계적 강도 및 내파 영향에 대한 보호 부속서 X 420 V 피크(300 V RMS)를 초과하지 않는 AC 주전원에 연결된 회로에서 절연의 공간거리 측정을 위한 대체 방안(KS C IEC 60112에 따른 트래킹 지수 시험/맨드릴(Mandrel) 시험) 부속서 Y.2 자외선에 대한 내성(시험) 부속서 Y.3 부식에 대한 내성(시험) 부속서 Y.3.3 수포화 이산화황(시험) 부속서 Y.4.3 인장 강도 및 연신율 시험 부속서 Y.4.4 압축 시험 부속서 Y.4.5 내유성(시험) 부속서 Y.5 습기로부터의 보호 부속서 Y.5.3 물 분무 시험 부속서 Y.5.5 과도한 먼지로부터의 보호 |
전원전압: Max. 300 V 온도: Max. 200 °C 내전압: Max. 10 kV 접촉전류: Max. 10 mA |
소재지 |
| IEC 62368-1:2014 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| UL 62368-1, Ed.2, Rev. December 01, 2014 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| CSA C22.2 NO. 62368-1:14 (R2019), Rev, February, 2014 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| IEC 62368-1:2023 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.4.12 Insulating liquid 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.5.3.4 Transformer using fully insulated winding wire (FIW) Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex X Alternative measurement method for spatial distance measurement of insulation in circuits connected to AC mains (300 V RMS) (Trace Index Test/Mandrel Test in accordance with KS C IEC 60112) Annex Y.2 Resistance to UV radiation Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance (Test) Annex Y.5 Protection from moisture Annex Y.5.3 Water spray test Annex Y.5.5 Protection from excessive dust |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
EN IEC 62368- 1:2024+A11:2024 |
Audio/video, information and communication technology equipment – Part 1: Safety requirements [Exception] 5.4.1.5.3 Thermal cycling test procedure 5.4.1.10.2 Vicat test 5.4.3.3 Material group and CTI 5.4.4.6.5 Mandrel test 5.4.7 Tests for semiconductor components and for cemented joints 5.4.12 Insulating liquid 5.5.2 Capacitors and RC units 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 7.3 Ozone exposure 8.5.5 High pressure lamps 8.8 Handle strength test method 8.12 Telescoping or rod antennas (Annex T.11) 10 Radiation (Test) Annex B.2.5 Three-phase voltage systems Annex C UV radiation Annex G.1 Switches (Test) Annex G.2 Relays (Test) Annex G.3 Protective devices (Test) Annex G.5.1 Wire insulation in wound components Annex G.5.3.4 Transformer using fully insulated winding wire (FIW) Annex G.6 Wire insulation (Test) Annex G.7 Test according to IEC 60227 Annex G.8 Varistors (Test) Annex G.9 Integrated circuit (IC) current limiters (Test) Annex G.10 Test for resistor serving as safeguard Test sequence Annex G.11 Capacitors and RC units (Test) Annex G.12 Optocouplers (Test) Annex G.13.6 Tests on coated printed boards Annex G.14 Coatings on component terminals Annex G.15 Pressurized liquid filled components Annex H Criteria for telephone ringing signals Annex J Insulated winding wires for use without interleaved insulation (Test) Annex K Safety interlocks (Test) Annex L Disconnect devices (Three-phase equipment Test) Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte Annex R Limited short-circuit test Annex S Tests for resistance to heat and fire Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex X Alternative measurement method for spatial distance measurement of insulation in circuits connected to AC mains (300 V RMS) (Trace Index Test/Mandrel Test in accordance with KS C IEC 60112) Annex Y.2 Resistance to UV radiation Annex Y.3 Resistance to corrosion Annex Y.3.3 Water-saturated sulphur dioxide atmosphere Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression tests Annex Y.4.5 Oil resistance (Test) Annex Y.5 Protection from moisture Annex Y.5.3 Water spray test Annex Y.5.5 Protection from excessive dust |
Input Voltage: Max. 300 V Heating: Max. 200 °C Withstanding voltage: Max. 10 kV Touch current: Max. 10 mA |
소재지 |
| UL 62368-1, Edition 4 (July 31, 2025), |
Audio/video, information and communication technology equipment - Part 1: Safety requirements |
Input Voltage: Max. 300 V Heating : Max. 200 °C Withstanding voltage: Max. 10 kV |
소재지 |
| CSA C22.2 NO. 62368-1:25, Edition 4 (July, 2025) |
Audio/video, information and communication technology equipment - Part 1: Safety requirements |
Input Voltage: Max. 300 V Heating : Max. 200 °C Withstanding voltage: Max. 10 kV |
소재지 |
| ▶ 유/무선 통신기기 |
ETSI EN 302 291-1 V1.1.1:2005 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Close Range Inductive Data Communication equipment operating at 13,56 MHz; Part 1: Technical characteristics and test methods |
9 kHz to 1 GHz |
소재지 |
AS/NZS 4268:2017 |
Radio equipment and systems - short range devices - Limits and methods of measurement |
9 kHz ~ 26.5 GHz |
소재지 |
| EN 50663:2017 |
Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz) |
10 MHz ~ 40 GHz |
소재지 |
| IEC/IEEE 62209-1528:2020 |
Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-worn wireless communication devices - Human models, instrumentation and procedures (Frequency range of 4 MHz to 10 GHz) |
4 MHz to 10 GHz |
소재지 |
| EN IEC/IEEE 62209-1528:2021 |
Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-worn wireless communication devices - Human models, instrumentation and procedures (Frequency range of 4 MHz to 10 GHz) |
4 MHz to 10 GHz |
소재지 |
| EN 50566:2018 |
Product standard to demonstrate the compliance of wireless communication devices with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 30 MHz to 6 GHz : hand-held and body mounted devices in close proximity to the human body |
30 MHz ~ 6 GHz |
소재지 |
| EN 50360:2017 |
Product standard to demonstrate the compliance of wireless communication devices, with the basic restrictions and exposure limit values related to human exposure to electromagnetic fields in the frequency range from 300 MHz to 6 GHz: devices used next to the ear |
300 MHz ~ 6 GHz |
소재지 |
| EN 62479:2010 |
Assessment of the compliance of lowpower electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
10 MHz ~ 40 GHz |
소재지 |
| EN 62311:2020 |
Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz) |
9 kHz ~ 40 GHz |
소재지 |
ETSI EN 303 417 V1.1.1:2017 |
Wireless power transmission systems, using technologies other than radio frequency beam in the 19 - 21 kHz, 59 - 61 kHz, 79 - 90 kHz, 100 - 300 kHz, 6 765 - 6 795 kHz ranges; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
9 kHz to 1 GHz |
소재지 |
| ETSI EN 302 291-2V1.1.1:2005 |
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Close Range Inductive Data Communication equipment operating at 13,56 MHz; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive |
9 kHz to 1 GHz |
소재지 |
ETSI EN 303 413 V1.2.1:2021 |
Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum |
30 MHz to 8.3 GHz |
소재지 |
ETSI EN 300 440 V2.2.1:2018 |
Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Harmonised Standard for access to radio spectrum |
25 MHz to 40 GHz |
소재지 |
ETSI EN 300 330 V2.1.1:2017 |
Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
9 kHz to 1 GHz |
소재지 |
ETSI EN 300 220-2 V3.3.1:2025 |
Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 2: Harmonised Standard for access to radio spectrum for non specific radio equipment |
25 MHz to 6 GHz |
소재지 |
ETSI EN 300 220-1 V3.1.1:2017 |
Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 1: Technical characteristics and methods of measurement |
25 MHz to 6 GHz |
소재지 |
ETSI EN 301 893 V2.2.1:2024 |
5 GHz WAS/RLAN; Harmonised Standard for access to radio spectrum |
30 MHz to 26 GHz |
소재지 |
ETSI EN 300 328 V2.2.2:2019 |
Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum |
30 MHz to 12.75 GHz |
소재지 |
ETSI EN 303 687 V1.1.1(2023.06) |
6 GHz WAS/RLAN; Harmonised Standard for access to radio spectrum |
30 MHz to 26 GHz |
소재지 |
| QCVN 54:2020/BTTTT |
National technical regulation on wideband data transmission equipment operating in the 2,4 GHz band |
30 MHz to 12.75 GHz |
소재지 |
| QCVN 55:2023/BTTTT |
NATIONAL TECHNICAL REGULATION ON SHORT RANGE DEVICE (SRD) - RADIO EQUIPMENT TO BE USED IN THE 9 kHz TO 25 MHz FREQUENCY RANGE AND INDUCTIVE LOOP SYSTEMS IN THE FREQUENCY RANGE 9 kHz TO 30 MHz |
9 kHz to 1 GHz |
소재지 |
| QCVN 65:2021/BTTTT |
NATIONAL TECHNICAL REGULATION ON RADIO ACCESS EQUIPMENT OPERATING IN THE 5 GHZ BAND |
30 MHz to 26 GHz |
소재지 |
| QCVN 117:2023/BTTTT |
National technical regulation on GSM, W-CDMA, E-UTRA Land Mobile User Equipment - Radio Access |
GSM, W-CDMA, E-UTRA |
소재지 |
| QCVN 127:2021/BTTTT |
National technical regulation on Standalone 5G User Equipment - Radio Access |
SA 5G |
소재지 |
| QCVN 129:2021/BTTTT |
National technical regulation on Non Standalone 5G User Equipment - Radio Access |
NSA 5G |
소재지 |
| ▶ 전자기적합성 |
| ANSI C63.4-2014 |
American National Standard for Methods of Measurement of Radio- Noise Emissions from Low-Voltage Electrical and Electronic Equipment in Range of 9 ㎑ ∼ 40 ㎓ |
RE : 9kHz - 40 GHz CE : 9kHz - 30 MHz |
소재지 |
| AS/NZS CISPR 11:2024 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement [Exception] Radiation disturbance test of 30 m measuring distance of Group 2 Class A equipment |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 18 GHz CE : 9 kHz ∼ 30 MHz |
소재지 |
| AS/NZS CISPR 14.1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus, Part 1: Emission |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 1 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
| AS/NZS CISPR 15:2025 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment [Exception] 4.5.2 3m, 4m loop antenna radiation |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 300 MHz CE : 9 kHz ∼ 30 MHz |
소재지 |
| AS IEC 61000.4.5:2017 |
Electromagnetic compatibility (EMC) - Part 4.5:Testing and measurement techniques - Surge immunity test |
1 phase equipment, ≤ 16 A Surge : Max. ±4 kV |
소재지 |
| AS/NZS IEC 61000.4.6:2024 |
Electromagnetic compatibility (EMC) - Part 4.6:Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
1 phase equipment, ≤ 16 A CS : 150 kHz ~ 230 MHz, 10 V |
소재지 |
| AS 61000.6.4:2020 |
Electromagnetic compatibility (EMC), Part 6.4:Generic standards - Emission standard for industrial environments |
RE : 30 MHz ~ 6 GHz CE : 0.15 MHz ~ 30 MHz |
소재지 |
| AS/NZS CISPR 14.2:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
1 phase equipment, ≤ 16 A ESD : Air ±30 kV Contact ±25 kV RS : 80 MHz ~ 1 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ~ 230 MHz, 3 V M/F : 10 A/m V-DIP : 0 ~ 100 % |
소재지 |
| AS/NZS CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
1 phase equipment, ≤ 16 A RE : 30 MHz ~ 6 GHz CE : 0.15 MHz ~ 30 MHz |
소재지 |
AS/NZS CISPR 32:2015 AMD 1:2020 |
Electromagnetic compatibility of multimedia equipment - Emission requirements |
1 phase equipment, ≤ 16 A RE : 30 MHz ~ 6 GHz CE : 0.15 MHz ~ 30 MHz |
소재지 |
| AS/NZS IEC 61000.4.2:2013 |
Electromagnetic compatibility (EMC) Part 4.2:Testing and measurement techniques - Electrostatic discharge immunity test |
1 phase equipment, ≤ 16 A ESD : Max. ±30 kV |
소재지 |
| AS/NZS IEC 61000.4.3:2021 |
Electromagnetic compatibility (EMC) Part 4.3:Testing and measurement techniques - Radiated, radio - Frequency, electromagnetic field immunity test |
1 phase equipment, ≤ 16 A RS : 80 MHz ∼ 6 GHz, 10 V/m |
소재지 |
| AS/NZS IEC 61000.4.4:2013 |
Electromagnetic compatibility (EMC) Part 4.4:Testing and measurement techniques - Electrical fast transient/burst immunity test |
1 phase equipment, ≤ 16 A EFT : Max. ±4 kV |
소재지 |
| AS/NZS IEC 61000.3.2:2023 |
Electromagnetic compatibility (EMC) Part 3.2:Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
1 phase equipment, ≤ 16 A |
소재지 |
| AS/NZS IEC 61000.3.3:2023 |
Electromagnetic compatibility (EMC) Part 3.3:Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection |
1 phase equipment, ≤ 16 A |
소재지 |
| AS/NZS 61000.4.11:2005 |
Electromagnetic compatibility (EMC) Part 4.11:Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
1 phase equipment, ≤ 16 A V-DIP: Max. 100 % |
소재지 |
| AS/NZS 61000.4.8:2012 |
Electromagnetic compatibility (EMC) Part 4.8:Testing and measurement techniques - Power frequency magnetic field immunity test |
1 phase equipment, ≤ 16 A M/F : Max. 30 A/m |
소재지 |
| AS/NZS 61000.6.1:2025 |
Electromagnetic compatibility (EMC) Part 6.1:Generic standards - Immunity for residential, commercial and light-industrial environments |
1 phase equipment, ≤ 16 A ESD : AIR ±8 kV CONTACT ±4 kV RS : 80 MHz ~ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ~ 80 MHz, 3 V M/F : 3 A/m V-DIP : 0 ~ 100 % |
소재지 |
| AS/NZS 61000.6.2:2022 |
Electromagnetic compatibility (EMC) Part 6.2:General standards - Immunity for industrial environments |
1 phase equipment, ≤ 16 A ESD : AIR ±8 kV CONTACT ±4 kV RS : 80 MHz ~ 6 GHz,10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ~ 80 MHz, 10 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
| AS/NZS 61000.6.3:2021 |
Electromagnetic compatibility (EMC) Part 6.3:Generic standards - Emission standard for equipment in residential environments |
1 phase equipment, ≤ 16 A RE : 30 MHz ~ 6 GHz CE : 0.15 MHz ~ 30 MHz |
소재지 |
| CISPR 11:2024 |
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement [Exception] 8 Special provisions for test site measurements |
RE : 9 kHz ∼ 18 GHz CE : 9 kHz ∼ 30 MHz |
소재지 |
| CISPR 14-1:2020 |
Electromagnetic compatibility – Requirements for household appliances, electric tools and similar apparatus – Part 1:Emission |
RE : 9 kHz ∼ 1 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
| CISPR 14-2:2020 |
Electromagnetic compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 2:Immunity Product family standard |
ESD : ±8 kV RS : 80 MHz ∼ 1 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 230 MHz, 3 V V-DIP : 0 ∼ 100 % |
소재지 |
| CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz DV : 30 MHz ∼ 2.15 GHz |
소재지 |
| CISPR 32:2015+A1:2019 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz DV : 30 MHz ∼ 2.15 GHz |
소재지 |
| CISPR 35:2016 |
Electromagnetic compatibility of multimedia equipment- Immunity requirements Table 2 - Immunity requirements [Exception] analogue/digital data ports: 2.2 Broadband impulse noise disturbances repetitive 2.3 Broadband impulse noise disturbances, isolated |
ESD : ±8 kV RS : 80 MHz ∼ 6 GHz EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz M/F : 1 A/m V-DIP : 0 ∼ 100 % |
소재지 |
| CISPR 15:2018+A1:2024 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
RE : 9 kHz ~ 1 GHz CE : 9 kHz ~ 30 MHz |
소재지 |
| EN 50130-4:2011/A1:2014 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder,hold up, CCTV, access control and social alarm systems |
ESD : ±8 kV RS : 80 MHz ∼ 2 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 100 MHz, 10 V V-DIP : 0 ∼ 100 % |
소재지 |
| EN 55032:2015 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz DV : 30 MHz ∼ 2.15 GHz |
소재지 |
| EN 60945:2002 |
Maritime navigation and radio communication equipment and systems — General requirements — Methods of testing and required test results |
RE : 150 kHz ~ 2 GHz CE : 10 kHz ~ 30 MHz ESD : ±8 kV RS : 80 MHz ~ 2 GHz, 10 V/m EFT : ±2.0 kV Surge : ±1.0 kV CS : 150 kHz ~ 80 MHz, 10 V V-DIP : 0 ~ 100 % |
소재지 |
| EN 61000-3-3:2013/A2:2021/AC:2022-01 |
Electromagnetic compatibility (EMC) - Part 3-3:Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection |
1 phase equipment, ≤ 16 A |
소재지 |
| EN 61000-4-2:2009 |
Electromagnetic compatibility (EMC) — Part 4-2:Testing and measurement techniques - Electrostatic discharge immunity test |
ESD : ±30 kV |
소재지 |
| EN 61000-4-4:2012 |
Electromagnetic compatibility(EMC) — Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EFT : ±4 ㎸ |
소재지 |
| EN 61000-4-5:2014/A1:2017 |
Electromagnetic compatibility (EMC) - Part 4-5:Testing and measurement techniques - Surge immunity test |
1 phase equipment, ≤ 16 A Surge : ±6 kV |
소재지 |
| EN IEC 61000-4-6:2023 |
Electromagnetic compatibility (EMC) — Part 4-6:Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CS : 150 kHz ∼ 230 MHz |
소재지 |
| EN 61000-4-8:2010 |
Electromagnetic compatibility (EMC) Part 4-8:Testing and measurement techniques - Power frequency magnetic field immunity test |
M/F : 30 A/m |
소재지 |
| EN IEC 61204-3:2018 |
Low voltage power supplies, d.c. output - Part 3:Electromagnetic compatibility (EMC) |
RE : 30 MHz ∼ 1 GHz CE : 150 kHz ∼ 30 MHz ESD : ±8 kV RS : 80 MHz ∼ 1 GHz, 3 V/m EFT : ±1 kV SURGE : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ∼ 100 % |
소재지 |
| EN IEC 61326-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements Part1:General requirements |
ESD : ±8 kV, RS : 80 MHz ∼ 2.7 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
| EN IEC 61547:2023 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD : ±8 kV RS : 80 MHz ∼ 1 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 1 A/m, V-DIP : 0 ∼ 100 % |
소재지 |
EN IEC 55014- 1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
EN IEC 55014- 2:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 230 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61000-3- 2:2019/A1:2021 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
1 phase equipment, ≤ 16 A |
소재지 |
EN IEC 61000-4- 11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
1 phase equipment, ≤ 16 A V-DIP : 0 ∼ 100 % |
소재지 |
EN IEC 61000-4- 3:2020 |
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
RS : 80 MHz ∼ 6 GHz |
소재지 |
EN IEC 61000-6- 1:2019 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and lightindustrial environments |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 3 A/m V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61000-6- 2:2019 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV SURGE : ±2 kV CS : 150 kHz ∼ 80 MHz, 10 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61000-6- 3:2021 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
EN IEC 61000-6- 4:2019 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
EN IEC 61326- 1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1:General requirements |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 ㎑ ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61326-2- 1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1:Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61326-2- 2:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2:Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61326-2- 3:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3:Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61326-2- 4:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4:Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557- 8 and for equipment for insulation fault location according to IEC 61557- 9 |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
EN IEC 61326-2- 5:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5:Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784- 1 |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
| EN IEC 55015:2019/A11:2020 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 1 GHz CE : 9 kHz ∼ 30 MHz |
소재지 |
| EN IEC 55011:2025 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 18 GHz CE : 9 kHz ∼ 30 MHz |
소재지 |
| EN 55032:2015/A1:2020 |
Electromagnetic compatibility of multimedia equipment- Emission Requirements |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz DV : 30 MHz ∼ 2.15 GHz |
소재지 |
| EN 55032:2015/A11:2020 |
Electromagnetic compatibility of multimedia equipment - Emission Requirements |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz DV : 30 MHz ∼ 2.15 GHz |
소재지 |
| EN 55035:2017/A11:2020 |
Electromagnetic compatibility of multimedia equipment- Immunity Requirements Table 2 Immunity requirements for analogue/digital data ports:2.2 Broadband impulse noise disturbances repetitive 2.3 Broadband impulse noise disturbances, isolated |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±4 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 1 A/m V-DIP : 0 ∼ 100 % |
소재지 |
ETSI EN 301 489- 15 V2.2.1:2019 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 15:Specific conditions for commercially available amateur radio equipment; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| ETSI EN 301 489-17 V3.3.1:2024 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17:Specific conditions for Broadband and Wideband Data Transmission Systems; Harmonised Standard for ElectroMagnetic Compatibility |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| ETSI EN 301 489-19 V2.2.1:2022 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19:Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band providing positioning, navigation, and timing data; Harmonised Standard for ElectroMagnetic Compatibility |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| ETSI EN 301 489-50 V2.4.1:2025 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 50:Specific conditions for Cellular Communication Base Station (BS), repeater and ancillary equipment; Harmonised Standard for ElectroMagnetic Compatibility |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| ETSI EN 301 489-52 V1.3.1:2024 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 52:Specific conditions for Cellular Communication User Equipment (UE) radio and ancillary equipment; Harmonised Standard for ElectroMagnetic Compatibility |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
ETSI EN 301 489-1 V2.2.3:2019 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1:Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| ETSI EN 301 489-3 V2.3.2:2023 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3:Specific conditions for Short Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonised Standard for ElectroMagnetic Compatibility |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| ETSI EN 301 489-5 V2.3.1:2025 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 5:Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech) and Terrestrial Trunked Radio (TETRA); Harmonised Standard for ElectroMagnetic Compatibility |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
ETSI EN 301 489-9 V2.1.1:2019 |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 9:Specific conditions for wireless microphones, similar Radio Frequency (RF) audio link equipment, cordless audio and inear monitoring devices; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| FCC Part 15 |
Radio Frequency Devices Sub Part B Unintentional Radiators only |
RE : 30 MHz ~ 40 GHz CE : 150 kHz ~ 30 MHz |
소재지 |
| FCC Part 18 |
Industrial, Scientific and Medical Equipment |
RE : 30 MHz ~ 6 GHz CE : 150 kHz ~ 30 MHz |
소재지 |
| ICES-003:2016 |
Information Technology Equipment (Including Digital Apparatus) — Limits and Methods of Measurement |
RE : 30 MHz ~ 40 GHz CE : 150 kHz ~ 30 MHz |
소재지 |
| IEC 60945:2002 |
Maritime navigation and radio communication equipment and systems - General requirements - Methods of testing and required test results |
RE : 150 kHz ~ 2 GHz CE : 10 kHz ~ 30 MHz ESD : ±8 kV RS : 80 MHz ~ 2 GHz, 10 V/m EFT : ±2.0 kV Surge : ±1.0 kV CS : 150 kHz ~ 80 MHz, 10 V V-DIP : 0 ~ 100 % |
소재지 |
IEC 61000-3- 2:2018+AMD1:20 20 CSV |
Electromagnetic compatibility (EMC) - Part 3-2:Limits for harmonic current emissions (equipment input current ≤16 A per phase) |
1 phase equipment, ≤ 16 A |
소재지 |
IEC 61000-3- 3:2013+AMD1:20 17+AMD2:2021 CSV |
Electromagnetic compatibility (EMC) - Part 3-3:Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
1 phase equipment, ≤ 16 A |
소재지 |
IEC 61000-4- 11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11:Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
1 phase equipment, ≤ 16 A V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61000-4- 2:2008 |
Electromagnetic compatibility (EMC) - Part 4-2:Testing and measurement techniques - Electrostatic discharge immunity test |
ESD : ±30 kV |
소재지 |
IEC 61000-4- 3:2020 |
Electromagnetic compatibility (EMC) - Part 4-3:Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
RS : 80 MHz ∼ 6 GHz |
소재지 |
IEC 61000-4- 4:2012 |
Electromagnetic compatibility (EMC) — Part 4-4:Testing and measurement techniques - Electrical fast transient/burst immunity test |
EFT : ±4 ㎸ |
소재지 |
IEC 61000-4- 5:2014+AMD1:20 17 CSV |
Electromagnetic compatibility (EMC) - Part 4-5:Testing and measurement techniques - Surge immunity test |
1 phase equipment, ≤ 16 A Surge : ±4 kV |
소재지 |
| IEC 61000-4-6:2023 |
Electromagnetic compatibility (EMC) — Part 4-6:Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CS : 150 kHz ∼ 230 MHz |
소재지 |
IEC 61000-4- 8:2009 |
Electromagnetic compatibility (EMC) — Part 4-8:Testing and measurement techniques-Power frequency magnetic field immunity test |
M/F : 30 A/m |
소재지 |
IEC 61000-6- 1:2016 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and lightindustrial environments |
ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 3 V EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 3 A/m V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61000-6- 2:2016 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments |
ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 10 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61000-6- 3:2020 |
Electromagnetic compatibility (EMC) - Part 6-3:Generic standards - Emission standard for equipment in residential environments |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
IEC 61000-6- 4:2018 |
Electromagnetic compatibility (EMC) - Part 6-4:Generic standards - Emission standard for industrial environments |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
| IEC 61326-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1:General requirements |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61326-2- 1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1:Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61326-2- 2:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2:Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61326-2- 3:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3:Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61326-2- 4:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4:Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557- 8 and for equipment for insulation fault location according to IEC 61557- 9 |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
IEC 61326-2- 5:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5:Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784- 1 |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 30 A/m V-DIP : 0 ∼ 100 % |
소재지 |
| IEC 61547:2020 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD : ±8 kV RS : 80 MHz ∼ 1 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 3 A/m V-DIP : 0 ∼ 100 % |
소재지 |
| KN 60945_60533:2015 |
해상항해용 무선설비_항해 기기 및 선박용 전기전자기 기 전자파적합성 시험방법 |
RE : 150 kHz ~ 2 GHz CE : 10 kHz ~ 30 MHz ESD : ±8 kV RS : 80 MHz ~ 2 GHz, 10 V/m EFT : ±2.0 kV Surge : ±1.0 kV CS : 150 kHz ~ 80 MHz, 10 V V-DIP : 0 ~ 100 % |
소재지 |
| KS C 9547:2023 |
일반 조명기기 - 전자파적 합성(EMC) 내성 요구사항 |
ESD : ±15 kV RS : 80 MHz ∼ 1 GHz, 3 V/m EFT : ±1 kV Surge : ±4 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 3 A/m V-DIP : 0 ∼ 100 % |
소재지 |
KS C 9610-3- 2:2023 |
전자파적합성(EMC) - 제3- 2부:허용기준 - 고조파 전 류의 허용기준(상당 입력 전류 16A 이하 기기) |
1 phase equipment, ≤ 16 A |
소재지 |
KS C 9610-3- 3:2023 |
전자파적합성(EMC) - 제3- 3부:허용기준 - 공공 저압 배전망에 사용하는 기기의 플리커와 전압변동에 대한 허용기준(상당 16A 이하 기기) |
1 phase equipment, ≤ 16 A |
소재지 |
KS C 9610-4- 11:2020 |
전자파적합성(EMC) - 제4- 11부:시험 및 측정 기술 - 전압 강하, 순간 정전, 전압 변동 내성 시험 |
1 phase equipment, ≤ 16 A V-DIP : Max. 100 % |
소재지 |
KS C 9610-4- 2:2017 |
전자파적합성(EMC) - 제4- 2부:시험 및 측정 기술 - 정 전기 방전 내성 시험 |
ESD : Max. ±30 kV |
소재지 |
KS C 9610-4- 3:2017 |
전자파적합성(EMC) - 제4- 3부:시험 및 측정 기술 - 방 사성 RF 전자기장 내성 시 험 |
RS : 80 MHz ∼ 6 GHz |
소재지 |
KS C 9610-4- 4:2020 |
전자파적합성(EMC) - 제4- 4부:시험 및 측정 기술 - 전 기적 빠른 과도현상, 버스 트 내성 시험 |
1 phase equipment, ≤ 16 A EFT : Max. ±4 kV |
소재지 |
KS C 9610-4- 5:2023 |
전자파적합성(EMC) - 제4- 5부:시험 및 측정 기술 - 서 지 내성 시험 |
1 phase equipment, ≤ 16 A Surge : Max. ±4 kV |
소재지 |
KS C 9610-4- 6:2020 |
전자파적합성(EMC) - 제4- 6부:시험 및 측정 기술 - 전 도성 RF 전자기장 내성 시 험 |
1 phase equipment, ≤ 16 A 150 kHz ~ 230 MHz |
소재지 |
KS C 9610-4- 8:2017 |
전자파적합성(EMC) - 제4- 8부:시험 및 측정 기술 - 전 원 주파수 자기장 내성 시 험 |
M/F : Max. 30 A/m |
소재지 |
KS C 9610-6- 1:2019 |
전자파적합성(EMC) - 제6- 1부:일반표준 - 주거, 상업 및 경공업 환경에서 사용하 는 기기의 전자파 내성 표 준 |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±2 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 3 A/m V-DIP : 0 ~ 100 % |
소재지 |
KS C 9610-6- 2:2019 |
전자파적합성(EMC) - 제6- 2부:일반표준 - 산업 환경 에서 사용하는 기기의 전자 파 내성 표준 |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±2 kV SURGE : ±2 kV CS : 150 ㎑ ∼ 80 MHz, 10 V M/F : 30 A/m V-DIP : 0 ~ 100 % |
소재지 |
KS C 9610-6- 3:2023 |
전자파적합성(EMC) - 제6- 3부:일반기준 - 주거용, 상 업용 및 경공업 환경에서 사용하는 기기의 전자파 방 해 표준 |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
KS C 9610-6- 4:2022 |
전자파적합성(EMC) - 제6- 4부:일반표준 - 산업 환경 에서의 전자파 방출 표준 |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
| KS C 9811:2019 |
산업,과학,의료용(ISM) 기 기 - 무선 주파수 방해 특성 - 허용기준 및 측정방법 [제외항목] 2종 A급기기의 측정거리 30 m 방사성 방해 시험 |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 18 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
| KS C 9814-1:2022 |
전자파적합성(EMC) - 가정 용 전기기기, 전동 공구 및 유사기기의 요구사항 - 제 1부:방출 |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 1 GHz CE : 9 kHz ∼ 30 MHz |
소재지 |
| KS C 9814-2:2022 |
전자파적합성(EMC) - 가정 용 전기기기, 전동 공구 및 유사기기의 요구사항 - 제 2부:내성 |
1 phase equipment, ≤ 16 A ESD : ±30 kV RS : 80 MHz ∼ 6 GHz, 10 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 230 MHz, 3 V M/F : 10 A/m V-DIP : 0 ~ 100 % |
소재지 |
| KS C 9815:2023 |
조명기기 및 유사 기기의 무선 방해 특성 측정 허용 기준과 측정방법 [제외항목] 4.5.2 3 m, 4 m 루프안테 나 방사 |
1 phase equipment, ≤ 16 A RE : 9 kHz ∼ 1 GHz CE : 9 kHz ∼ 30 MHz |
소재지 |
| KS C 9832:2024 |
멀티미디어 기기 전자파 방 해 시험방법 |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
| KS C 9835:2019 |
멀티미디어 기기 전자파 내 성 시험방법 |
1 phase equipment, ≤ 16 A ESD : ±8 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±4 kV CS : 150 kHz ∼ 80 MHz, 3 V M/F : 1 A/m V-DIP : 0 ~ 100 % |
소재지 |
| QCVN 118:2018/BTTTT |
National technical regulation on Electromagnetic compatibility of multimedia equipment - Emission requirements |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz |
소재지 |
| QCVN 18:2022/BTTTT |
National technical regulation on Electromagnetic Compatibility for Radio Equipment |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| QCVN 86:2019/BTTTT |
National technical regulation on electromagnetic compatibility for mobile terminals and ancillary equipment of digital cellular telecommunication systems |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 2 700 MHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| QCVN 86:2025/BKHCN |
National technical regulation on electromagnetic compatibility for mobile terminals and ancillary equipment of digital cellular telecommunication systems |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| QCVN 96:2015/BTTTT |
National technical regulation on electromagnetic compatibility for Short Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| QCVN 112:2017/BTTTT |
National technical regulation on general electromagnetic compatibility for radio broadband data transmission equipment |
1 phase equipment, ≤ 16 A RE : 30 MHz ∼ 6 GHz CE : 150 kHz ∼ 30 MHz ESD : Air ±8 kV Contact ±4 kV RS : 80 MHz ∼ 6 GHz, 3 V/m EFT : ±1 kV Surge : ±2 kV CS : 150 kHz ∼ 80 MHz, 3 V V-DIP : 0 ~ 100 % |
소재지 |
| ▶ 에너지효율 |
| 기후에너지환경부 고시 제2026-137호, 효율관리기자재 운용규정 (2026.05.27) |
효율관리기자재 운용규정 제4조(효율관리 기자재의 지정 및 범위와 측정방법 등) ①의 20.(어댑터∙충전기) 26.(텔레비전수상기) 44.(모니터) 49.(컴퓨터) 50. (복합기) |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| 기후에너지환경부 고시 제2026-25호, 대기전력저감프로그램운용규정 (2026.01.23) |
대기전력저감 프로그램 운용규정 [제외항목] 제3조(대기전력저감 대상제품의 지정 등) ①의 19.(홈게이트웨이) |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| IEC 62301:2011(Ed.2.0) |
Household electrical appliances - Measurement of standby power |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| KS C IEC 62301:2011 |
가정용 전기기기의 대기전력 측정 방법 |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| IEC 62087-1:2015(Ed.1.0) |
Audio, video and related equipment - Determination of power consumption - Part1:General |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| KS C IEC 62087-1:2015 |
오디오, 비디오 및 관련 기기 - 전력 소비량의 결정(측정 방법) - 제1부:일반사항 |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| IEC 62087-2:2015(Ed.1.0) |
Audio, video and related equipment - Determination of power consumption - Part2:Signal and media |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| KS C IEC 62087-2:2015 |
오디오, 비디오 및 관련 기기 - 전력 소비량의 결정(측정 방법) - 제2부:신호와 미디어 |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| IEC 62087-3:2015(Ed.1.0) |
Audio, video and related equipment - Determination of power consumption - Part3: Television sets |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| KS C IEC 62087-3:2015 |
오디오, 비디오 및 관련 기기 - 전력 소비량의 결정(측정 방법) - 제3부:텔레비전 세트 |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| IEC 62087-4:2015(Ed.1.0) |
Audio, video and related equipment - Determination of power consumption - Part4: Video recording equipment |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| KS C IEC 62087-4:2015 |
오디오, 비디오 및 관련 기기 - 전력 소비량의 결정(측정 방법) - 제4부:비디오 녹화 장비 |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| IEC 62087-6:2015(Ed.1.0) |
Audio, video and related equipment - Determination of power consumption - Part6: Audio equipment |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| KS C IEC 62087-6:2015 |
오디오, 비디오 및 관련 기기 - 전력 소비량의 결정(측정 방법) - 제6부:오디오 장비 |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| IEC 62087-7:2018(Ed.1.0) |
Audio, video and related equipment - Determination of power consumption - Part7: Computer monitors |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |
| KS C IEC 62087-7:2018 |
오디오, 비디오 및 관련 기기 - 전력 소비량의 결정(측정 방법) - 제7부:컴퓨터 모니터 |
Input Voltage: Max. 300 V Input Current: Max. 15 A Input Wattage: Max. 5 000 W |
소재지 |