| ▶ 계측기기 |
| IEC 61010-1:2001 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
[Exception] 10.5.3: Insulating materials – Vicat (ISO 306 method A) 11.7: Fluid pressure and leakage 12.3: Ultraviolet(UV) radiation 12.4: Microwave radiation 12.5: Sonic and ultrasonic pressure 12.6: Laser sources 13: Protection against liberated gases, explosion and implosion |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| EN 61010-1:2010+A1:2019 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
[Exception] 10.5.3: Insulating materials – Vicat (ISO 306 method A) 11.7: Fluid pressure and leakage 12.3: Optical radiation 12.4: Microwave radiation 12.5: Sonic and ultrasonic pressure 12.6: Laser sources 13: Protection against liberated gases and substances, explosion and implosion Annex H: Qualification of conformal coatings for protection against POLLUTION |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 61010-1:2010+A1:2016 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
[Exception] 10.5.3: Insulating materials – Vicat (ISO 306 method A) 11.7: Fluid pressure and leakage 12.3: Optical radiation 12.4: Microwave radiation 12.5: Sonic and ultrasonic pressure 12.6: Laser sources 13: Protection against liberated gases and substances, explosion and implosion Annex H: Qualification of conformal coatings for protection against POLLUTION |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 61010-2-101:2018 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
[Exception] 12 Protection against radiation, including laser sources, and against sonic and ultrasonic pressure 13 Protection against liberated gases and substances, explosion and implosion |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity: Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 61010-2-101:2015 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
[Exception] 12 Protection against radiation, including laser sources, and against sonic and ultrasonic pressure 13 Protection against liberated gases and substances, explosion and implosion |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 61010-2-020:2006 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges
[Exception] Annex AA Dynamic microbiological test method for BIOSEALS |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 61010-2-020:2016 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges
[Exception] Annex AA Dynamic microbiological test method for BIOSEALS |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| EN 61010-2-020:2017 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges
[Exception] Annex AA Dynamic microbiological test method for BIOSEALS |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 61010-2-040:2005 |
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
[Exception] 13.1 Poisonous and injurious gases 13.101 Other HAZARDS arising from the use of toxic sterilants |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 250) N Pressure : (0 ∼ 500) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 61010-2-040:2020 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
[Exception] 13.1 Poisonous and injurious gases and substances 13.101 Other HAZARDS arising from the use of toxic sterilants |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 250) N Pressure : (0 ∼ 500) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| EN IEC 61010-2-040:2021 |
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
[Exception] 13.1 Poisonous and injurious gases and substances 13.101 Other HAZARDS arising from the use of toxic sterilants |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 250) N Pressure : (0 ∼ 500) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| ▶ 산업용 전기기기 |
| KC 60529:2015 |
외각에 따른 보호등급 분류(IP등급) |
Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 60529:1989+A1:1999+A2:2013 |
Degrees of protection provided by enclosures (IP Code)
[Exception] 6. Degrees of protection against ingress of water indicated by the second characteristic numeral: 9 Protected against high pressure and temperature water jets |
Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 60204-1:2016+A1:2021 |
Safety of machinery - Electrical equipment of machines - Part 1: General requirements 18.2.2 Test methods in TN-Systems Test 1 - Verification of the continuity of the protective bonding circuit 18.3 Insulation resistance tests 18.4 Voltage tests 18.5 Protection against residual voltages |
Earth continuity : Max AC 25 A Insulation resistance : Max 999 MΩ, DC 500 V Electric strength : Max AC 5 kV, 100 mA Residual voltage : Max 120 V |
소재지 |
| KS C IEC 60204-1:2016 |
기계류의 안전성 - 기계의 전기장비 - 제1부: 일반 요구사항 18.2.2 TN-시스템 시험방식 시험1-보호본딩 회로의 연속성 18.3 절연저항시험 18.4 전압시험 18.5 잔류전압보호 |
Earth continuity : Max AC 25 A Insulation resistance : Max 999 MΩ, DC 500 V Electric strength : Max AC 5 kV, 100 mA Residual voltage : Max 120 V |
소재지 |
| KS C IEC 60529:2013 |
외함의 밀폐 보호등급 구분(IP코드)
[제외] 6. 제 2 특성 숫자로 표시되는 방수 등급 : 제 2 특성 숫자 9 |
Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| ▶ 가정용 전기기기 |
| IEC 60335-2-43:2017 |
Household and similar electrical appliances - Safety - Part 2-43: Particular requirements for clothes dryers and towel rails |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| K 10003:2006 |
발욕조 및 이와 유사한 기기의 개별요구사항
[제외항목] 32 방사성, 유독성 및 이와 유사한 위험성 (오존 시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 10002:2006 |
반신욕조 및 이와 유사한 기기의 개별요구사항
[제외항목] 32 방사성, 유독성 및 이와 유사한 위험성(오존 시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-1:2020 |
Household and similar electrical appliances - Safety – Part 1: General requirements
[Exception] 22.16 Test for automatic cord reels 22.32 Oxygen bomb aging test for natural or synthetic rubber 22.46 Software evaluation 24 Components (test) Annex B 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F Capacitors (test) Annex H Switches (test) Annex J Coated printed circuit boards (test) Annex R Software evaluation Annex T UV-C radiation effect on non-metallic materials (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-1:2020+AMD1:2025 |
Household and similar electrical appliances - Safety – Part 1: General requirements
[Exception] 22.16 Test for automatic cord reels 22.32 Oxygen bomb aging test for natural or synthetic rubber 22.46 Software evaluation 24 Components (test) Annex B 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F Capacitors (test) Annex H Switches (test) Annex J Coated printed circuit boards (test) Annex R Software evaluation Annex T UV-C radiation effect on non-metallic materials (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-1:2010+A1:2013+A2:2016 |
Household and similar electrical appliances - Safety - Part 1: General requirements
[Exception] 22.16 Test for automatic cord reels 22.32 Oxygen bomb aging test for natural or synthetic rubber 22.46 Software evaluation 24 Components (test) Annex B 21.B.101 (Free fall test according to IEC 60068-2-31, Procedure 2) Annex F Capacitors (test) Annex H Switches (test) Annex J Coated printed circuit boards (test) Annex R Software evaluation Annex T UV-C radiation effect on non-metallic materials (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-1:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제1부: 일반 요구사항
[제외항목] 22.16 자동식 코드 릴 시험 22.32 천연고무 또는 합성고무에 대한 산소용기 노화시험 22.46 소프트웨어 평가 24 부품 (시험) 부속서 B 21.B.101 (IEC 60068-2-31, 절차 2에 따른 자유낙하 시험) 부속서 F 커패시터 (시험) 부속서 H 스위치 (시험) 부속서 J 코팅된 인쇄회로기판 (시험) 부속서 R 소프트웨어 평가 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-3:2022 |
Household and similar electrical appliances - Safety - Part 2-3: Particular requirements for electric irons |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-3:2022+AMD1:2025 |
Household and similar electrical appliances - Safety - Part 2-3: Particular requirements for electric irons, ironing boards, ironing systems and similar appliances |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-3:2012+A1:2015 |
Household and similar electrical appliances - Safety - Part 2-3: Particular requirements for electric irons |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-3:2016 |
가정용 및 이와 유사한 전기기기의 안전성 제2-3부: 전기다리미의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-8:2022 |
Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-8:2012+A1:2015+A2:2018 |
Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-8:2016 |
가정용 및 이와 유사한 전기기기의 안전성 제2-8부: 면도기, 이발기 및 이와 유사한 전기기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-9:2019 |
Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances
[Exception] 31 Resistance to rusting (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-9:2008+A1:2012+A2:2016 |
Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances
[Exception] 31 Resistance to rusting (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| K 60335-2-9:2013 |
가정용 및 이와 유사한 전기기기의 안전성 제2-9부: 그릴, 토스터기 및 이와 유사한 휴대용 조리 기기의 개별 요구사항
[제외항목] 31 내부식성 (시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-9:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-9부: 그릴, 토스터기 및 이와 유사한 휴대용 조리 기기의 개별 요구사항
[제외항목] 31 내부식성 (시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-21:2022 |
가정용 및 이와 유사한 전기기기의 안전성 - 제2-21부: 전기온수기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-21:2025 |
가정용 및 이와 유사한 전기기기의 안전성 - 제2-21부: 전기온수기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 10008:2011 |
가정용 및 이와 유사한 전기기기의 안전성 - 전기 이온수기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-28:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-28부: 전기재봉기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-28:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-28부: 전기재봉기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-28:2021 |
Household and similar electrical appliances – Safety – Part 2-28: Particular requirements for sewing machines |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-28:2002+A1:2008 |
Household and similar electrical appliances – Safety – Part 2-28: Particular requirements for sewing machines |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| K 10012:2013 |
가정용 및 이와 유사한 전기기기의 안전성 - 전기헬스기구 및 이와 유사한 기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-44:2021 |
가정용 및 이와 유사한 전기기기의 안전성 제2-44부 : 전기 주름 펴기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-49:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-49부: 상업용 전기 보온찬장의 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-43:2024 |
Household and similar electrical appliances - Safety - Part 2-43: Particular requirements for clothes dryers and towel rails |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-64:2021+A1:2024 |
Household and similar electrical appliances - Safety - Part 2-64: Particular requirements for commercial electric kitchen machines |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-21:2012+A1:2018 |
Household and similar electrical appliances - Safety - Part 2-21: Particular requirements for storage water heaters |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-32:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-32부: 전기 마사지 기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-32:2026 |
가정용 및 이와 유사한 전기기기의 안전성 제2-32부: 전기 마사지 기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-59:2021 |
Household and similar electrical appliances - Safety Parts 2-59: Particular requirements for insect killers
[Exception] 31 Resistance to rusting (test) 32 Radiation, toxicity and similar hazards (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-59:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-59부: 전기살충기의 개별 요구사항
[제외항목] 31 내부식성 (시험) 32 방사선, 유독성 및 이와 유사한 위험성 (시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-59:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-59부: 전기살충기의 개별 요구사항
[제외항목] 31 내부식성 (시험) 32 방사선, 유독성 및 이와 유사한 위험성 (시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-60:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-60부: 전기 기포 발생 욕조 및 이와 유사한 전기기기의 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-75:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-75부: 상업용 디스펜싱기기 및 자동판매기의 개별 요구사항
[제외항목] 부속서 AA 탄성체에 대한 노화 시험 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-75:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-75부: 상업용 디스펜싱기기 및 자동판매기의 개별 요구사항
[제외항목] 부속서 AA 탄성체에 대한 노화 시험 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 60335-2-85:2007 |
가정용 및 이와 유사한 전기 기기의 안전성 - 제2-85 부:직물용 전기 스티머에 대한 개별 요구 사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-98:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-98부: 전기 가습기의 개별요구 사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-98:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-98부: 전기 가습기의 개별요구 사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-100:2020 |
가정용 및 이와 유사한 전기기기의 안전성 제2-100부 : 수지형 (휴대용) 정원 송풍기 및 진공기(송풍기 및 진공기 겸용 포함)의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-102:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-102부: 전기를 사용하는 가스, 오일 및 고체연료 연소기기에 관한 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 70000:2008 |
가정용 및 이와 유사한 전기기기의 안전 - 전기소독기 및 이와 유사한 전기기기에 대한 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-37:2015 |
가정용 및 이와 유사한 전기 기기의 안전성 제2-37부: 상업용 전기 튀김기에 대한 개별 요구 사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-37:2025 |
가정용 및 이와 유사한 전기 기기의 안전성 제2-37부: 상업용 전기 튀김기에 대한 개별 요구 사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-36:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-36부 : 상업용 전기 조리레인지, 오븐, 호브 및 호브소자에 대한 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-35:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-35부 : 순간 온수기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-35:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-35부 : 순간 온수기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-26:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-26부: 전기 시계의 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-13:2016 |
가정용 및 이와 유사한 전기기기의 안전성 제2-13부:전기 튀김기, 전기 프라이팬 및 이와 유사한 기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-12:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-12부: 보온 플레이트 및 이와 유사한 기기의 개별 요구 사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-12:2026 |
가정용 및 이와 유사한 전기기기의 안전성 제2-12부: 보온 플레이트 및 이와 유사한 기기의 개별 요구 사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-6:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-6부: 거치형 조리레인지, 호브, 오븐 및 이와 유사한 기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 10029:2020 |
가정용 및 이와 유사한 전기기기의 안전성 - 전기 모기채의 개별 요구 사항 |
입력전압 : 최대 DC 42 V 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 내전압: 5 kV 습도 : 최대 95 % R.H. |
소재지 |
| K 10013:2008 |
가정용 및 이와 유사한 전기기기의 안전성 - 수도동결방지기 및 이와 유사한 유연성을 가진 전열기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 10010:2008 |
가정용 및 이와 유사한 전기기기의 안전성 - 새싹 및 콩나물 재배기 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-21:2022 |
Household and similar electrical appliances - Safety - Part 2-21: Particular requirements for storage water heaters |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-49:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-49부: 상업용 전기 보온찬장의 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-55:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-55부: 수족관 및 정원연못용 전기기기의 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-14:2025 |
Household and similar electrical appliances - Safety - Part 2-14: Particular requirements for kitchen machines
[Exception] 25.7 Tests of 4.2 and 4.3 of IEC 60811-504:2012 and 4.2 of IEC 60811-505:2012 |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-23:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-23부: 피부 손질 또는 모발 손질용 전기기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 10015:2008 |
가정용 및 이와 유사한 전기기기의 안전성 - 물수건 마는기기 및 이와 유사한 기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 10007:2008 |
가정용 및 이와 유사한 전기기기의 안전성 - 전기 정수기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-54:2008+A1:2015+A2:2019 |
Household and similar electrical appliances - Safety - Part 2-54: particular requirements for surface-cleaning appliances for household use employing liquids or steam
[Exception] 21.101 Crushing test of current-carrying hoses 21.102 Abrasion test of current-carrying hoses 21.103 Flexing test of current-carrying hoses 21.104 Torsion test of current-carrying hoses 21.105 Low temp. test of current-carrying hoses |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-43:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-43부: 의류 건조기 및 타월걸이의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-43:2002+A1:2005+A2:2008 |
Household and similar electrical appliances - Safety - Part 2-43: Particular requirements for clothes dryers and towel rails |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-70:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-70부: 전기 착유기의 개별요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 60950-1(2.0):2011 |
정보 기술기기 - 안전 제1부 : 일반 요구사항
[제외] 1.5.6 절연 가교 캐패시터 (시험) 1.5.9 서지 억제기 (시험) 2.8.7.2 과부하 시험 2.8.7.3 내구성 시험 2.10.8.4 내마모성시험 3.2.5.1 교류주전원 코드 4.2.8 브라운관 4.2.9 고압램프 4.3.10 4.3.12항의 시험 4.3.12 가연성액체시험 4.3.13 방사시험 (UV시험) 4.3.13.5 레이저시험 (LED시험 포함) 4.6.2 A.3절의 시험 부속서 A.3 점화유시험 부속서 K 온도조절기시험 부속서 Y 자외선처리시험 부속서 AA 맨드렐시험 부속서 CC 통합회로(IC) 과전류 보호장치의 평가 |
입력: 300 V, 20 A 측정 전압 : 20 kV a.c. / 20 kV d.c. 측정 주파수 : 400 MHz 측정 전력: 24 kW 측정 정전량 : 10 mF 측정 토크 : (1 ~ 14.5) Ncm 누설전류 : 최대 10 mA 측정 온도 : 최대 200 ℃ 전기적 내력 : 5 kV, 100 mA 습도 : 최대 95 % R.H. 접지연속성 : 6 V, 60 A 힘: (1 ~ 50) N 압력: (0 - 150) kPa 강수량 : (1 ~ 3) mm/min 유수량 : (0.07 ~ 100) L/min 침수높이 : (0.15 ~ 1) m |
소재지 |
| KC 60335-2-54:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-54부: 액체 또는 증기사용 가정용 표면 청소기의 개별 요구사항
[제외항목] 21.101 통전호스의 압착시험 21.102 통전호스의 마모시험 21.103 통전호스의 굽힘시험 21.104 통전호스의 비틀림시험 21.105 통전호스의 저온시험 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-32:2019 |
Household and similar electrical appliances - Safety - Part 2-32: Particular requirements for massage appliances |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-64:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-64부 : 상업용 전기주방기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-64:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-64부 : 상업용 전기주방기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-80:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-80부: 전기 팬(fan)의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-23:2016+A1:2019 |
Household and similar electrical appliances - Safety - Part 2-23: Particular requirements for appliances for skin or hair care |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-23:2026 |
Household and similar electrical appliances - Safety - Part 2-23: Particular requirements for hair care and similar appliances |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-32:2024 |
Household and similar electrical appliances - Safety - Part 2-32: Particular requirements for massage appliances |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-32:2002+A1:2008+A2:2013 |
Household and similar electrical appliances - Safety - Part 2-32: Particular requirements for massage appliances |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-80:2024 |
Household and similar electrical appliances - Safety - Part 2-80: Particular requirements for fans |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-80:2015 |
Household and similar electrical appliances - Safety - Part 2-80: Particular requirements for fans |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-65:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-65부: 공기 청정기의 개별 요구사항
[제외항목] 32 방사선, 유독성 및 이와 유사한 위험성 (오존 시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-65:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-65부: 공기 청정기의 개별 요구사항
[제외항목] 32 방사선, 유독성 및 이와 유사한 위험성 (오존 시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-65:2002+A1:2008+A2:2015 |
Household and similar electrical appliances – Safety – Part 2-65: Particular requirements for air-cleaning appliances
[Exception] 23.101 Internal wiring (Condition testing of internal wiring according to Annex AA) 32.101 Radiation, Toxicity and similar hazard (Ozone test) 32.102 Radiation, Toxicity and similar hazard (Measuring emit radiation in hazardous amount) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-65:2023 |
Household and similar electrical appliances – Safety – Part 2-65: Particular requirements for air-cleaning appliances
[Exception] 32.101 Radiation, Toxicity and similar hazard (Ozone test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-14:2016+A1:2019 |
Household and similar electrical appliances - Safety - Part 2-14: Particular requirements for kitchen machines
[Exception] 25.7 Tests of 4.2 and 4.3 of IEC 60811-504:2012 and 4.2 of IEC 60811-505:2012 |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60950-1:2005+A1:2009+A2:2013 |
Information technology equipment - Safety - Part 1: General requirements
[Exception] 1.5.6 Capacitors bridging insulation (Test) 1.5.9 Surge suppressors (Test) 2.8.7.2 Overload test 2.8.7.3 Endurance test 2.10.8.4 Abrasion resistance test 3.2.5.1 AC power supply cords 4.2.8 Cathode ray tube 4.2.9 High pressure lamps 4.3.10 Tests of 4.3.12 4.3.12 Flammable liquids test 4.3.13 Radiation test (UV Test) 4.3.13.5 Lasers test (Including LED test) 4.6.2 Tests of Clause A.3 Annex A.3 Hot Flamming oil test Annex K Thermal controls test Annex Y UV Test Annex AA Mandrel test Annex CC Evaluation of integrated circuit (IC) current limiters |
Input: 300 V, 20 A, Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring frequency : 400 MHz Measuring power : 24 kW Measuring capacitance : 10 mF Measuring torque : (1 ~ 14.5) Ncm Leakage Current : Max. 10 mA Measuring temperature : Max. 200 ℃ Electric strength : 5 kV, 100 mA Humidity : Max. 95 % R.H. Earth continuity : 6 V, 60 A Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| KC 60335-2-101:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-101부: 전기 훈증기에 관한 개별 요구사항
[제외항목] 21.101 자유낙하시험 (IEC 60068-2-32, 절차 2) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-64:2021 |
Household and similar electrical appliances - Safety - Part 2-64: Particular requirements for commercial electric kitchen machines |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| K 10016:2008 |
가정용 및 이와 유사한 전기기기의 안전성 - 물수건 포장기기 및 이와 유사한 기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-14:2016 |
가정용 및 이와 유사한 전기기기의 안전성 제2-14부: 주방기기의 개별 요구사항
[제외항목] 25.7 KS C IEC 60811-504:2014의 4.2, 4.3 및 KS C IEC 60811-505:2014 4.2의 시험 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 60335-2-14:2025 |
가정용 및 이와 유사한 전기기기의 안전성 제2-14부: 주방기기의 개별 요구사항
[제외항목] 25.7 KS C IEC 60811-504:2014의 4.2, 4.3 및 KS C IEC 60811-505:2014 4.2의 시험 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-15:2024 |
Household and similar electrical appliances - Safety - Part 2-15: Particular requirements for appliances for heating liquids |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-15:2012+A1:2016+A2:2018 |
Household and similar electrical appliances - Safety - Part 2-15: Particular requirements for appliances for heating liquids |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-54:2022 |
Household and similar electrical appliances - Safety - Part 2-54: particular requirements for surface-cleaning appliances for household use employing liquids or steam
[Exception] 21.101 Crushing test of current-carrying hoses 21.102 Abrasion test of current-carrying hoses 21.103 Flexing test of current-carrying hoses 21.104 Torsion test of current-carrying hoses 21.105 Low temp. test of current-carrying hoses |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-54:2022+AMD1:2025 |
Household and similar electrical appliances - Safety - Part 2-54: particular requirements for surface-cleaning appliances for household use employing liquids or steam
[Exception] 21.101 Crushing test of current-carrying hoses 21.102 Abrasion test of current-carrying hoses 21.103 Flexing test of current-carrying hoses 21.104 Torsion test of current-carrying hoses 21.105 Low temp. test of current-carrying hoses |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-15:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-15부: 액체가열용 전기기기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 62368-1:2014 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.4.6.5 Mandrel test 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex C UV radiation Annex G.7 Test according to IEC 60227 Annex G.9 Integrated circuit (IC) current limiters Annex G.10 Test according to IEC 60068-2-78 Annex G.13.6.2 Test method and compliance criteria (test) Annex G.15.3.1 Hydrostatic pressure test Annex G.15.3.3 Tubing and fittings compatibility test Annex J Test according to IEC 60851-3 and IEC 60851-5 Annex M.8.2 Protection against internal ignition from external spark sources – Spark Test Annex R Limited Short-circuit test Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Mechanical strength of CRTs and protection against the effects of implosion |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : Max. 5 kV Insulation resistance : Max. 4 000 ㏁ Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 62368-1:2023 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.4.6.5 Mandrel test 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex G.5.3.4 Test for FIW Annex G.7 Test according to IEC 60227 Annex G.9 Integrated circuit (IC) current limiters Annex G.10 Test according to IEC 60068-2-78 Annex G.13.6.2 Test method and compliance criteria (test) Annex G.15.3.1 Hydrostatic pressure test Annex G.15.3.3 Tubing and fittings compatibility test Annex J Test according to IEC 60851-3 and IEC 60851-5 Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8.2 Protection against internal ignition from external spark sources – Spark Test Annex R Limited Short-circuit test Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.2 Ultraviolet light conditioning test Annex Y.3 Construction requirements for outdoor enclosures (test) Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression test Annex Y.4.5 Oil resistance (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : Max. 5 kV Insulation resistance : Max. 4 000 ㏁ Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| EN 62368-1:2014+A11:2017 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.4.6.5 Mandrel test 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex C UV radiation Annex G.7 Test according to IEC 60227 Annex G.9 Integrated circuit (IC) current limiters Annex G.10 Test according to IEC 60068-2-78 Annex G.13.6.2 Test method and compliance criteria (test) Annex G.15.3.1 Hydrostatic pressure test Annex G.15.3.3 Tubing and fittings compatibility test Annex J Test according to IEC 60851-3 and IEC 60851-5 Annex M.8.2 Protection against internal ignition from external spark sources – Spark Test Annex R Limited Short-circuit test Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Mechanical strength of CRTs and protection against the effects of implosion |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : Max. 5 kV Insulation resistance : Max. 4 000 ㏁ Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| EN IEC 62368-1:2020+A11:2020 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.4.6.5 Mandrel test 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex G.5.3.4 Test for FIW Annex G.7 Test according to IEC 60227 Annex G.9 Integrated circuit (IC) current limiters Annex G.10 Test according to IEC 60068-2-78 Annex G.13.6.2 Test method and compliance criteria (test) Annex G.15.3.1 Hydrostatic pressure test Annex G.15.3.3 Tubing and fittings compatibility test Annex J Test according to IEC 60851-3 and IEC 60851-5 Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8.2 Protection against internal ignition from external spark sources – Spark Test Annex R Limited Short-circuit test Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.2 Ultraviolet light conditioning test Annex Y.3 Construction requirements for outdoor enclosures (test) Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression test Annex Y.4.5 Oil resistance (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : Max. 5 kV Insulation resistance : Max. 4 000 ㏁ Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-101:2015 |
가정용 및 이와 유사한 전기기기의 안전성 제2-101부: 전기 훈증기에 관한 개별 요구사항
[제외항목] 21.101 자유낙하시험 (IEC 60068-2-32, 절차 2) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-101:2024 |
Household and similar electrical appliances - Safety - Part 2-101: Particular requirements for vaporizers
[Exception] 21.101 Free-fall test (IEC 60068-2-31, procedure 2) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-101:2002+A1:2008+A2:2014 |
Household and similar electrical appliances - Safety - Part 2-101: Particular requirements for vaporizers
[Exception] 21.101 Free-fall test (IEC 60068-2-31, procedure 2) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 60335-2-82:2022 |
가정용 및 이와 유사한 전기기기의 안전성 제2-82부: 오락기기 및 개인용 서비스기기의 개별 요구사항
[제외항목] 31 내부식성 (시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력 : 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-82:2002+A1:2008+A2:2015 |
Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines
[Exception] 31 Resistance to rusting (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| KC 62368-1:2025 |
오디오/비디오 및 정보통신기술기기 제1부 : 안전 요구 사항
[제외항목] 5.4.1.10.2 KS M ISO 306의 연화온도(Vicat) 시험 B50 5.4.4.6.5 맨드릴(mandrel) 시험 5.6.4.1 과전류 보호수단 및 회로의 결정 (부속서 R) 10 방사(선) (레이저 (레이저 다이오드 포함), 발광다이오드 (LED), 재질에 대한 자외선 방사의 영향 (부속서 C), 자외선 방사에 인체 노출 (부속서 C), 음향) 부속서 G.5.3.4 FIW 시험 부속서 G.7 KS C IEC 60227에 따른 시험 부속서 G.9 집적회로(IC) 전류 제한기 부속서 G.10 IEC 60068-2-78에 따른 시험 부속서 G.13.6.2 시험방법 및 적합성 기준 (시험) 부속서 G.15.2.1 수압 시험 부속서 G.15.2.3 튜빙 및 피팅 호환성 시험 부속서 J IEC 60851-3 및 IEC 60851-5에 따른 시험 부속서 M.7 납축전지 및 니켈-카드뮴 배터리의 폭발 위험 부속서 M.8.2 외부 스파크 원으로부터 내부 점화에 대한 보호 – 스파크 시험 부속서 R 제한 단락 회로 시험 부속서 S 내열 및 내화성 시험 - 부속서 S.3.2에 기술된 증류 연료 오일 부속서 U CRTs의 기계적 강도 및 내파 영향에 대한 보호 부속서 Y.2 자외선 처리 시험 부속서 Y.3 옥외용 엔클로우저 구성 요구 사항 (시험) 부속서 Y.4.3 인장강도 및 연신율 시험 부속서 Y.4.4 압축 시험 부속서 Y.4.5 내유성 (시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 절연저항 : 최대 4 000 ㏁ 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| KC 62368-1:2021 |
오디오/비디오 및 정보통신기술기기 제1부 : 안전 요구 사항
[제외항목] 5.4.1.10.2 KS M ISO 306의 연화온도(Vicat) 시험 B50 5.4.4.6.5 맨드릴(mandrel) 시험 5.6.4.1 과전류 보호수단 및 회로의 결정 (부속서 R) 10 방사(선) (레이저 (레이저 다이오드 포함), 발광다이오드 (LED), 재질에 대한 자외선 방사의 영향 (부속서 C), 자외선 방사에 인체 노출 (부속서 C), 음향) 부속서 G.5.3.4 FIW 시험 부속서 G.7 KS C IEC 60227에 따른 시험 부속서 G.9 집적회로(IC) 전류 제한기 부속서 G.10 IEC 60068-2-78에 따른 시험 부속서 G.13.6.2 시험방법 및 적합성 기준 (시험) 부속서 G.15.2.1 수압 시험 부속서 G.15.2.3 튜빙 및 피팅 호환성 시험 부속서 J IEC 60851-3 및 IEC 60851-5에 따른 시험 부속서 M.7 납축전지 및 니켈-카드뮴 배터리의 폭발 위험 부속서 M.8.2 외부 스파크 원으로부터 내부 점화에 대한 보호 – 스파크 시험 부속서 R 제한 단락 회로 시험 부속서 S 내열 및 내화성 시험 - 부속서 S.3.2에 기술된 증류 연료 오일 부속서 U CRTs의 기계적 강도 및 내파 영향에 대한 보호 부속서 Y.2 자외선 처리 시험 부속서 Y.3 옥외용 엔클로우저 구성 요구 사항 (시험) 부속서 Y.4.3 인장강도 및 연신율 시험 부속서 Y.4.4 압축 시험 부속서 Y.4.5 내유성 (시험) |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 절연저항 : 최대 4 000 ㏁ 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| K 10009:2008 |
가정용 및 이와 유사한 전기기기의 안전성 - 초음파세척기의 개별 요구사항 |
입력 전압 : 최대 500 V 입력 주파수 : (50/60) Hz 누설전류 : 최대 10 mA 온도 : 최대 200 ℃ 절연내력: 5 kV 습도 : 최대 95 % R.H. 접지연속성 : 4 V, 300 A |
소재지 |
| IEC 60335-2-82:2024 |
Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines
[Exception] 31 Resistance to rusting (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| IEC 60335-2-82:2017+A1:2020 |
Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines
[Exception] 31 Resistance to rusting (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : 5 kV Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| EN IEC 62368-1:2024+A11:2024 |
Audio/video, information and communication technology equipment - Part 1: Safety requirements
[Exception] 5.4.1.10.2 Vicat test B 50 of ISO 306 5.4.4.6.5 Mandrel test 5.6.4.1 Determination of the overcurrent protective device and circuit (Annex R) 10 Radiations (Laser (including laser diodes), Light emitting diodes (LEDs), Effect of UV radiation on materials (Annex C), Human exposure to UV radiation (Annex C), Acoustics) Annex G.5.3.4 Test for FIW Annex G.7 Test according to IEC 60227 Annex G.9 Integrated circuit (IC) current limiters Annex G.10 Test according to IEC 60068-2-78 Annex G.13.6.2 Test method and compliance criteria (test) Annex G.15.3.1 Hydrostatic pressure test Annex G.15.3.3 Tubing and fittings compatibility test Annex J Test according to IEC 60851-3 and IEC 60851-5 Annex M.7 Risk of explosion from lead acid and NiCd batteries Annex M.8.2 Protection against internal ignition from external spark sources – Spark Test Annex R Limited Short-circuit test Annex S Tests for resistance to heat and fire - Distillate fuel oil as described in annex S.3.2 Annex U Mechanical strength of CRTs and protection against the effects of implosion Annex Y.2 Ultraviolet light conditioning test Annex Y.3 Construction requirements for outdoor enclosures (test) Annex Y.4.3 Tensile strength and elongation tests Annex Y.4.4 Compression test Annex Y.4.5 Oil resistance (test) |
Input voltage : Max. 500 V Input frequency : (50/60) Hz Leakage current : Max. 10 mA Temperature : Max. 200 ℃ Electric strength : Max. 5 kV Insulation resistance : Max. 4 000 ㏁ Humidity : Max. 95 % R.H. Earth continuity : 4 V, 300 A |
소재지 |
| ▶ 의료기기 |
| EN IEC 60601-2-28:2019 |
Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring temperature : Max. 400 ℃ |
소재지 |
| EN IEC 60601-2-22:2020 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
Measuring distance : 2 000 mm Measuring time : 1/100 s Laser power : 500 pW to 500 W Laser energy : 20 μJ to 600 J Measuring wavelength : 200 nm to 2 500 nm |
소재지 |
| EN IEC 60601-2-22:2020+A11:2026 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
Measuring distance : 2 000 mm Measuring time : 1/100 s Laser power : 500 pW to 500 W Laser energy : 20 μJ to 600 J Measuring wavelength : 200 nm to 2 500 nm |
소재지 |
| IEC 60601-2-28:2017 |
Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring temperature : Max. 400 ℃ |
소재지 |
| IEC 60601-2-44:2009+A1:2012+A2:2016 |
Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring time : 1/100 s Measuring angle : 0° ~ 360° Measuring weight : 0 kg ~ 150 kg Measuring radiation dose : 0.03 uR ~ 144 kR |
소재지 |
| EN 60601-2-44:2009+A2:2016 |
Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring time : 1/100 s Measuring angle : 0° ~ 360° Measuring weight : 0 kg ~ 150 kg Measuring radiation dose : 0.03 uR ~ 144 kR |
소재지 |
| IEC 60601-2-10:2012+A1:2016+A2:2023 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring frequency : 500 MHz Measuring distance : 2 m Measuring time : 1/100 s |
소재지 |
| IEC 60601-2-57:2011 |
Medical electrical equipment - Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use |
- |
소재지 |
| IEC 60601-2-57:2023 |
Medical electrical equipment - Part 2-57: Particular requirements for the basic safety and essential performance of non-laser light source equipment intended for therapeutic, diagnostic, monitoring and cosmetic/aesthetic use |
- |
소재지 |
| IEC 60601-2-63:2012+A1:2017+A2:2021 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring tube voltage : (40 ~ 150) kV Measuring tube current : (10 ~ 2 000) mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h |
소재지 |
| EN 60601-2-28:2010 |
Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring temperature : Max. 400 ℃ |
소재지 |
| EN 60601-1:2006+A1:2013+A12:2014+A2:2021 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
[Exception] 8.8.4.2 Resistance to environmental stress 9.4.2.4.2 Force for propulsion 9.5 Expelled parts HAZARD 9.6.3 Hand-transmitted vibration 9.7 Pressure vessels and parts subject to pneumatic and hydraulic pressure 10.3 Microwave radiation 10.4 Lasers 11.2.2 ME EQUIPMENT and ME SYSTEMS used in conjunction with OXYGEN RICH ENVIRONMENTS 11.3 Constructional requirements for fire ENCLOSURES of ME EQUIPMENT a) 11.6.7 Sterilization of ME EQUIPMENT and ME SYSTEMS 15.4.3.4 Lithium batteries 15.4.7.3 Entry of liquids 16.9.2 MAINS PARTS, components and layout Annex G(normative) Protection against HAZARDS of ignition of flammable anaesthetic mixtures Annex L(normative) Insulated winding wires for use without interleaved insulation |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring frequency : 500 MHz Measuring power : 1 MVA Measuring distance : 2 m Measuring temperature : Max. 400 °C Measuring resistance : 40 MΩ Measuring capacitance : 1 F Measuring time : 1/100 s Measuring humidity : Max. 98 % R.H. Measuring angle : 0° ~ 360° Measuring torque : 10 N·m Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
EN 60601-1:2006+A1:2013+A12:2014+A2:2021 +A13:2024 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
[Exception] 8.8.4.2 Resistance to environmental stress 9.4.2.4.2 Force for propulsion 9.5 Expelled parts HAZARD 9.6.3 Hand-transmitted vibration 9.7 Pressure vessels and parts subject to pneumatic and hydraulic pressure 10.3 Microwave radiation 10.4 Lasers 11.2.2 ME EQUIPMENT and ME SYSTEMS used in conjunction with OXYGEN RICH ENVIRONMENTS 11.3 Constructional requirements for fire ENCLOSURES of ME EQUIPMENT a) 11.6.7 Sterilization of ME EQUIPMENT and ME SYSTEMS 15.4.3.4 Lithium batteries 15.4.7.3 Entry of liquids 16.9.2 MAINS PARTS, components and layout Annex G(normative) Protection against HAZARDS of ignition of flammable anaesthetic mixtures Annex L(normative) Insulated winding wires for use without interleaved insulation |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring frequency : 500 MHz Measuring power : 1 MVA Measuring distance : 2 m Measuring temperature : Max. 400 °C Measuring resistance : 40 MΩ Measuring capacitance : 1 F Measuring time : 1/100 s Measuring humidity : Max. 98 % R.H. Measuring angle : 0° ~ 360° Measuring torque : 10 N·m Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 60601-2-28:2010 |
Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring temperature : Max. 400 ℃ |
소재지 |
| IEC 60601-1-11:2015+A1:2020 |
Medical electrical equipment – Part 1-11: General requirements for basic safety and essential performance – Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
[Exception] 10.1.2 Requirements for mechanical strength for non-TRANSIT -OPERABLE ME EQUIPMENT 10.1.3 Requirements for mechanical strength for TRANSIT -OPERABLE ME EQUIPMENT 13.1 Additional requirement for generation of ALARM SIGNALS 13.2 Additional requirement for ALARM SIGNAL volume |
Measuring temperature of humidity : Min. -40 °C Measuring temperature : Max. 150 °C Measuring humidity : Max. 98 % R.H. Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| EN 60601-1-11:2015 +A1:2021 |
Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
[Exception] 10.1.2 Requirements for mechanical strength for non-TRANSIT -OPERABLE ME EQUIPMENT 10.1.3 Requirements for mechanical strength for TRANSIT -OPERABLE ME EQUIPMENT 13.1 Additional requirement for generation of ALARM SIGNALS 13.2 Additional requirement for ALARM SIGNAL volume |
Measuring temperature of humidity: Min. -40 °C Measuring temperature : Max. 150 °C Measuring humidity : Max. 98 % R.H. Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 60601-2-2:2009 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
[Exception] 201.8.4.102 Neuromuscular stimulation 201.8.10.4.2 Connection cords 201.15.101.5 NE thermal performance 201.15.101.7 NE adhesion |
Input: 300 V, 20 A Measuring frequency : 400 MHz Leakage current : Max. 10 mA Electric strength : 5 kV, 100 mA |
소재지 |
| IEC 60601-2-2:2017+A1:2023 |
Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
[Exception] 201.8.4.102 Neuromuscular stimulation 201.8.10.4.2 Connection cords 201.15.101.5 NE thermal performance 201.15.101.7 NE adhesion |
Input: 300 V, 20 A Measuring frequency : 400 MHz Leakage current : Max. 10 mA Electric strength : 5 kV, 100 mA |
소재지 |
| IEC 60601-2-5:2009 |
Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment
[Exception] 201.10.102 Unwanted ultrasound radiation 201.12.1.101 Output power measurements 201.12.4.4 Incorrect output 201.12.4.4.102 Output stability with supply variations 201.12.4.4.104 Homogeneity of the radiation field 201.12.4.4.105 Output stability with time |
Measuring temperature : (0 ~ 200) ℃ |
소재지 |
| EN 60601-2-10:2015+A1:2016 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring frequency : 500 MHz Measuring distance : 2 m Measuring time : 1/100 s |
소재지 |
| EN 60601-2-10:2015+A2:2024 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring frequency : 500 MHz Measuring distance : 2 m Measuring time : 1/100 s |
소재지 |
| IEC 60601-2-22:2012 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
Measuring distance : 2 000 mm Measuring time : 1/100 s Laser power : 500 pW to 500 W Laser energy : 20 μJ to 600 J Measuring wavelength : 200 nm to 2 500 nm |
소재지 |
| IEC 60601-2-22:2019 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
Measuring distance : 2 000 mm Measuring time : 1/100 s Laser power : 500 pW to 500 W Laser energy : 20 μJ to 600 J Measuring wavelength : 200 nm to 2 500 nm |
소재지 |
| IEC 60601-2-22:2019+AMD1:2026 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
Measuring distance : 2 000 mm Measuring time : 1/100 s Laser power : 500 pW to 500 W Laser energy : 20 μJ to 600 J Measuring wavelength : 200 nm to 2 500 nm |
소재지 |
| IEC 60601-2-54:2009+A1:2015 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring time : 1/100 s Measuring angle : 0° ~ 360° Measuring weight : 0 kg ~ 150 kg Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h Measuring luminance : 200 000 lx |
소재지 |
| IEC 60601-2-54:2009+A2:2018 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring time : 1/100 s Measuring angle : 0° ~ 360° Measuring weight : 0 kg ~ 150 kg Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h Measuring luminance : 200 000 lx |
소재지 |
| EN 60601-2-54:2009+A1:2015+A2:2019 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring time : 1/100 s Measuring angle : 0° ~ 360° Measuring weight : 0 kg ~ 150 kg Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h Measuring luminance : 200 000 lx |
소재지 |
| EN IEC 60601-2-54:2024 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring time : 1/100 s Measuring angle : 0° ~ 360° Measuring weight : 0 kg ~ 150 kg Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h Measuring luminance : 200 000 lx |
소재지 |
| IEC 60601-2-54:2022 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring time : 1/100 s Measuring angle : 0° ~ 360° Measuring weight : 0 kg ~ 150 kg Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h Measuring luminance : 200 000 lx |
소재지 |
| IEC 60601-1:2005+A1:2012+A2:2020 |
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
[Exception] 8.8.4.2 Resistance to environmental stress 9.4.2.4.2 Force for propulsion 9.5 Expelled parts HAZARD 9.6.3 Hand-transmitted vibration 9.7 Pressure vessels and parts subject to pneumatic and hydraulic pressure 10.3 Microwave radiation 10.4 Lasers 11.2.2 ME EQUIPMENT and ME SYSTEMS used in conjunction with OXYGEN RICH ENVIRONMENTS 11.3 Constructional requirements for fire ENCLOSURES of ME EQUIPMENT a) 11.6.7 Sterilization of ME EQUIPMENT and ME SYSTEMS 15.4.3.4 Lithium batteries 15.4.7.3 Entry of liquids 16.9.2 MAINS PARTS, components and layout Annex G(normative) Protection against HAZARDS of ignition of flammable anaesthetic mixtures Annex L(normative) Insulated winding wires for use without interleaved insulation |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring frequency : 500 MHz Measuring power : 1 MVA Measuring distance : 2 m Measuring temperature : Max. 400 °C Measuring resistance : 40 MΩ Measuring capacitance : 1 F Measuring time : 1/100 s Measuring humidity : Max. 98 % R.H. Measuring angle : 0° ~ 360° Measuring torque : 10 N·m Force: (1 ∼ 50) N Pressure : (0 ∼ 150) kPa Rainfall rate : (1 ∼ 3) ㎜/min Water flow rate : (0.07 ∼ 100) L/min Immersion height : (0.15 ∼ 1) m |
소재지 |
| IEC 60601-1-6:2010+A1:2013+A2:2020 |
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability |
- |
소재지 |
| IEC 80601-2-26:2019+A1:2024 |
Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs |
Measuring voltage : 5 kV a.c. / 5 kV d.c. Measuring frequency : (0 ~ 60) Hz |
소재지 |
| IEC 80601-2-26:2019 |
Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs |
Measuring voltage : 5 kV a.c. / 5 kV d.c. Measuring frequency : (0 ~ 60) Hz |
소재지 |
| IEC 60601-2-26:2012 |
Medical electrical equipment - Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs |
Measuring voltage : 5 kV a.c. / 5 kV d.c. Measuring frequency : (0 ~ 60) Hz |
소재지 |
| EN 60601-2-65:2013+A1:2020+A2:2021 |
Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h |
소재지 |
| IEC 60601-2-65:2012+A1:2017+A2:2021 |
Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h |
소재지 |
| EN 60601-2-63:2015+A1:2019+A2:2021 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
Measuring voltage : 20 kV a.c. / 20 kV d.c. Measuring current : 1 000 A Measuring resistance : 40 MΩ Measuring distance : 2 m Measuring tube voltage : (40 ~ 150) kV Measuring tube current : 10 mA ~ 2 000 mA Measuring tube exposure time : 0.2 ms ~ 300 s Measuring tube current time product : (0.1 ~ 20 000.0) mAs Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h |
소재지 |
| IEC 60601-1-3:2008+A1:2013+A2:2021 |
Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Measuring distance : 2 m Measuring tube voltage : (40 ~ 150) kV Measuring luminance : 200 000 lx Measuring radiation dose : 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h |
소재지 |
| EN 60601-1-3:2008+A11:2016+A2:2021 |
Medical electrical equipment - Part 1-3: General requirements for basic safety and essential performance - Collateral standard: Radiation protection in diagnostic X-ray equipment |
Measuring distance : 2 m Measuring tube voltage: (40 ~ 150) kV Measuring luminance : 200 000 lx Measuring radiation dose: 50 nGy ~ 50 Gy Measuring radiation dose rate : 0.1 mR/h ~ 65 R/h |
소재지 |
| ▶ 전자기적합성 |
| EN 60601-2-47:2015 |
Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-5:2019 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-5부: 특정 요건 - IEC 61784-1, CP 3/2에 따른 인터페이스를 장착한 필드 장치의 시험 구성, 동적 조건 및 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-5:2024 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-5부: 특정 요건 - IEC 61784-1, CP 3/2에 따른 인터페이스를 장착한 필드 장치의 시험 구성, 동적 조건 및 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-5:2014 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-5부: 특정 요건 - IEC 61784-1, CP3/2에 따른 인터페이스를 장착한 필드 장치의 시험 구성, 동적 조건 및 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9811:2019 |
산업·과학·의료용(ISM) 기기 - 무선주파수 방해특성 - 허용기준 및 측정방법
Exception: - 30 m 측정 거리 기기 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ |
소재지 |
| EN IEC 61326-2-4:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61000-3-3:2013+A2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection
Exception: - 3 Phase equipment |
Power : single-phase 16 A 미만 |
소재지 |
| EN IEC 55014-2:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 230 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| EN 55014-2:2015 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 230 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| AS CISPR 15:2017 |
Limits and methods of measurement of radio disturbance characteristics lighting and similar equipment
Exception: - 4.2 insertion loss |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 300 ㎒ |
소재지 |
| AS/NZS CISPR 15:2025 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
Exception: - 4.2 insertion loss |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 300 ㎒ |
소재지 |
| KS C 9610-4-8:2022 |
전자기적합성(EMC) - 제4-8부 : 시험 및 측정기술 - 전원주파수 자계 내성시험 |
Magnetic Field : Max 1000 A/m |
소재지 |
| EN 60601-2-37:2008+A1:2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 60601-2-37:2024 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| AS CISPR 11:2017+A1:2020 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ |
소재지 |
| AS/NZS CISPR 11:2024 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ |
소재지 |
| AS CISPR 11:2017 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ |
소재지 |
| IEC 60601-2-47:2012 |
Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 61326-2-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 55011:2016+A1:2017+A11:2020 |
Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 kHz ~ 18 ㎓ |
소재지 |
| EN 55011:2016+A2:2021 |
Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 kHz ~ 18 ㎓ |
소재지 |
| EN IEC 55011:2025 |
Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 kHz ~ 18 ㎓ |
소재지 |
| EN 55035:2017+A11:2020 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements
Exception: - Broadband impulsive / Isolated impulse noise disturbance |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) RS (spot test): 3 V/m (1 800 MHz, 2 600 MHz, 3 500 MHz, 5 000 MHz) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 1 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61000-4-11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
Voltage Dip: 0 % ~ 100 % |
소재지 |
| EN IEC 61000-4-11:2020 |
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase |
Voltage Dip : 0 % ~ 100 % |
소재지 |
| EN IEC 61000-4-3:2020 |
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
Field Strength: Max 28 V/m (80 ㎒ ~ 3 ㎓): Max 28 V/m (3 ㎓ ~ 6 ㎓): Max 10 V/m |
소재지 |
| EN 61000-4-3:2006+A1:2008+A2:2010 |
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
Field Strength: Max 28 V/m (80 ㎒ ~ 3 ㎓): Max 28 V/m (3 ㎓ ~ 6 ㎓): Max 10 V/m |
소재지 |
| J 55014-1 (H27) |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE: 9 ㎑ ~ 30 ㎒ DP: 30 ㎒ ~ 300 ㎒ RE: 30 ㎒ ~ 1 ㎓ |
소재지 |
| IEC 61000-6-4:2018 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| IEC 60601-1-2:2007 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-1-2:2014+AMD1:2020 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61326-2-4:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| S2-W-5:2024 |
기계․기구 등에 관한 공통 기술기준 [전자파분야] |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 18 GHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 000 MHz) 3 V/m (1 400 MHz ~ 6 000 MHz) EFT: ±2 kV SURGE : ±2 kV CS : 10 V (150 kHz ~ 80 MHz) V-DIP: 0 % ~ 100 % |
소재지 |
| S2-W-5:2017 |
기계․기구 등에 관한 공통 기술기준 [전자파분야] |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 215 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 000 MHz) 3 V/m (1 400 MHz ~ 2 000 MHz) 1 V/m (2 000 MHz ~ 2 700 MHz) EFT: ±2 kV SURGE : ±2 kV CS : 10 V (150 kHz ~ 80 MHz)\ V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-45:2011+A1:2015 |
Medical electrical equipment - Part 2-45: Particular requirements for basic safety and essential performance of mammographic X-ray equipment and mammomagraphic stereotactic devices |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-45:2011+A1:2015+A2:2024 |
Medical electrical equipment - Part 2-45: Particular requirements for basic safety and essential performance of mammographic X-ray equipment and mammomagraphic stereotactic devices |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-45:2011+AMD1:2015+AMD2:2022 |
Medical electrical equipment - Part 2-45: Particular requirementsfor basic safety and essential performance of mammographic X-ray equipment and mammomagraphic stereotactic devices |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9610-3-3:2023 |
전자파적합성(EMC) - 제3-3부: 허용기준 - 공공 저압 배전망에 사용하는 기기의 플리커와 전압변동에 대한 허용기준 (상당 16 A 이하 기기)
Exception: - 3 상 장비 |
Power : single-phase 16 A 미만 |
소재지 |
| EN IEC 61326-2-6:2025 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±15 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 000 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61326-2-5:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for devices with field bus interfaces according to IEC 61784-1 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
KS C 9040-2:2017 (MOD IEC 62040-2:2005) |
무정전전원장치(UPS) - 제2부:전자파적합성(EMC) 요구사항 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m |
소재지 |
| CISPR 11:2015+AMD1:2016+AMD2:2019 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 kHz ~ 18 ㎓ |
소재지 |
| IEC 61000-4-2:2008 |
Electromagnetic compatibility (EMC) - Part 4-2 : Testing and measurement techniques - Electrostatic discharge immunity test |
Max : ±30 ㎸ |
소재지 |
| IEC 61000-4-2:2025 |
Electromagnetic compatibility (EMC) - Part 4-2 : Testing and measurement techniques - Electrostatic discharge immunity test |
Max : ±30 ㎸ |
소재지 |
| EN IEC 61000-6-4:2019 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| IEC 61326-2-6:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61326-2-6:2025 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61326-2-5:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for field devices with field bus interfaces according to IEC 61784-1 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 62236-2:2006 |
철도용 전기 자기 적합성 - 제2부:전체 철도 시스템에서 외부로 나가는 방출 |
RE: 9 kHz ~ 1 ㎓ |
소재지 |
| KS C IEC 62236-2:2022 |
철도 적용 - 전자기 적합성 - 제2부: 전체 철도 시스템에서 외부로 나가는 방출 |
RE: 9 kHz ~ 1 ㎓ |
소재지 |
| EN 60601-2-5:2015 |
Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| AS/NZS CISPR 32:2015 |
Electromagnetic compatibility of multimedia equipment Emission requirements
Exception: - ERP: 1 GHz ~ 18 GHz - 3.1.7 DVB-S and ISDB of broadcast receiver equipment - 3.1.9 broadcast satellite outdoor system |
CE: 9 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| AS/NZS CISPR 32:2015+A1:2020 |
Electromagnetic compatibility of multimedia equipment Emission requirements
Exception: - ERP: 1 GHz ~ 18 GHz - 3.1.7 DVB-S and ISDB of broadcast receiver equipment - 3.1.9 broadcast satellite outdoor system |
CE: 150 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| KS C IEC 62236-3-2:2006 |
철도용 전기 자기 적합성 - 제3-2부: 철도 차량 - 장치 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 000 MHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±1.8 kV CS: 10 V (150 kHz ~ 80 MHz) V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 62236-3-2:2022 |
철도 적용 - 전자기 적합성 - 제3-2부: 철도 차량 - 기기 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 000 MHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±1.8 kV CS: 10 V (150 kHz ~ 80 MHz) V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 62236-3-2:2018 |
Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 000 MHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±1.8 kV CS: 10 V (150 kHz ~ 80 MHz) V-DIP: 0 % ~ 100 % |
소재지 |
| KRS CS 0003-24(R):2024 |
철도차량 차상신호장치 시험방법 4.3 시험 아. 전기자기 적합성 시험 IEC 62236-3-2 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 000 MHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±1.8 kV CS: 10 V (150 kHz ~ 80 MHz) V-DIP: 0 % ~ 100 % |
소재지 |
| KRS CS 0003-21(R):2021 |
철도차량 차상신호장치 시험방법 4.3 시험 아. 전기자기 적합성 시험 IEC 62236-3-2 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 000 MHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±1.8 kV CS: 10 V (150 kHz ~ 80 MHz) V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61000-4-2:2009 |
Electromagnetic compatibility (EMC) - Part 4-2 : Testing and measurement techniques - Electrostatic discharge immunity test |
Max : ±30 ㎸ |
소재지 |
| IEC 61326-2-2:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 55032:2015+A11:2020 |
Electromagnetic compatibility of multimedia equipment Emission requirements
Exception: - ERP: 1 GHz ~ 18 GHz - DVB-S and ISDB of broadcast receiver equipment - broadcast satellite outdoor system |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| KS C 9040-2:2022 |
무정전전원장치(UPS) - 제2부:전자파적합성(EMC) 요구사항 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m \(80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m |
소재지 |
| KS C 9040-2:2025 |
무정전전원장치(UPS) - 제2부:전자파적합성(EMC) 요구사항 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m \(80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m |
소재지 |
| EN IEC 61326-2-6:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±15 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 000 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61326-2-6:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61000-3-3:2013+A1:2019 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection
Exception: - 3 Phase equipment |
Power : single-phase 16 A 미만 |
소재지 |
| EN 61000-3-3:2013/A2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection
Exception: - 3 Phase equipment |
Power : single-phase 16 A 미만 |
소재지 |
| EN IEC 61800-3:2023 |
Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61000-4-5:2014+A1:2017 |
Electromagnetic compatibility (EMC) - Part 4-5 : Testing and measurement techniques - Surge immunity test |
Pules Voltage : ±6 ㎸ |
소재지 |
| CISPR 14-2:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 230 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61000-3-3:2013/AMD2:2021 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| IEC 61000-3-3:2013/AMD1:2017 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| KS C 9610-4-3:2022 |
전자기적합성(EMC) - 제4-3부:시험 및 측정기술 - 방사 무선주파수 전기자기장 내성 시험 |
Field Strength: Max 28 V/m (80 ㎒ ~ 3 ㎓): Max 28 V/m (3 ㎓ ~ 6 ㎓): Max 10 V/m |
소재지 |
| KS C 9610-4-3:2017 |
전자기적합성(EMC) - 제4-3부:시험 및 측정기술 - 방사 무선주파수 전기자기장 내성 시험 |
Field Strength: Max 28 V/m (80 ㎒ ~ 3 ㎓): Max 28 V/m (3 ㎓ ~ 6 ㎓): Max 10 V/m |
소재지 |
| IEC 61000-4-4:2012 |
Electromagnetic compatibility (EMC) - Part 4-4 : Testing and measurement techniques - Electrical fast transient/burst immunity test |
Pules Voltage : Max ±4 ㎸ |
소재지 |
| EN 61000-4-4:2012 |
Electromagnetic compatibility (EMC) - Part 4-4 : Testing and measurement techniques - Electrical fast transient/burst immunity test |
Pules Voltage : Max ±4 ㎸ |
소재지 |
| EN IEC 61326-2-2:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61326-2-2:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61326-2-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61326-2-3:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| CISPR 14-1:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
Exception: - Clause 4.3.3.5 Electric fence |
CE: 9 ㎑ ~ 30 ㎒ DP: 30 ㎒ ~ 300 ㎒ RE: 9 ㎑ ~ 6 ㎓ |
소재지 |
| EN 50130-4:2011/A1:2014 |
Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems |
ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 100 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-3:2014 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-3부: 특정 요건 - 통합 또는 원격 신호 조정 기능이 있는 변환기에 대한 시험 구성, 운영 조건, 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-3:2019 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-3부: 특정 요건 - 통합 또는 원격 신호 조정 기능이 있는 변환기에 대한 시험 구성, 운영 조건, 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-3:2024 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-3부: 특정 요건 - 통합 또는 원격 신호 조정 기능이 있는 변환기에 대한 시험 구성, 운영 조건, 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 61800-3:2018 |
Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| EN 55032:2015/A1:2020 |
Electromagnetic compatibility of multimedia equipment Emission requirements
Exception: - ERP: 1 GHz ~ 18 GHz - DVB-S and ISDB of broadcast receiver equipment - broadcast satellite outdoor system |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| IEC 60601-2-54:2022 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 61204-3:2018 |
Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V, 0.15 ㎒ ~ 80 ㎒ V-DIP: 0 % ~ 100 % |
소재지 |
KS C 9610-6-4:2022 (MOD IEC 61000-6-4:2018) |
전자파적합성(EMC) - 제6-4부:일반 표준 - 산업 환경에서의 전자파 방출 표준 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
EN IEC 61000-6-2:2019 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61000-6-2:2016 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9610-6-1:2019 |
전자파적합성(EMC) - 제6-1부: 일반표준 - 주거, 상업 및 경공업 환경에서 사용하는 기기의 전자파 내성 표준 |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
EN IEC 61000-6-1:2019 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9832:2019 |
멀티미디어 기기 전자파 방해 시험방법
Exception: - 3.7 방송수신기기의 DVB-S 및 ISDB - 3.24 위성방송옥외 시스템 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| KS C 9832:2024 |
멀티미디어 기기 전자파 방해방지 시험방법
Exception: - 3.7 방송수신기기의 DVB-S 및 ISDB - 3.24 위성방송옥외 시스템 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| KS C 9832:2023 |
멀티미디어 기기 전자파 방해 시험방법
Exception: - 3.7 방송수신기기의 DVB-S 및 ISDB - 3.24 위성방송옥외 시스템 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| CISPR 32:2015+AMD1:2019 |
Electromagnetic compatibility of multimedia equipment Emission requirements
Exception: - ERP: 1 GHz ~ 18 GHz - 3.1.7 DVB-S and ISDB of broadcast receiver equipment - 3.1.9 broadcast satellite outdoor system |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| QCVN 118:2018/BTTTT |
National technical regulation on Electromagnetic compatibility of multimedia equipment - Emission requirements |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| EN 60601-2-63:2015/A2:2021 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-63:2015 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| CISPR 11:2024 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
Exception: - Test distance 30 m |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ |
소재지 |
| KS X 3125:2024 |
특정 소출력 무선기기 전자파적합성 시험방법
Exception: - ABT |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
KS X 3125:2020 (MOD EN 301 489-3:2013) |
특정 소출력 무선기기 전자파적합성 시험방법
Exception: - ABT |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
KS C 9610-4-2:2017 (MOD IEC 61000-4-2) |
전자기적합성(EMC) - 제4-2부:시험 및 측정기술 - 정전기 방전 내성시험 |
Max : ±30 ㎸ |
소재지 |
| KS C 9610-4-2:2022 |
전자기적합성(EMC) - 제4-2부:시험 및 측정기술 - 정전기 방전 내성시험 |
Max : ±30 ㎸ |
소재지 |
| IEC 80601-2-49:2011 |
Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitors |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 80601-2-49:2018 |
Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitors |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 80601-2-49:2018+AMD1:2024 CSV |
Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitors |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9800-3:2022 |
가변속 전력구동기기 - 제3부: 전자파적합성(EMC) 요구사항 및 시험방법 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9835:2019 |
멀티미디어 기기 전자파 내성 시험방법 |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) RS (spot test): 3 V/m (1 800 MHz, 2 600 MHz, 3 500 MHz, 5 000 MHz) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 1 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-22:2019+A1:2026 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-22:2019 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-18:2015 |
Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| ETSI EN 301 489-3 V2.3.2 (2023-01) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonised Standard for ElectroMagnetic Compatibility
Exception: - ABT |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| ETSI EN 301 489-3 V2.1.1 (2019-03) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz
Exception: - ABT |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| QCVN 96:2015/BTTTT |
National Technical regulation on electromagnetic compatibility for Short Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| KS X 3124:2024 |
무선설비기기류의 공통 전자파적합성 시험방법
Exception: - Car(TI) equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
KS X 3124:2020 (MOD EN 301 489-1:2017) |
무선설비기기류의 공통 전자파적합성 시험방법
Exception: - Car(TI) equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61800-3:2022 |
Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 55015:2019+A11:2020 |
Limits and methods of measurement of radio disturbance characteristics lighting and similar equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 1 000 ㎒ |
소재지 |
| EN 61326-2-4:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 60601-2-28:2019 |
Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9610-3-2:2023 |
전자기적합성(EMC) - 제3-2부:허용기준 - 고조파 전류의 허용기준 (상당 입력 전류 16 A 이하 기기)
Exception: - 3 상 장비 |
Power : single-phase 16 A 미만 |
소재지 |
| EN IEC 62040-2:2018 |
Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
Exception: - 7.4 Immunity to low-frequency signals |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 62040-2:2016 |
Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 61326-2-5:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5: Particular requirements - Test configurations, operational conditions and performance criteria for devices with field bus interfaces according to IEC 61784-1 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9815:2019 |
조명기기 및 유사기기의 무선 방해 특성의 허용기준 및 측정 방법 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 1 000 ㎒ |
소재지 |
| KS C IEC 62236-4:2022 |
철도 적용 - 전자기 적합성 - 제4부: 신호 및 통신 기기의 방출 및 내성
Exception: - 1.5 펄스 자기장 - 부속서 A 견인 주파수 시험(선로-접지) |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±2 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| ETSI EN 301 489-17 V3.1.1 (2017-02) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| ETSI EN 301 489-17 V3.3.1 (2024-09) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband and Wideband Data Transmission Systems; Harmonised Standard for ElectroMagnetic Compatibility |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| ETSI EN 301 489-17 V3.2.4 (2020-09) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonised Standard for ElectroMagnetic Compatibility |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| QCVN 112:2017/BTTTT |
National technical regulation on general electromagnetic compatibility for radio broadband data transmission equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 62236-1:2006 |
철도용 전기 자기 적합성 - 제1부: 일반 사항 |
일반 사항 |
소재지 |
| KS C CISPR 24:2014 |
전기자기적합성(EMC) - 정보기기(ITE)의 전기자기내성 시험방법 및 측정의 한계값 |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 1 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-4:2011/A1:2019 |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-18:2009 |
Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-10:2015+A1:2016 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and musclestimulators |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-10:2012+AMD1:2016 |
Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and musclestimulators |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 62236-4:2006 |
철도용 전기 자기 적합성 - 제4부 : 신호 처리 및 통신 장치의 방출 및 내성
Exception: - 1.5 펄스 자기장 - 부속서 A 견인 주파수 시험(선로-접지) |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±2 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KRS SG 0068-23 (R) |
승강장 안전문 설비 Platform Screen Door System |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±2 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KS C IEC62236-5:2022 |
철도 적용 - 전자기 적합성 - 제5부: 고정 전력공급 설비와 기기의 방출 및 내성
Exception: 3.2 감쇠 발진 전압 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KS C IEC 62236-5:2018 |
철도 적용 - 전자기 적합성 - 제5부: 고정 전력공급 설비와 기기의 방출 및 내성
Exception: 3.2 감쇠 발진 전압 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KRS CS 0003-13 |
철도차량 차상신호장치 시험방법 3.2.1.4 전자기 적합성시험 (EMC) IEC 62236-3-2 |
전도: 150 kHz ~ 30 MHz 방사: 30 MHz ~ 6 000 MHz THD: 50 Hz to 2 kHz 정전기: ±8 kV 방사성 RF 전자기장: 10 V/m (80 MHz ~ 800 MHz) 20 V/m (800 MHz ~ 1 000 MHz) 10 V/m (1 400 MHz ~ 2 000 MHz) 5 V/m (2 000 MHz ~ 2 700 MHz) 3 V/m (5 100 MHz ~ 6 000 MHz) 버스트: ±2 kV 서지 : ±2 kV 전도성 RF 전자기장 : 10 V (150 kHz ~ 80 MHz) |
소재지 |
| EN IEC 61326-1:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS X 3126:2024 |
무선 데이터 통신 시스템용 특정 소출력 무선기기 전자파적합성 시험방법 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
KS X 3126:2020 (MOD EN 301 489-17:2009) |
무선 데이터 통신 시스템용 특정 소출력 무선기기 전자파적합성 시험방법 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-1-2:2007/AC:2010 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A 이하 ESD: CD ±6 ㎸, AD ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 3 A/m V-DIP : 0 % ~ 100 % |
소재지 |
| EN 60601-1-2:2015/A1:2021 |
Medical electrical equipment - Part 1-2 : general requirements for basic safety and essential performance - Collateral Standard : Electromagnetic disturbances - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A 이하 ESD: CD ±6 ㎸, AD ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 3 A/m V-DIP : 0 % ~ 100 % |
소재지 |
| IEC 61000-4-8:2009 |
Electromagnetic compatibility (EMC) - Part 4-8 : Testing and measurement techniques - Power frequency magnetic field immunity test |
Magnetic Field : Max 1000 A/m |
소재지 |
| KS C IEC 62236-4:2018 |
철도 적용 - 전자기 적합성 - 제4부: 신호 및 통신 기기의 방출 및 내성
Exception: - 1.5 펄스 자기장 - 부속서 A 견인 주파수 시험(선로-접지) |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±2 kV SURGE: ±2 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
KS C 9610-3-2:2020 (MOD IEC 61000-3-2:2009) |
전자기적합성(EMC) - 제3-2부:허용기준 - 고조파 전류의 허용기준 (상당 입력 전류 16 A 이하 기기)
Exception: - 3상 장비 |
Power : single-phase 16 A 미만 |
소재지 |
| KS C IEC 61326-2-4:2014 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-4부: 특정 요건 - IEC 61557-8에 따른 절연 감시 장치와 IEC 61557-9에 따른 절연 고장 탐지 장치에 대한 시험 구성, 동작 조건 및 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61000-4-8:2010 |
Electromagnetic compatibility (EMC) - Part 4-8 : Testing and measurement techniques - Power frequency magnetic field immunity test |
Magnetic Field : Max 1000 A/m |
소재지 |
| KS C CISPR 24:2019 |
전기자기적합성(EMC) - 정보기기(ITE)의 전기자기내성 시험방법 및 측정의 한계값 |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 1 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61000-3-2:2018+AMD1:2020+AMD2:2024 CSV |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| IEC 61000-3-2:2018 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| IEC 60601-2-65:2012+AMD1:2017+AMD2:2021 |
Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-65:2012+AMD1:2017 |
Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-65:2013/A2:2021 |
Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-65:2013 |
Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KRS SG 0055-14 (R) |
복선 자동폐색제어장치 4.2.2 시험의 방법 6) 전기자기적합성 시험 IEC 62236-4 |
전도: 150 kHz ~ 30 MHz 방사: 30 MHz ~ 6 000 MHz 정전기: ±8 kV 방사성 RF 전자기장: 10 V/m (80 MHz ~ 800 MHz) 20 V/m (800 MHz ~ 1 000 MHz) 10 V/m (1 400 MHz ~ 2 000 MHz) 5 V/m (2 000 MHz ~ 2 700 MHz) 3 V/m (5 100 MHz ~ 6 000 MHz) 버스트: ±2 kV 서지: ±2 kV 전도성 RF 전자기장: 10 V (150 kHz ~ 80 MHz) 전원주파수자계: 300 A/m |
소재지 |
| KRS SG 0054-14 (R) |
단선 자동폐색제어장치 4.2.2 시험의 방법 6) 전기자기적합성 시험 IEC 62236-4 |
전도: 150 kHz ~ 30 MHz 방사: 30 MHz ~ 6 000 MHz 정전기: ±8 kV 방사성 RF 전자기장: 10 V/m (80 MHz ~ 800 MHz) 20 V/m (800 MHz ~ 1 000 MHz) 10 V/m (1 400 MHz ~ 2 000 MHz) 5 V/m (2 000 MHz ~ 2 700 MHz) 3 V/m (5 100 MHz ~ 6 000 MHz) 버스트: ±2 kV 서지: ±2 kV 전도성 RF 전자기장: 10 V (150 kHz ~ 80 MHz) 전원주차수자계: 300 A/m |
소재지 |
| CISPR 35:2016 |
Electromagnetic compatibility of multimedia equipment - Immunity requirements
Exception: - Broadband impulsive / Isolated impulse noise disturbance |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) RS (spot test): 3 V/m (1 800 MHz, 2 600 MHz, 3 500 MHz, 5 000 MHz) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 1 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| AS/NZS 61000.6.3:2021 |
Electromagnetic compatibility (EMC) Part 6.3: Generic standards - Emission standard for equipment in residential environments (IEC 61000–6–3:2020 (ED 3.0) MOD) |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| AS CISPR 14.1:2018 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE: 150 ㎑ ~ 30 ㎒ DP: 30 ㎒ ~ 300 ㎒ RE: 30 ㎒ ~ 1 ㎓ |
소재지 |
| EN 61326-2-1:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61000-4-6:2023 |
Electromagnetic compatibility (EMC) - Part 4-6 : Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CS: Max 10 V (0.15 ㎒ – 230 ㎒) |
소재지 |
KS C 9610-3-3:2020 (MOD IEC 61000-3-3:2013) |
전자파적합성(EMC) - 제3-3부: 허용기준 - 공공 저압 배전망에 사용하는 기기의 플리커와 전압변동에 대한 허용기준 (상당 16 A 이하 기기)
Exception: - 3 상 장비 |
Power : single-phase 16 A 미만 |
소재지 |
| IEC 60601-2-45:2011+AMD1:2015 |
Medical electrical equipment - Part 2-45: Particular requirementsfor basic safety and essential performance of mammographic X-ray equipment and mammomagraphic stereotactic devices |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61204-3:2016 |
Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
CE: 0.15 ㎒ ~ 30 ㎒ RE, RFI: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 1 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61326-1:2020 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 61326-2-3:2021 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC61326-1:2008 |
계측제어 및 실험실 용도를 위한 전기기기 - 전자기 적합성 요구사항 - 제1부:일반 요구사항 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-1:2023 |
계측제어 및 실험실 용도를 위한 전기기기 - 전자기 적합성 요구사항 - 제1부:일반 요구사항 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 12015:2020 |
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
Exception: - EN IEC 61000-3-2 (3-phase) - EN 61000-3-3 (3-phase) - IEC 61000-3-11 - EN 61000-3-12 |
CE, Click : 150 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 1 ㎓ EN IEC 61000-3-2 (1-phase) EN 61000-3-3 (1-phase) |
소재지 |
| EN IEC 61000-4-6:2023 |
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CS: Max 10 V (0.15 ㎒ – 230 ㎒) |
소재지 |
| IEC 61000-4-6:2013 |
Electromagnetic compatibility (EMC) - Part 4-6 : Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CS: Max 10 V (0.15 ㎒ – 230 ㎒) |
소재지 |
| IEC 61000-3-2:2018/AMD1:2020 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| IEC 61000-3-2:2018/AMD2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| IEC 61000-6-3:2026 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential locations |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| IEC 61000-6-3:2020 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| IEC 60601-2-5:2009 |
Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
KS C 9610-4-11:2020 (MOD IEC 61000-4-11:2004) |
전자파적합성(EMC) - 제4-11부: 시험 및 측정 기술 - 전압 강하, 순간 정전, 전압 변동 내성 시험 |
Voltage Dip: 0 % ~ 100 % |
소재지 |
KS C 9610-4-4:2020 (MOD IEC 61000-4-4:2012) |
전자파적합성(EMC) - 제4-4부: 시험 및 측정 기술 - 전기적 빠른 과도현상, 버스트 내성 시험 |
Pules Voltage : Max ±4 ㎸ |
소재지 |
| KS C 9610-6-2:2019 |
전자파적합성(EMC) - 제6-2부: 일반표준 - 산업 환경에서 사용하는 기기의 전자파 내성 표준 |
ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-4:2010+AMD1:2018 |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61000-4-3:2020 |
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
Field Strength: Max 28 V/m (80 ㎒ ~ 3 ㎓): Max 28 V/m (3 ㎓ ~ 6 ㎓): Max 10 V/m |
소재지 |
| AS/NZS 61000.6.3:2012 |
Electromagnetic compatibility (EMC) Part 6.3: Generic standards – Emission standard for residential, commercial and light-industrial environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| KS C IEC 61204-3:2023 |
저전압 직류 전원 장치 – 제3부:전기 자기 적합성(EMC) |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V, 0.15 ㎒ ~ 80 ㎒ V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC61204-3:2003 |
저전압 직류 전원 장치 – 제3부:전기 자기 적합성(EMC) |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V, 0.15 ㎒ ~ 80 ㎒ V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9610-4-5:2023 |
전자파적합성(EMC) - 제4-5부: 시험 및 측정 기술 - 서지 내성 시험 |
Pules Voltage: ±6 ㎸ |
소재지 |
| KS C 9814-1:2022 |
전자파적합성(EMC) - 가정용 전기 기기, 전동 공구 및 유사 기기의 요구 사항 - 제1부: 방출 |
CE: 150 ㎑ ~ 30 ㎒ DP: 30 MHz ~ 300 MHz RE: 30 ㎒ ~ 1 ㎓ |
소재지 |
| KS C IEC 62236-5:2022 |
철도 적용 - 전자기 적합성 - 제5부: 고정 전력공급 설비와 기기의 방출 및 내성
Exception: 3.2 감쇠 발진 전압 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KRS SG 0036-25(R):2025 |
궤도회로 기능감시장치 4.2.2 시험 방법 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KRS SG 0036-22(R):2022 |
궤도회로 기능감시장치 4.2.2 시험 방법 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KRS SG 0033-24(R):2024 |
유절연 가청주파수(AF) 궤도회로 4.2.2 시험의 방법 5) 전기자기적합성 시험 IEC 62236-4 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KRS SG 0033-21(R):2021 |
유절연 가청주파수(AF) 궤도회로 4.2.2 시험의 방법 6) 전기자기적합성 시험 IEC 62236-4 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KRS SG 0015-23(R):2023 |
전자연동장치 4.7.3 전기자기 적합성(EMC) 시험 시험 방법 및 기준은 KRS SG 0067에 따른다 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| IEC 62236-5 :2018 |
Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| KS C IEC 62236-5:2006 |
철도용 전기 자기 적합성 - 제5부:고정 전력 공급 설비와 장치의 방출 및 내성
Exception: 3.2 감쇠 발진 전압 |
CE: 150 kHz ~ 30 MHz RE: 30 MHz ~ 1 000 MHz ESD: ±8 kV RS: 10 V/m (80 MHz ~ 1 GHz) 20 V/m (800 MHz ~ 960 MHz) 20 V/m (1 400 MHz ~ 2 000 MHz) EFT: ±4 kV SURGE: ±4 kV CS: 10 V (150 kHz ~ 80 MHz) Magnetic: 300 A/m |
소재지 |
| IEC 61000-6-1:2016 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KN 50/KN 51:2019 |
전기철도기기류의 전자파적합성 시험방법
Exception: - 감쇄진동전압 IEC 61000-4-12 |
전도 : 150 kHz ~ 30 MHz 방사 : 30MHz ~ 1 000 MHz 정전기 : ±8 kV 방사성 RF 전자기장 : 10 V/m (80 MHz ~ 800 MHz) 20 V/m (800 MHz ~ 1 000 MHz) 10 V/m (1 400 MHz ~ 2 000 MHz) 5 V/m (2 000 MHz ~ 2 700 MHz) 3 V/m (5 100 MHz ~ 6 000 MHz) 버스트 : ±4 kV 서지 : ±4 kV 전도성 RF 전자기장 : 10 V (150 kHz ~ 80 MHz) 전원주파수자계 : 300 A/m |
소재지 |
| ETSI EN 301 489-1 V2.2.3 (2019-11) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for ElectroMagnetic Compatibility
Exception: - Car(TI) equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| ETSI EN 301 489-1 V2.1.1 (2017-02) |
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements
Exception: - Car(TI) equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| QCVN 18:2022/BTTTT |
National technical regulation on Electromagnetic Compatibility for Radio Equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT/B: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 62236-1:2022 |
철도 적용 - 전자기 적합성 - 제1부: 일반사항 |
일반 사항 |
소재지 |
| EN IEC 55014-1:2021 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE: 9 ㎑ ~ 30 ㎒ DP: 30 ㎒ ~ 300 ㎒ RE: 9 ㎑ ~ 6 ㎓ |
소재지 |
| EN 55014-1:2017+A11:2020 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
CE: 9 ㎑ ~ 30 ㎒ DP: 30 ㎒ ~ 300 ㎒ RE: 9 ㎑ ~ 1 ㎓ |
소재지 |
| KRS SG 0033-14 (R) |
유절연가청주파수(AF)궤도회로 4.2.2 시험의 방법 6) 전기자기적합성 시험 IEC 62236-4 |
전도: 150 kHz ~ 30 MHz 방사: 30 MHz ~ 6 000 MHz 정전기: ±8 kV 방사성 RF 전자기장: 10 V/m (80 MHz ~ 800 MHz) 20 V/m (800 MHz ~ 1 000 MHz) 10 V/m (1 400 MHz ~ 2 000 MHz) 5 V/m (2 000 MHz ~ 2 700 MHz) 3 V/m (5 100 MHz ~ 6 000 MHz) 버스트: ±2 kV 서지: ±2 kV 전도성 RF 전자기장: 10 V (150 kHz ~ 80 MHz) 전원주파수자계 : 300 A/m |
소재지 |
KS C 9610-4-6:2020 (MOD IEC 61000-4-6:2013) |
전자파적합성(EMC) - 제4-6부: 시험 및 측정 기술 - 전도성 RF 전자기장 내성 시험 |
CS: Max 10 V (0.15 ㎒ – 230 ㎒) |
소재지 |
| EN 61000-4-6:2014 |
Electromagnetic compatibility (EMC) - Part 4-6 : Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CS: Max 10 V (0.15 ㎒ – 230 ㎒) |
소재지 |
| EN IEC 61547:2023 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT/Burst: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 MHz ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61547:2009 |
Equipment for general lighting purposes - EMC immunity requirements |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT/Burst: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 MHz ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 61000-3-2:2019/A2:2024 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| EN IEC 61000-3-2:2019/A1:2021 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
| EN 60601-2-4:2011 |
Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-63:2012+AMD1:2017+AMD2:2021 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-54:2009/A2:2019 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-54:2009+A1:2015 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 55024:2010/AMD1:2015 |
Information technology equipment - Immunity characteristics - Limits and methods of measurement |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 1 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-4:2024 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-4부: 특정 요건 - IEC 61557-8에 따른 절연 감시 장치와 IEC 61557-9에 따른 절연 고장 탐지 장치에 대한 시험 구성, 동작 조건 및 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-4:2019 |
측정, 제어, 실험용 전기장치 - EMC 요건 - 제2-4부: 특정 요건 - IEC 61557-8에 따른 절연 감시 장치와 IEC 61557-9에 따른 절연 고장 탐지 장치에 대한 시험 구성, 동작 조건 및 성능 기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| AS 61000.6.4:2020 |
Electromagnetic compatibility (EMC) Part 6.4:Generic standards - Emission standard for industrial environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| AS/NZS 61000.6.4:2012 |
Electromagnetic compatibility (EMC) Part 6.4:Generic standards - Emission standard for industrial environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| KS C IEC 61326-2-1:2023 |
계측제어 실험실 용도의 전기기기 - EMC 요구사항 - 제2-1부:특수 요구사항 - EMC 비해당 분야의 민감한 시험기기/계측기기의 시험구성, 동작조건 및 성능 판정기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C IEC 61326-2-1:2008 |
계측제어 실험실 용도의 전기기기 - EMC 요구사항 - 제2-1부:특수 요구사항 - EMC 비해당 분야의 민감한 시험기기/계측기기의 시험구성, 동작조건 및 성능 판정기준 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 61000-3-2:2019 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Exception: - 3 Phase quipment |
Power : single-phase 16 A 미만 |
소재지 |
KS C 9610-4-8:2017 (MOD IEC 61000-4-8) |
전자기적합성(EMC) - 제4-8부 : 시험 및 측정기술 - 전원주파수 자계 내성시험 |
Magnetic Field : Max 1000 A/m |
소재지 |
| KS C 9547:2023 |
일반 조명기기 - 전기자기적합성(EMC) 내성 요구사항 |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT/Burst: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 MHz ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
KS C 9547:2020 (MOD IEC 61547:2009) |
일반 조명기기 - 전기자기적합성(EMC) 내성 요구사항 |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 1 000 ㎒) EFT/Burst: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 MHz ~ 80 ㎒) Magnetic: 3 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| CISPR 15:2018+AMD1:2024 CSV |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 1 000 ㎒ |
소재지 |
| CISPR 15:2018 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 1 000 ㎒ |
소재지 |
| EN 61000-6-3:2007+A1:2011 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| EN IEC 61000-6-3:2026 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| EN IEC 61000-6-3:2021 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| VCCI-CISPR 32:2016 |
Technical Requirements |
CE: 9 ㎑ ~ 30 ㎒ RE: 30 ㎒ ~ 6 ㎓ |
소재지 |
| EN IEC 60601-2-54:2024 |
Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61000-4-5:2014/AMD1:2017 |
Electromagnetic compatibility (EMC) - Part 4-5 : Testing and measurement techniques - Surge immunity test |
Pules Voltage : ±6 ㎸ |
소재지 |
| IEC 60601-2-63:2012+AMD1:2017 |
Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-1-2:2014+AMD1:2020 CSV |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-1-2:2014 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| CISPR 24:2010 +A1:2015 |
Information technology equipment - Immunity characteristics - Limits and methods of measurement |
ESD: ±8 ㎸ RS: 3 V/m, 80 ㎒ ~ 1 000 ㎒ EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V, 0.15 ㎒ ~ 80 ㎒ Magnetic: 1 A/m V-DIP: 0 % ~ 100 % |
소재지 |
KS C 9814-2:2022 (MOD CISPR 14-2:2020) |
전자파적합성(EMC) - 가정용 전기 기기, 전동 공구 및 유사 기기의 요구 사항 - 제2부: 내성 |
ESD: ±8 ㎸ RS: 3 V/m (80 ㎒ ~ 6 000 ㎒) EFT: ±1 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 230 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| EN IEC 60601-2-22:2020 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 60601-2-22:2013 |
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61326-1:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KRS SG 0067-14 |
지상 신호제어설비 시험방법 3.2.3.4 전기자기 적합성(EMC) 시험 IEC 62236-4 |
전도: 150 kHz ~ 30 MHz 방사: 30 MHz ~ 6 000 MHz 정전기: ±8 kV 방사성 RF 전자기장: 10 V/m (80 MHz ~ 800 MHz) 20 V/m (800 MHz ~ 1 000 MHz) 10 V/m (1 400 MHz ~ 2 000 MHz) 5 V/m (2 000 MHz ~ 2 700 MHz) 3 V/m (5 100 MHz ~ 6 000 MHz) 버스트: ±2 kV 서지: ±2 kV 전도성 RF 전자기장: 10 V (150 kHz ~ 80 MHz) 전원주파수자계: 300 A/m |
소재지 |
| KS C 9610-6-3:2023 |
전자파적합성(EMC) - 제6-3부: 일반표준 - 주거용, 상업용 및 경공업 환경에서의 전자파 방출 표준 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
KS C 9610-6-3:2017 (MOD IEC 61000-6-3) |
전자파적합성(EMC) - 제6-3부: 일반기준 - 주거용, 상업용 및 경공업 환경에서 사용하는 기기의 전자파 방해 표준 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 6 000 ㎒ |
소재지 |
| IEC 60601-2-37:2024 (Ed.3.0) |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 60601-2-37:2007+AMD1:2015 |
Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~ 390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KS C 9815:2023 |
조명기기 및 유사기기의 무선 방해 특성의 허용기준 및 측정 방법 |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 1 000 ㎒ |
소재지 |
KS C 9800-3:2017 (MOD IEC 61800-3) |
가변속 전력구동기기 - 제3부: 전자파적합성(EMC) 요구사항 및 시험방법 |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| IEC 61800-3:2017 |
Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 30 ㎒ ~ 1 000 ㎒ ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) V-DIP: 0 % ~ 100 % |
소재지 |
| EN 61326-2-3:2013 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
CE: 9 ㎑ ~ 30 ㎒ RE: 9 ㎑ ~ 18 ㎓ F/H: 16 A 미만 ESD: ±8 ㎸ RS: 10 V/m (80 ㎒ ~ 1 000 ㎒), 3 V/m (1 400 ㎒ ~ 2 000 ㎒), 1 V/m (2 000 ㎒ ~ 2 700 ㎒ EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 3 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % |
소재지 |
| KRS SG 0036-16 (R) |
궤도회로기능감시장치 4.2.2 시험의 방법 1) 전기자기 적합성(EMC) 시험 IEC 62236-4 |
전도: 150 kHz ~ 30 MHz 방사: 30 MHz ~ 6 000 MHz 정전기: ±8 kV 방사성 RF 전자기장: 10 V/m (80 MHz ~ 800 MHz) 20 V/m (800 MHz ~ 1 000 MHz) 10 V/m (1 400 MHz ~ 2 000 MHz) 5 V/m (2 000 MHz ~ 2 700 MHz) 3 V/m (5 100 MHz ~ 6 000 MHz) 버스트: ±2 kV 서지: ±2 kV 전도성 RF 전자기장: 10 V (150 kHz ~ 80 MHz) 전원주파수자계: 300 A/m |
소재지 |
| EN 60601-1-2:2015+AMD1:2021 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
CE: 0.15 ㎒ ~ 30 ㎒ RE: 0.15 ㎒ ~ 1 800 ㎒ F/H: 16 A 미만 ESD: CD ±8 ㎸, AD ±15 ㎸ RS: 27 V/m (380 ㎒ ~390 ㎒) RS: 10 V/m (80 ㎒ ~ 2 700 ㎒) RS: 28 V/m (430 ㎒ ~ 470 ㎒) RS: 28 V/m (800 MHz ~ 2.57 GHz) RS: 9 V/m (5.1 GHz ~ 5.8 GHz) EFT/B: ±2 ㎸ Surge: ±2 ㎸ CS: 10 V (0.15 ㎒ ~ 80 ㎒) Magnetic: 30 A/m V-DIP: 0 % ~ 100 % proximity magnetic fields : 9 ㎑ ~ 13.56 ㎒ |
소재지 |
KS C 9610-4-5:2020 (MOD IEC 61000-4-5:2014) |
전자파적합성(EMC) - 제4-5부: 시험 및 측정 기술 - 서지 내성 시험 |
Pules Voltage: ±6 ㎸ |
소재지 |
| ▶ 에너지효율 |
기후에너지환경부 고시 제2026-137호 (2026.5.27) |
효율관리기자재 운용규정
10. 전기밥솥 12. 선풍기 20. 어댑터·충전기 26. 텔레비전수상기 36. 전기레인지 37. 셋톱박스 42. 사이니지 디스플레이 44. 모니터 49. 컴퓨터 50. 복합기 54. 프린터 |
입력전압 : 최대 500 V 입력전류 : 최대 20 A |
소재지 |
기후에너지환경부 고시 제2026-25호 (2026.01.23) |
대기전력저감 프로그램 운용규정 3. 프린터 5. 복사기 6. 스캐너 8. 자동절전제어장치 10. 오디오 11. DVD플레이어 12. 라디오카세트 13. 전자레인지 15. 도어폰 16. 유무선전화기 17. 비데 20. 손건조기 21. 서버 23. 유무선공유기 |
입력전압 : 최대 500 V 입력전류 : 최대 20 A |
소재지 |